Technicolor NTSC-8
User’s Manual
Страница 1: ... 2016 Technicolor All Rights reserved Technicolor NTSC 8 User s Manual ...
Страница 2: ...nections 6 5 COM46 Software Requirements and Setup 8 6 NTSC 8 Setup 9 6 1 Setting up Multiple Chassis 10 6 2 Setting the Modulator Output Channels 13 6 3 Using Internal Attenuation 15 6 4 Carrier ON 17 6 5 Sharpness 17 6 6 Reset 17 6 7 Audio Level 18 6 8 Aspect Ratio 18 6 9 Verification of Streams 18 7 Software Upgrade 19 8 Status Lights 20 ...
Страница 3: ... FIGURE 11 ALTIP 11 FIGURE 12 CHASSIS DIPSWITCH 12 FIGURE 13 DIPSWITCH SETTINGS 12 FIGURE 14 OUTPUT CHANNEL SETTINGS 13 FIGURE 15 STATUS PAGE SHOWING SET CHANNELS 13 FIGURE 16 CHANGING OUTPUT CHANNEL BY MODULATOR 14 FIGURE 17 CHANNELS SET IN STATUS TABLE 15 FIGURE 18 SET ATTENUATION IN ALL MODULATORS 15 FIGURE 19 CHANGING ATTENUATION ON A SINGLE MODULATOR 16 FIGURE 20 CARRIER ON OFF 17 FIGURE 21 B...
Страница 4: ... w t e c h n i c o l o r c o m m c s Page 3 REVISION RECORD Revision Date Revision Editor Revision Description 1 11 3 16 Angelo Peruch Final Draft Approved 1 1 11 10 16 Angelo Peruch Revised chassis table ...
Страница 5: ...OM2000 system including remote management and is expandable to high definition for cost effective upgrades in the future System requires one RU of rack space Ventilation fans are rear mounted The front and rear areas of the NTSC 8 should be kept clear to ensure good airflow Included in the box is the NTSC 8 unit and power supply Note Technicolor only supports NTSC 8 installations when interfaced t...
Страница 6: ... c o l o r c o m m c s Page 5 3 Power Supply An external AC adaptor is included with the NTSC 8 The power adapter has a locking connector that clicks when properly seated as shown below in Figure 2 Figure 2 Power Supply ...
Страница 7: ...ts connected to a COM2000 system If more than one unit is to be connected a gigabit Ethernet switch not included is required between a chassis GbE port and the NTSC 8s Connect remote management directly to an unused COM360 GbE port or to the GiGe switch To RF Distribution Remote Management Device Figure 3 Physical Connections ...
Страница 8: ...insert the power cord into the Power port on the NTSC 8 as shown in Figure 4 When properly seated in the power port the plug will snap into place with an audible click To remove firmly pull back on the cover and remove the plug from the power port Figure 4 Power Supply Connections ...
Страница 9: ... Each COM46 card will stream eight channels to the NTSC 8 You will need to enter the IP address of the first NTSC 8 modulator in the COM46 advanced edit page as shown below in Figure 6 By default the NTSC 8 IP addresses are set to 192 168 5 1 8 Enter the IP address of the first modulator in the NTSC 8 in the NTSC8_IP field Click Submit Repeat in each COM46 card that is associated with a NTSC 8 uni...
Страница 10: ...ick on the NTSC tab as shown below in Figure 7 and Figure 8 Note the box to the right of each field in the Control section Checking this box will apply that setting to all modulators in the NTSC 8 Figure 7 COM46 Main Interface Page Figure 8 COM46 NTSC Tab Click box to apply setting to all modulators ...
Страница 11: ...ffect aspect ratio 0 4X3 1 16X9 a reset is required for this setting to take affect alternate Ip Sets an alternate IP address for each modulator tftpIP For software upgrade enter the IP of the COM46 card being used at a TFTP server tftpFilename For software upgrade enter the software filename uploaded to the COM46 6 1 Setting up Multiple Chassis Each channel or modulator within a NTSC 8 is assigne...
Страница 12: ...68 5 9 16 to the second NTSC 8 In the Control section of the NTSC user interface enter an IP address in the alternateIp field as shown in below in Figure 10 Figure 10 Enter Alternate IP Address Check the box to the right of the field to apply this setting to all modulators and click Submit You will see the new settings in the altIp column of the Status display as show in Figure 11 below Figure 11 ...
Страница 13: ...tch 1 Switch 2 Switch 3 Switch 4 Default IP MOD 1 0 DOWN DOWN DOWN DOWN 192 168 5 1 8 1 UP DOWN DOWN DOWN 192 168 5 9 16 2 DOWN UP DOWN DOWN 192 168 5 17 24 3 UP UP DOWN DOWN 192 168 5 25 32 4 DOWN DOWN UP DOWN 192 168 5 33 40 5 UP DOWN UP DOWN 192 168 5 41 48 6 DOWN UP UP DOWN 192 168 5 49 56 7 UP UP UP DOWN 192 168 5 57 64 8 DOWN DOWN DOWN UP 192 168 5 65 72 9 UP DOWN DOWN UP 192 168 5 73 80 10 ...
Страница 14: ...eld in the Control section To set all channels in the NTSC 8 to contiguous channels you can enter the first channel in the field and check the box to the right as shown in Figure 14 In the example below we will set channel outputs for as 2 9 Channels set in numerical order NTSC 8 supports RF channels 2 107 Figure 14 Output Channel Settings As shown below in Figure 15 the Status page now displays t...
Страница 15: ...r 6 slot 5 to channel 14 modulator 7 to 15 and modulator 8 to 16 Enter the IP address of modulator 6 it will now display at the top of the status table Figure 16 Changing Output Channel by Modulator Enter the desired channel in the field Do not check the box as you only want to change that modulator Click submit Repeat this process until RF outputs are set Enter modulator IP Modulator displayed En...
Страница 16: ...idual modulators to adjust the output power as necessary The default attenuation is set to 0 Maximum attenuation is 10dB To set attenuation for all modulators in a NTSC 8 enter the IP address of the first modulator in the NTSC 8 Modulator field and click Submit In this example we will attenuate all modulators 5 db Enter the attenuation value in the attenuation field and check the box as shown belo...
Страница 17: ...ck Submit Enter the attenuation value in the attenuation field do not check the box and click submit In this example we changed the attenuation value of modulator two slot1 to 8 dB The attenuation value for modulator 2 has been set to 8dB as shown in Figure 19 Figure 19 Changing Attenuation on a Single Modulator Attenuation level Enter modulator IP address Submit Attenuation level Enter attenuatio...
Страница 18: ...l or individual carriers on or off In the example shown in Figure 20 we have turned on all the carriers in the NTSC 8 Figure 20 Carrier on off 6 5 Sharpness This control is not active 6 6 Reset Entering a 1 in the reset field and clicking submit will restart the NTSC 8 Upon reset the status table will disappear Reset is complete in about 2 minutes Enter 1 to turn carrier on Check box to apply to a...
Страница 19: ...ification of Streams As shown in Figure 21 the bytesRecieved column will continually grow as the COM46 streams to the NTSC 8 The display is static so you will need to refresh the screen to see the value change Refresh the screen by clicking on the Submit button in the NTSC8 Modulator section Each time the screen refreshes you will see the bytesRecieved column change If the value is not changing th...
Страница 20: ...rom the COM46 Software upgrade page as shown below in Figure 22 Figure 22 COM46 TFTP Feature on Pairing Info Page Navigate to the NTSC tab Paste the file name into the tftpFilename field in the control section and enter the IP address of the COM46 card as shown below in Figure 23 Click submit Figure 23 NTSC 8 Software Update Upload software and copy filename Paste filename Enter IP address of COM4...
Страница 21: ...ront panel represents each modulator on the NTSC Figure 25 below defines the status of the lights displayed LED State Mode Description Solid Green Normal Normal Function Flashing Yellow Downloading During tftp file download usually for SW update LED blinks yellow 200ms on 200 ms off Flashing red green Software update Do not restart unit unit automatically restarts after SW update LED will return t...