background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

In

 

IL-TRACKER575W/1 

formation specifically for:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1.2 

This manual contains important information.

Please read before operating fixture.

Содержание IL-TRACKER575W/1

Страница 1: ...In IL TRACKER575W 1 formation specifically for V1 2 This manual contains important information Please read before operating fixture...

Страница 2: ...2005 Techni Lux Inc 2...

Страница 3: ...purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obt...

Страница 4: ...tor 12 Adapter 5 to 3 pin 12 Control Panel Menu 13 Start Address 13 Example 13 DMX 512 Channels 14 CH 1 4 Pan Tilt Movement 14 CH 5 Movement Speed Pan Tilt 14 CH 6 Control Reset Lamp 15 CH 7 Fixed Col...

Страница 5: ...le shutter for strobe effects and quick blackouts Motorized dimmer from 0 to 100 Control via DMX512 using 3 pin In Out XLRs Uses 16 Channels of DMX Digital display for DMX addressing and fixture setti...

Страница 6: ...er 850W 7A 120v Fuses 15A Time Delay Slow Size x 1 Control Protocol USITT DMX512 1990 Channels 16 Pan Tilt Resolution16 bit Data I O 3 Pin XLR Cannon Modes Master Slave DMX Optics Reflector High effic...

Страница 7: ...ts Front panel 10 Mode button 11 Enter button 12 Up button 13 Down button 14 Display Rear panel 5 Power switch 6 DMX output 7 DMX input 8 Power cord 9 Fuse holder 1 Moving head 2 Yoke 3 Carry handles...

Страница 8: ...plied to return items not received in original or incomplete packing Claims Physical damage must be reported to the Freight Carrier or Shipping Company upon receipt of merchandise Damage incurred in s...

Страница 9: ...tches the power source voltage Consult a qualified electrician if there are any concerns about proper connection to power Pin Cable EU International Brown Light blue ellow Green Y Black White Green Li...

Страница 10: ...e maximum possible life As Discharge lamps age the glass envelope becomes weaker increasing the chance of failure due to the high internal pressures Rupture could result in damage to the fixture and o...

Страница 11: ...the projected beam is as evenly bright as possible 3 adjustment screws A B C Mounting Always consult a qualified professional when rigging This fixture may be placed on any flat surface or truss that...

Страница 12: ...installations To make a Data Terminator connect a 120 ohm watt resistor across pin 2 Data Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adap...

Страница 13: ...tart Address of eleven 11 would read data from channels 11 and 12 13 14 15 The next logical Start Address would be channel 16 Because all fixtures see the same data fixtures may be set to any address...

Страница 14: ...ct automatically The Pan and Tilt Menu Modes can be used to alter the default direction of movement Movement speed is either automatically determined by the fixture or manually set using Channel 5 Pan...

Страница 15: ...27 No Function 128 139 RESET then Lamp ON 3 second delay 140 229 No Function 230 239 Lamp OFF 3 second delay 240 255 No Function CH 7 Fixed Color Wheel The Fixed Color Wheel holds 4 solid colors 2 col...

Страница 16: ...ther CMY channels and the Fixed Color Wheel to create many color combinations CH 9 Magenta Mix DMX Value Function 0 255 Magenta Saturation Least to Most CH 10 Yellow Mix Controls the saturation of the...

Страница 17: ...7 Color Preset 11 168 181 Color Preset 12 182 195 Color Preset 13 196 209 Color Preset 14 210 223 Color Preset 15 224 237 Color Preset 16 238 251 Color Preset 17 252 255 Color Preset 18 CH 13 Effects...

Страница 18: ...the shutter at irregular intervals CH 15 Shutter DMX Value Function 0 31 Closed Black Out 32 63 Open 64 95 Strobe Effect Slow to Fast 96 127 Open 128 131 Pause 132 159 Pulse Strobe Effect Slow to Fast...

Страница 19: ...Photometric Charts 19...

Страница 20: ...andled by the controller The physical signals are transmitted using a twisted pair of wires and a common shield a configuration called Balanced The controller and all receiving equipment are connected...

Страница 21: ...nics mechanical elements reduce lamp life fixture life and over all performance Before conducting any maintenance disconnect fixture from power mains 1 Disconnect fixture from power mains 2 Use a vacu...

Страница 22: ...ts then function correctly issue is programming Bad or end of life lamp Check DMX value for Control Reset Lamp Channel Inspect fixture light path and verify no effects are blocking beam Remove from DM...

Страница 23: ...Fan TILT ENCODER SENSOR PAN SENSOR TILT SENSOR DIMMER STROBE SPIRAL LENS 1 SPIRAL LENS 2 RIPPLE LENS 2106L SPIRAL LENS ZOOM SENSOR RIPPLE LENS SENSOR IGNITER BALLLEST TEMPERATURE SWITCH POWER SUPPLY F...

Страница 24: ...18 SAFETYCABLE4 Safety Cable Silver 18 CA XLR3 1 Pre made 1 3 pin XLR Cable CA XLR3 5 Pre made 5 3 pin XLR Cable CA XLR3 10 Pre made 10 3 pin XLR Cable CA XLR3 20 Pre made 20 3 pin XLR Cable CA XLR3...

Отзывы: