background image

EG

I

F

D

E

37.4254.076.00    11/2015

Split air conditioner system • Condizionatore d’aria split system

Climatiseurs split • Split-klimagerät

Acondicionador de aire de consola partida sistema split

KPA8FIA0R5IBA
KPA9FIB0R5IBA

NOTICE D’UTILISATION • OPERATING INSTRUCTIONS

ISTRUZIONI D’USO • INSTRUCCIONES DE USO

BEDIENUNGSANLEITUNG

Содержание KPA8FIA0R5IBA

Страница 1: ...em Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split KPA8FIA0R5IBA KPA9FIB0R5IBA NOTICE D UTILISATION OPERATING INSTRUCTION...

Страница 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Страница 3: ...ect the power Use the main power switch to turn off power completely WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 7 8 9 5 3 4 2 1 6 OFF LAMPS FUNTION It is possible to set the air conditione...

Страница 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Страница 5: ...n to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically s e l e c t e d b y t h e microcom...

Страница 6: ...to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automatically adjusted not only according to the air temperature but a...

Страница 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Страница 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Страница 9: ...air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP button on the remote control to adjust the position of the flap If you move the flap...

Страница 10: ...low the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT TH...

Страница 11: ...t 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking sound is heard from the air conditioner...

Страница 12: ...p is closed The system restarts automatically as soon as a correct operating mode is selected Set the outdoor indoor unit refrigerant circuit address see Installation Instructions Select an available...

Страница 13: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Страница 14: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Страница 15: ...ler providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Страница 16: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Отзывы: