Technica Engineering 1000Base-T1 SPY mini Скачать руководство пользователя страница 1

Manual-Version: 4.0 

Hardware-Version: 1.4 and 2.0 

USER MANUAL 

July 2020 

1000BASE-T1 

MEDIACONVERTER 

EMC 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

Содержание 1000Base-T1 SPY mini

Страница 1: ...Manual Version 4 0 Hardware Version 1 4 and 2 0 USER MANUAL July 2020 1000BASE T1 MEDIACONVERTER EMC...

Страница 2: ...2 Warranty and Safety Information 6 1 3 RoHS Certificate of Compliance 8 2 HARDWARE INTERFACES 9 2 1 Connectors 9 2 1 1 MATEnet Connector 10 2 1 2 Optical Interface on the backside 11 2 1 3 SFP Interf...

Страница 3: ...aConverter EMC User Manual 3 5 4 3 Examples 19 6 1000BASE T1 Filter 27 7 GENERAL EMC TEST INFORMATION 28 8 ADDITIONAL INFORMATION 29 9 LIST OF FIGURES 30 10 CHANGELOG 31 11 CONTACT 32 12 DECLARATION O...

Страница 4: ...EMC Figure 1 1 1000BASE T1 MediaConverter_EMC The Technica Engineering 1000BASE T1 MediaConverter_EMC transmits data frames directly from the physical layer 1000BASE T1 to a chosen physical layer of t...

Страница 5: ...0BASE T1 MediaConverter EMC here https technica engineering de produkt 1000base t1 mediaconverter emc 1 1 4 General operating and safety strategy of Technica Engineering s Products Technica Engineerin...

Страница 6: ...gh supply voltage by switching the device off This automatic switch off function is independent of any software function The root cause of excessive temperature in the power supply circuit can eventua...

Страница 7: ...ngineering products must not be considered as a safety element out of context when using safety critical systems and must be included in the safety assessment when used The development class in a safe...

Страница 8: ...Converter EMC User Manual 8 Please refer to CHAPTER 12 for the EU Declaration of Conformity in accordance with Directive 2014 30 EU 1 3 RoHS Certificate of Compliance Figure 1 2 Copy of RoHS Certifica...

Страница 9: ...ual 9 2 HARDWARE INTERFACES 2 1 Connectors On the label on top of the device you can see an overview about all HW Interfaces of the 1000BASE T1 MediaConverter_EMC Figure 2 1 Label of 1000BASE T1 Media...

Страница 10: ...can use the official Tyco tool for these crimp contacts The pinning of the ECU connector is shown on the label on top of the device as well See FIGURE 2 1 The MATEnet connector is for BUS connection t...

Страница 11: ...USB Adapter is required For detailed Information see CHAPTER 0 Figure 2 3 USB Opto Adapter Plug in the optical cable on both sides crossover RX TX Open a Terminal program e g TeraTerm at your PC and...

Страница 12: ...rror Counter displayed Here is an example Figure 2 4 Example for shown values in Tera Term 2 1 3 SFP Interface There is one SFP cage for a MiniGBIC module Following SFP modules are tested and recommen...

Страница 13: ...atus LEDs The 1000BASE T1 MediaConverter_EMC has four LEDs at the frontside of the case Upper left LED No 1 Green Color It is lit when there is a linkup on the SFP Port Lower left LED No 2 Yellow Colo...

Страница 14: ...BASE T1 Port is set to Master 1000BASE T1 Port is set to Slave 2 ON up OFF down 1000BASE T1 Mode 100BASE T1 Mode 3 ON up OFF down IEEE mode A2 Legacy Mode A0 4 ON up OFF down Frame Generator Enable Fr...

Страница 15: ...y compatible with PHY Z0 Z1 and A0 versions However when connecting to 1000BASE T1 Transceivers of different vendors no linkup is possible On the other hand there is the 1000BASE T1 Media Converter HW...

Страница 16: ...e DUT in TestMode It is not a guide how to execute a Physical Layer Test 5 2 How to get the USB Opto Adapter This adapter is available from Technica engineering Please ask technical sales technica eng...

Страница 17: ...User Manual 17 5 4 Testmodes and Optical Status Information 5 4 1 First steps After the Setup following status information will be displayed Figure 5 2 Status Information Sending a capital T key to th...

Страница 18: ...eration 1 Droop 2 Transmitter Jitter and Clock Frequency Master 3 Transmitter Jitter Slave 4 Distortion 5 PSD Peak Differential Output TestModes for 1000BASE T1 0 Normal Operation 1 Setting MASTER and...

Страница 19: ...erter EMC User Manual 19 5 4 3 Examples In the following figure you can see some examples of the output during different TestModes 5 4 3 1 DUT in 100BASE T1 Mode TestMode 0 Figure 5 4 Normal Operation...

Страница 20: ...1000BASE T1 MediaConverter EMC User Manual 20 TestMode 1 Figure 5 5 TestMode 1 for 100BASE T1 Mode...

Страница 21: ...1000BASE T1 MediaConverter EMC User Manual 21 TestMode 2 Figure 5 6 TestMode 2 for 100BASE T1 Mode...

Страница 22: ...1000BASE T1 MediaConverter EMC User Manual 22 TestMode 5 Figure 5 7 TestMode 5 for 100BASE T1 Mode...

Страница 23: ...1000BASE T1 MediaConverter EMC User Manual 23 5 4 3 2 DUT in 1000BASE T1 Mode TestMode 0 Figure 5 8 Normal Operation for 1000BASE T1 Mode...

Страница 24: ...1000BASE T1 MediaConverter EMC User Manual 24 TestMode 2 Figure 5 9 TestMode 2 for 1000BASE T1 Mode...

Страница 25: ...1000BASE T1 MediaConverter EMC User Manual 25 TestMode 5 Figure 5 10 TestMode 5 for 1000BASE T1 Mode...

Страница 26: ...1000BASE T1 MediaConverter EMC User Manual 26 TestMode 6 Figure 5 11 TestMode 6 for 1000BASE T1 Mode...

Страница 27: ...diaConverter EMC User Manual 27 6 1000BASE T1 Filter The following 1000BASE T1 Filter is used in the 1000BASE T1 MediaConverter_EMC The Pulse AE5002 is used Figure 6 1 Used Filter in 1000BASE T1 Media...

Страница 28: ...ed in this setup There will be no Link Drop on 100BASE T1 or 1000BASE T1 Warning BCI closed loop method is not allowed for 100BASE T1 or 1000BASE T1 products This test would permanently damage any dev...

Страница 29: ...optimized for automotive use The maximum cable length for 1000BASE T1 segments is limited to 15 meters HW version until v1 3 was delivered with nano MQS connector instead of MATEnet connectors If you...

Страница 30: ...in Tera Term 12 Figure 5 1 Setup 16 Figure 5 2 Status Information 17 Figure 5 3 TestMode Menu 18 Figure 5 4 Normal Operation for 100BASE T1 Mode 19 Figure 5 5 TestMode 1 for 100BASE T1 Mode 20 Figure...

Страница 31: ...about USB Opto Adapter added 03 04 2019 3 2 2 1 1 Added Connector Information 29 07 2019 3 3 4 Correction chapter 27 08 2019 4 0 1 1 4 Added information on General Operating and Safety Strategy of Tec...

Страница 32: ...ing this product please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 M nchen Germany Technical support support technica engineering de General information Info technica engin...

Страница 33: ...ring GmbH et toode h ivamismoodul 1000BASE T1 MediaConverter EMC TE 1400 1 vastab direktiivi 2014 30 EL nuetele ELi vastavusdeklaratsiooni tielik tekst on kttesaadav jrgmisel internetiaadressil https...

Страница 34: ...ica engineering de produkt 1000base t1 mediaconverter emc Malti B dan Technica Engineering GmbH niddikjara li l prodott 1000BASE T1 MediaConverter EMC TE 1400 1 huwa konformi madDirettiva 2014 30 UE I...

Страница 35: ...o skladnosti je na voljo na naslednjem spletnem naslovu https technica engineering de produkt 1000base t1 mediaconverter emc Slovensky Technica Engineering GmbH t mto vyhlasuje e produkt 1000BASE T1...

Отзывы: