background image

Made in  

FRANCE

Référence 10.11.560 GB.02

User manual

The information within this document is not contractual, we reserve the right to modify without warning the technical characteristics and the equipment of all appliances. 

LIBERTY300

 Domestic hot water heat pump

Содержание Liberty300 Solar

Страница 1: ... 560 GB 02 User manual The information within this document is not contractual we reserve the right to modify without warning the technical characteristics and the equipment of all appliances LIBERTY300 Domestic hot water heat pump ...

Страница 2: ...ly activated Taking into account the domestic hot water consumption and in the aim of savings it is advised to set the water temperature at 50 C for example 1 Control display Signification of symbols Compressor activated Ventilation activated Defrosting Electrical backup activated Need for domestic hot water Econo mode activated by time programming or external activation Vacation mode activated Me...

Страница 3: ...t the end hour of period 1 0000 0630 H G set confort mode COMF or Standby mode HG for period 1 0630 ____ 22 00h set the end hour of period 2 0630 2200 COMF set confort mode COMF or Standby mode HG for period 2 repeat up to 7 periods per day COPY SUN copy of program the day before COPY PROG copy of program MODIF PRG modification of program SEE PROG to see a program Time for heating up of the tank d...

Страница 4: ...5 1 5 2 5 3 Direct access by pressing the Menu button Direct access by pressing Clock settings 4 Time setting 26 09 12 17 32 09 12 17 32 Day setting 26 12 17 32 Month setting 26 09 17 32 year setting MONDAY 32 hour setting MONDAY 17 Min setting 4 USER MANUEL DOMESTIC HOT WATER HEAT PUMP ...

Страница 5: ... dial to scroll through the menu choices 5 2 Standby mode during vacation period VACATIONS RETURN 8 number of day in standby mode Press the Menu button to return to the main screen The VACATIONS function ends automatically at the same time as soon as the number of days have passed During the entire duration of the vacation D W H P will display RETURN Return from vacation along with a countdown for...

Страница 6: ...NO Select YES 500 C enter example LOCKING LOCKING NO Select level of locking Unlocking press the button for 3 sec Nota When locking is actived only access to unlocking and alarm reset is possible Press 3 sec enter UNLOCKING NO UNLOCKING YES 500 C Press 3 sec Press 3 sec pro To access to menu is locked Temporary 300 sec unlocking is performed by pression 3 sec on button and 3 sec on simultaneously ...

Страница 7: ...WHU VHQVRU RXW RI WKH WDQN 9HULI WKDW WKH WDQN LV IXOO RI ZDWHU DQG DLU SULPHG 9HULI WKH ZDWHU WHPSHUDWXUH VHQVRU SRVLWLRQ LQ WKH WDQN 5HSODFH WKH VHQVRU Heat pump stopped Electrical heater heats water to 43 C min 38 C Back up operation authorized 1 0 1 HIURVWLQJ WRR IUHTXHQWO DFN RI DLU IORZ LU LQOHW RU RXWOHW EORFNHG XFW LV WRR ORQJ RI KDV WRR PDQ HOERZV YDSRUDWRU GLUW 6HW WKH YHQWLODWRU WR PD V...

Страница 8: ...B1871860 12 185 Zone Industriel RD28 BP131 Reyrieux 01601 TREVOUX Tél 33 04 74 00 92 92 Fax 33 04 74 00 42 00 http www technibel com ...