7 - STARTING

Before carrying out any work on the installation, make sure that it is switched off and that access to it is prevented.

Any work must be carried out by personnel qualified and authorised to work on this type of machine.

IMPORTANT NOTE

6.4 - RS 485 COMMUNICATION INTERFACE (MODBUS

protocol)

• Code 

70250056

.

• After removing the side panel, also remove the front panel 

A

(remove the

three retaining screws 

B

and pull the panel downwards).

• Secure the communication interface 

C

on the left-hand side of the electric

panel.

• Connect the cable (supplied) between the communication interface 

C

and

the controller 

D

.

• Connect the module's 230 VAC power supply in the following manner with

the black and blue wires delivered with the accessory.

• Connection of the communication bus and protocol detail:

refer to the corresponding technical file.

34

1

N2

U2

9

8

B
U
S ADAPTER

2

B

A

B

B

C

D

E

Filter

interface

Blue (N2)

Black (U2)

Existing wires to
disconnect from the
filter and to connect to
the wires of the
accessory

Blue (N2)

Black (U2)

Wiring board

7.1 - CHECK

• That hydraulic connections are properly tight and that the hydraulic circuit functions correctly:

- purge of circuits,
- position of valves,
- hydraulic pressure (2 bar).

• That there are no leaks.
• That the machine is stable.
• That the power cables are well fixed to their connection terminals. Terminals that are poorly tightened may cause

overheating and malfunctions.

• That the electric cables are well insulated from any sections of sheet metal or metal parts which could damage them.
• That probe, control and power cables are properly separated.
• That the machine is earthed.
• That there are neither tools nor other foreign objects in the units.

7.2 - WATER QUALITY

• In order for the heat pump to operate under good conditions and provide optimum performance, it is essential to ensure that

the system’s water circuit is clean. If the water circuit becomes clogged, this will significantly affect the machine’s
performance. The circuit must therefore be cleaned with suitable products in compliance with current standards as soon as
it is installed, both for new and renovation work.
We recommend the use of products which are compatible with all metals and synthetic materials and approved by official
bodies.
Recommendations regarding water quality:

- PH: 6 to 9
- TH: 10 to 20°F
- Dry material in suspension: < 2 g/l
- Granulometry: < 0.4 mm

- Chloride: 50 mg/l maximum
- Conductivity: 50 to 500 µS/cm

2

- Resistivity: 1 to 10 k

- Fibre: no fibres

Any disorder which may occur on our machines due to the poor quality of the fluid in the installation will not be covered by
the TECHNIBEL warranty.

 

Содержание PHTJ 14/19

Страница 1: ...aldamento Fluido refrigerante R 407 C Bomba de calor de alta temperatura con equipamiento hidr ulico s lo calefacci n Fluido refrigerante R 407 C Hochtemperatur W rmepumpe mit Hydraulikmodul Nur Heize...

Страница 2: ...18 R 407 C Fluid R 407 C is not a pure fluid but a blend composed of 23 R 32 25 R 125 52 R 134 A The compressors approved for operation with this fluid are filled beforehand with polyalcohol oil Contr...

Страница 3: ...on the installation check that its power supply is disconnected and locked out 1 4 USE OF EQUIPMENT This device is designed for heating buildings This appliance is not designed to be used by people i...

Страница 4: ...t not be directed towards surrounding windows vibrations and noise must not be transmitted to a nearby building avoid exposure to salty air or sulphuric gas the proximity of the extractor fan projecti...

Страница 5: ...devices not supplied See ratings in the table below Note The unit is designed to be connected to a power supply having a TT neutral regime neutral to ground or TN S regime to neutral as per NF C 15 10...

Страница 6: ...is light flashes if a safety delay is in progress It stays on when the compressor is operating The control probe SD1 is located on the water inlet in the factory The controller is connected on a print...

Страница 7: ...paragraph 5 4 If the light flashes it means that the compressor is starting required but that a safety delay is in progress This light stays on when the compressor has started To stop the unit open t...

Страница 8: ...s 1 and above are accessed Note 2 The normal display level 0 returns automatically after 5 minutes if no buttons are pressed Level 0 Normal display Level 1 Level 2 Level 3 Level 4 Temperature S1 Alarm...

Страница 9: ...ection in the menu Briefly and simultaneously press buttons 1 and 2 The message appears Enter the password using buttons 1 and 2 and validate it by simultaneously pressing buttons 1 and 2 It is now po...

Страница 10: ...ilation can restart after defrosting is completed to prevent excessive pressure build up For special climatic conditions the factory set time counter value of 30 minutes can be adjusted To do this mod...

Страница 11: ...or lamp flashes The stand by mode is indicated by the extinction of the heating mode indicator lamps Pre ventilation Generally speaking in order to condition the air heat exchanger the fan always star...

Страница 12: ...55 The functions and display are exactly the same as those on controller The only difference concerns the buttons and which are separated by the ON OFF and Mode buttons Reminder the parameters are acc...

Страница 13: ...ssure 2 bar That there are no leaks That the machine is stable That the power cables are well fixed to their connection terminals Terminals that are poorly tightened may cause overheating and malfunct...

Страница 14: ...e cleaning and protection of condensate tanks Treating odours and the disinfection of room surfaces and volumes also contributes to the cleanliness of the air breathed by users Carry out the following...

Страница 15: ...er use oxygen or dry air as the risk of fire or explosion is present Use dehydrated nitrogen or a nitrogen and refrigerant mix indicated on the manufacturer s plate For units equipped with pressure ga...

Страница 16: ...3 00 27 89 13 4 43 4 61 4 93 18 99 22 94 27 87 14 4 50 4 68 5 06 18 95 22 89 27 85 15 4 57 4 76 5 19 18 92 22 83 27 83 16 4 64 4 84 5 32 18 88 22 77 27 82 17 4 71 4 92 5 45 18 84 22 72 27 80 18 4 79 5...

Страница 17: ...11 4 43 18 99 22 64 25 60 14 4 12 4 18 4 56 18 95 22 59 25 58 15 4 19 4 26 4 69 18 92 22 53 25 56 16 4 26 4 34 4 82 18 88 22 47 25 55 17 4 33 4 42 4 95 18 84 22 42 25 53 18 4 41 4 50 5 08 18 80 22 36...

Страница 18: ...ink N Black R Red W White Colours of the wires M3 1 U N 45 1 3 2 4 KM3 M2 1 S R C M N B L1 L3 L1 B B 46 N C1 32 31 P3 56 55 J1 E2 BP 54 53 L L BP G R1 HP G HP 52 51 A1 SD 4 SD 3 SD 2 SD 1 U2 U1 N1 N2...

Страница 19: ...2 R1 W3 26 25 24 23 KM2 W2 W1 21 22 22 21 7 5 6 4 2 3 1 P1 P2 N XP PE XP U XP M M1 1 P W G M G 2 1 5 4 3 CX1 M11 1 P W G M G 2 1 5 4 3 CX2 C11 M B E1 U1 N1 N B U SD1 SD2 SD3 P4 P5 CN1 I CN1 II A3 SD4...

Страница 20: ...F GB D P I E...

Страница 21: ...F GB D P I E...

Страница 22: ...dificarli senza preaviso En el inter s de mejoras constantes nuestros productos pueden modificarse sin aviso pr vio Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert...

Отзывы: