34
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit MCAV180R5VAA
Outdoor Unit GR180R5TAA
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.38
0.50
8.92
9.8
Power Input
kW
0.072
0.093
1.935
2.10
Full Load Conditions Running Amps.
A
0.38
0.50
11.12
12.0
Power Input
kW
0.072
0.093
2.385
2.55
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 46°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.38
0.50
9.42
10.3
Power Input
kW
0.072
0.093
1.985
2.15
Full Load Conditions Running Amps.
A
0.38
0.50
11.82
12.7
Power Input
kW
0.072
0.093
2.565
2.73
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.
Содержание GR180R5TAA
Страница 23: ...4 REFRIGERANT FLOW DIAGRAM Indoor Unit MCAV180R5VAA KPAV180R5VAA Outdoor Unit GR180R5TAA 19...
Страница 44: ...Outdoor Unit GR220R5TAA 40...
Страница 45: ...Outdoor unit GR180R5TAA 41...