Technibel AOV 15 S Скачать руководство пользователя страница 6

6

• If the air conditioner is not working properly, carry out the following checks before calling the After-Sales Department.

• If the problem persists, contact the dealer or the After-Sales Department.

9 - TROUBLESHOOTING GUIDE

PROBLEMS

• The air conditioner is not

operating at all (the fan never
comes on).

• Insufficient cooling or heating.

• The compressor does not start.

POSSIBLE CAUSES

1

- Power cut.

2

- Circuit-breaker thrown or fuse

blown.

3

- Line voltage too low.

4

- The switch is on "0" (off).

1

- Air filter dirty or blocked.

2

- Heat source or too many people in

the room.

3

- Doors and/or windows open

4

- Obstacle in front of the air inlet or

outlet.

5

- The thermostat is set too high for

cooling or too low for heating.

- The HP pressure switch has cutoff.

SOLUTIONS

1

- Restore the supply.

2

- Contact the After-Sales

Department.

3

- Consult your electrician

4

- Set switch at desired position.

1

- Clean the air filter.

2

- If possible, eliminate the heat

source.

3

- Close them to prevent outside air

entering.

4

- Remove the obstacle in order to

provide good air circulation.

5

- Set the temperature lower (or

higher).

- Check the water circulation, then

reset the pressure switch (see
above).

• Should a too high pressure occur in the refrigerant circuit, the compressor is switched off (22 bar).

The high pressure switch has to be manualy reset. To do so, remove the plastic cap on the top of the unit and press the switch
by means  of a screw driver or a pen.

10 - PRESSOSTAT RESETING

Содержание AOV 15 S

Страница 1: ...1 OPERATING INSTRUCTIONS 10 11 184 GB 04 July 2005 AOV AOV 15 S AOV 25 S AOV 55 SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER...

Страница 2: ...s ou appareils lectriques et lectroniques contiennent fr quemment des mati res qui si elles sont trait es ou li min es de mani re inappropri e peuvent s av rer potentiellement dangereuses pour la sant...

Страница 3: ...e babies or sick people in it 4 SAFETY INSTRUCTIONS 3 ELECTRICAL PRECAUTIONS Before installing make sure that the mains voltage is the same as the voltage indicated on the air conditioner s rating pla...

Страница 4: ...s and to the red area for higher temperatures NOTE When the required temperature is reached only the ventilation continues to operate 0 1 2 3 4 5 7 6 8 SWITCH THERMOSTAT 6 MAINTENANCE AND CLEANING IMP...

Страница 5: ...are closed in order to prevent non cooled air entering when the appliance is operating in the cooling mode A FILTER If the air conditioner is to operate satisfactorily the air filter must be cleaned r...

Страница 6: ...inlet or outlet 5 The thermostat is set too high for cooling or too low for heating The HP pressure switch has cutoff SOLUTIONS 1 Restore the supply 2 Contact the After Sales Department 3 Consult your...

Страница 7: ...licy of continuous development our products are liable to modification without notice R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France Tel 33 4 74 00 92 92 Fax 33 4 74 00 42 00 R C S Bourg en Bresse...

Отзывы: