![Technicolor COM1000 Скачать руководство пользователя страница 125](http://html.mh-extra.com/html/technicolor/com1000/com1000_integrators-manual_1068007125.webp)
125
Appendix C
Troubleshooting the COM1000
Problem/ Condition
Possible Interpretations
What to do
PWR LED continues to flash
for more than 2 minutes after
reboot
Card is still searching for guide.
Communication with card may be
unreliable until guide data is
acquired.
If the current weather conditions are
favorable, it is recommended that the
installer revisit the RF installation
guidelines.
Tuner LED is unlit /
SNR = 0 / AGC = -140
Tuner is not locked to a channel.
Card rebooted with “Persistent” field
set to „0‟.
Possible RF problems.
Possible guide acquisition problems.
Attempt to retune to the channel.
Make sure “Persistent” field is set to „1‟.
Revisit the RF installation guidelines.
SNR = 5/ AGC = -17
Inadequate RF quality level.
Signal strength is too high.
As these conditions could lead to card
instability, it is recommended that the
installer revisit the RF installation
guidelines.
Tuner LED is lit, but orange
LED on the Ethernet flashes
slowly
Card is not streaming video.
Card is attempting to send to an
unreachable IP address.
Possible authorization problem.
Verify that the destination IP and port
number values are correct.
Check the CAM log for authorization
problems. If found, tune to channel 100
and attempt reauthorization.
Tuner LED is blinking
Tuner is locked but no video packets
are being sent.
Possible authorization problem.
Check the CAM log for authorization
problems. If found, tune to channel 100
and attempt reauthorization.
All three LEDs are blinking
once a second
The RID is outside of the expected
range.
Software before 02.07.03 was loaded
on new cards with a RID that didn‟t
start with 0300.
Send card to Technicolor.
Channel = 0
Card has not fully booted yet.
An invalid Channel Object ID has
been entered.
Guide acquisition problem.
Local channel acquisition problem.
If left in this state for too long, the
card will lose authorization.
Wait for the PWR LED to stop flashing.
Reboot the card to force it to get new guide
data and then attempt to retune it.
Check the CAM log for authorization
problems. If found, tune to channel 100
and attempt reauthorization.
Содержание COM1000
Страница 1: ...REV 2 72 DIRECTV COM1000 Integrator s Manual Software Version ST02 08 07 ...
Страница 8: ...8 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 9: ...9 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 16: ...16 content compression type and it will stream either MPEG 2 or MPEG 4 encoded transport streams ...
Страница 29: ...29 Figure 10 COM24FLX to SWM Module connections ...
Страница 39: ...39 Figure 17 Tftpd32 Settings Window Global Settings ...
Страница 40: ...40 Figure 18 Tftpd32 Settings Window TFTP Settings ...
Страница 45: ...45 Figure 24 Discover Page w COM24FLX ...
Страница 62: ...62 See device labeled Exhaust Fan 2 in Figure 3 in Section 3 2 ...
Страница 88: ...88 Figure 46 COM1000 EPG Page Configured ...
Страница 102: ...102 The results of the upgrade in Figure 55 is shown in Figure 56 Figure 56 Multi card COM24 SW Upgrade Results ...
Страница 106: ...106 Figure 59 shows the results of starting a QAM24 SW upgrade Figure 59 QAM24 SW Upgrade Results ...
Страница 111: ...111 The directory path and filename do not exceed the maximum limit of 200 characters ...
Страница 129: ......