4. COOLING CAPACITY
9
Indoor Unit MCA27RM (
×
1)
Outdoor Unit GR54M2R
230 V Single phase 50 Hz
RATING CAPACITY 2.60 kW
AIR FLOW RATE 470 m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 20 25 30 35 40 45
TC 2.62 2.51 2.39 2.28 2.14 1.97
CM 0.68 0.74 0.79 0.85 0.95 1.06
21 SHC 1.81 1.76 1.70 1.64 1.58 1.50
15 23 SHC 2.04 1.99 1.93 1.88 1.81 1.73
25 SHC 2.28 2.22 2.16 2.11 2.04 1.96
27 SHC 2.51 2.45 2.39 2.28 2.14 1.97
29 SHC 2.62 2.51 2.39 2.28 2.14 1.97
31 SHC 2.62 2.51 2.39 2.28 2.14 1.97
TC 2.81 2.69 2.57 2.44 2.30 2.11
CM 0.70 0.76 0.81 0.87 0.97 1.08
21 SHC 1.57 1.52 1.46 1.40 1.34 1.26
17 23 SHC 1.81 1.75 1.69 1.64 1.57 1.49
25 SHC 2.04 1.98 1.93 1.87 1.80 1.72
27 SHC 2.27 2.21 2.16 2.10 2.04 1.96
29 SHC 2.50 2.45 2.39 2.34 2.27 2.11
31 SHC 2.74 2.68 2.57 2.44 2.30 2.11
TC 2.99 2.86 2.73 # 2.60 2.44 2.25
CM 0.72 0.78 0.84 0.90 1.00 1.11
21 SHC 1.32 1.27 1.21 1.16 1.09 1.01
19 23 SHC 1.56 1.50 1.44 1.39 1.32 1.24
25 SHC 1.79 1.73 1.68 1.62 1.56 1.48
27 SHC 2.02 1.96 1.91 1.85 1.79 1.71
29 SHC 2.25 2.20 2.14 2.09 2.02 1.94
31 SHC 2.49 2.43 2.37 2.32 2.25 2.17
TC 3.17 3.03 2.89 2.76 2.59 2.38
CM 0.74 0.80 0.86 0.92 1.03 1.14
23 SHC 1.30 1.25 1.19 1.14 1.07 1.00
21 25 SHC 1.54 1.48 1.42 1.37 1.31 1.23
27 SHC 1.77 1.71 1.66 1.60 1.54 1.46
29 SHC 2.00 1.94 1.89 1.84 1.77 1.69
31 SHC 2.23 2.18 2.12 2.07 2.00 1.93
TC 3.36 3.22 3.07 2.89 2.71 2.52
CM 0.76 0.82 0.88 0.95 1.06 1.17
23 25 SHC 1.27 1.21 1.16 1.10 1.03 0.97
27 SHC 1.50 1.45 1.39 1.33 1.26 1.20
29 SHC 1.73 1.68 1.62 1.56 1.50 1.43
31 SHC 1.97 1.91 1.86 1.79 1.73 1.66
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
Содержание GR54M2R
Страница 11: ...3 DIMENSIONAL DATA Indoor Unit 7 MCA27RM...
Страница 19: ...8 2 Electric Wiring Diagram 15 Indoor Unit MCA27RM...
Страница 20: ...16 Outdoor Unit GR54M2R...