GR9FI50R5IAB

 

Cooling Characteristics

 

Heating Characteristics

1

0.8180.531.00     05/2007

Note

Overload prevention operates to protect the air conditioner when outdoor ambient temperature reaches
extremely high values in heating mode.

Points of Rating condition

Data referred to  

MTAF(B)IA0R5I x2

0,50

0,60

0,70

0,80

0,90

1,00

1,10

1,20

1,30

1,40

1,50

10

15

20

25

30

35

40

Outdoor inlet air D.B. temperature (°C)

Low pres

su

re at

 wi

de t

ube s

erv

ic

e v

al

ve M

P

a

1,5

1,7

1,9

2,1

2,3

2,5

2,7

2,9

0

5

10

15

20

Outdoor inlet air D.B. temperature (°C)

Hi

gh pres

su

re at

 wi

de t

ube s

erv

ic

e v

al

ve M

pa 

0,0

1,0

2,0

3,0

4,0

5,0

6,0

7,0

10

15

20

25

30

35

40

Outdoor inlet air 

D.B.

 temperature (°C)

Operat

ing c

urrent

 (A

)

Indoor inlet air

D.B. (°C)

32

27

19

2,0

3,0

4,0

5,0

6,0

7,0

8,0

0

5

10

15

20

Outdoor inlet D.B. temperature (°C)

Operat

ing c

urrent

 (A

)

Indoor inlet air

D.B. (°C)

25

20

15

Indoor inlet air

D.B. (°C)

Indoor inlet air

D.B. (°C)

25

20

15

32

27

19

7

7

32

27

19

12

Содержание GR9FI42R5IAA

Страница 1: ...ICE MANUAL OUTDOOR UNIT GR9FI50R5IAA GR9FI50R5IAB GR9FI42R5IAA DUAL SPLIT SYSTEM AIR CONDITIONER 0 8180 597 03 09 2012 Model No Product Code No GR9FI50R5IAA 38 7107 098 GR9FI50R5IAB 38 7107 103 GR9FI4...

Страница 2: ...t allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of...

Страница 3: ...W DIAGRAM 9 4 1 Dual Split System Refrigerant Flow Diagram 9 4 2 Mono Split System Refrigerant Flow Diagram 10 5 PERFORMANCE DATA 11 5 1 Performance Charts 11 12 13 6 ELECTRICAL DATA 14 6 1 Electrical...

Страница 4: ...GR9FI50R5IAB Heating Maximum 27 C D B Temperature Indoor Air Intake Temp GR9FI42R5IAA 24 C D B 18 C W B Minimum 5 C D B 15 C D B Outdoor Air Intake Temp Cooling Maximum 32 C D B 23 C W B 43 C D B Mini...

Страница 5: ...ANGE WITHOUT NOTICE Remarks Rating Conditions are Cooling Indoor Air Temperature 27 C D B 19 C W B Outdoor Air Temperature 35 C D B 24 C W B Heating Indoor Air Temperature 20 C D B Outdoor Air Tempera...

Страница 6: ...ose C Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT TO CHANGE WITHOUT NOTICE CHANGE WITHOUT NOTICE 1 5 0 47 2 Propeller 1 400 BOM ZW465B57 8 variable 200 800 Micropro...

Страница 7: ...mistor narrow tube B sensor Resistance k Crank case heater Resistance at 20 C Base heater Resistance at 20 C DATA SUBJECT TO CHANGE WITHOUT NOTICE CHANGE WITHOUT NOTICE 10 at 25 C NTC THERMISTOR 10 at...

Страница 8: ...3 DIMENSIONAL DATA GR9FI50R5IAA GR9FI50R5IAB GR9FI42R5IAA dimension mm WIDE TUBE 2x 9 52 3 8 NARROW TUBE 2x 6 35 1 4 4 12 for anchor bolt 8...

Страница 9: ...e is used in the outdoor unit both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated w...

Страница 10: ...both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated with a proper insulation mater...

Страница 11: ...0 1 50 10 15 20 25 30 35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressu...

Страница 12: ...35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressure at wide tube servi...

Страница 13: ...35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressure at wide tube servi...

Страница 14: ...Outdoor Air Temperature 7 C D B 6 C W B NOTE Data referred to 2 indoor unit MTAF B IA0R5I x2 For other indoor unit models there could be some differences GR9FI42R5IAA COOLING 2 Indoor Unit Fan Motor...

Страница 15: ...6 2 Electric Wiring Diagram Outdoor unit GR9FI50R5IAA PRODUCED BEFORE DEC 31 2010 Outdoor unit GR9FI50R5IAA PRODUCED AFTER GEN 1 2011 GR9FI50R5IAB GR9FI42R5IAA 15...

Страница 16: ...Outdoor unit GR9FI50R5IAA PRODUCED AFTER GEN 1 2011 GR9FI50R5IAB GR9FI42R5IAA Indoor unit MTAF B IA0R5I x2 6 4 Mono Split System Wiring Diagram Outdoor unit GR9FI50R5IAA PRODUCED BEFORE DEC 31 2010 I...

Страница 17: ...C NOTES The troubles are showed according to a priority list that is in case of more than one trouble present is always showed at first the one with the highest priority 3 2 1 etc Sensor damaged mean...

Страница 18: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Отзывы: