background image

 

15 

Troubleshooting 

Symptom 

Possible Cause / Solution 

No Power 

Check for power on mains 
Check main fuse and fuse holder 

Erratic / No response to DMX 

Check data cables: connection and proper wiring  
Check Display settings 
Check Start Address 

Incorrectly responds to DMX 

(Diagnostic technique for DMX issues: Set 

suspect fixture’s Start Address the same as a 

correctly functioning fixture. If both units then 

function correctly, issue is programming) 

Check Start Address 
Check for overlapping addresses 
Check Menu and Mode settings 
Check Data cables (faults and proper wiring) 

 

 

 

 

 

 

DMX-512 Background 

DMX-512 is a digital data transmission standard developed by the United States Institute for Theater Technology 

(USITT).  It is designed to enable control of lighting equipment.  DMX deals solely with the formatting of data for 

transmission and does not dictate how the data is created or used. 

 

Under DMX, signals are transmitted in much the same way a computer modem transmits data.  The Data, divided 

into channels, is "Framed" using a start bit, high (1), eight data bits and finally, two stop bits, both high (1). DMX 

uses no parity to check the integrity of the signal.  Instead, DMX relies on the ultra low probability of an error 

occurring in the same place when the data is resent.  The rate at which data is sent is fixed at 250k bps, almost four 

and a half times faster that a 56k modem.   This speed allows all data on a DMX chain to be updated more than 44 

times every second. 

 

The transmitted data follows a specific format. DMX allows for 512 channels each with eight data bits, giving each 

channel the possibility of 256 values.  When a data "Packet" is sent, all channels are transmitted one after another.  

Even if the data on a specific channel has not been changed, it must be sent.  In a packet, a "start code" of all zeros 

is sent before the data to identify the signal as a Standard DMX transmission.  This start code is transparent to the 

user and is handled by the controller. 

 

The physical signals are transmitted using a twisted pair of wires and a common shield, a configuration called 

Balanced.  The controller and all receiving equipment are connected using a “Daisy Chain" connection.  The signal 

is jumped from the controller to a piece of DMX equipment.  From there, the signal is jumped to the next piece of 

equipment and so on until the last piece of equipment is connected.  No branches are allowed and the signal does 

not come back to the controller.  The final piece of equipment will have only one cable connection.  As a result, all 

equipment connected to the  chain will see exactly the same signal whether it is first or last.  When connecting 

equipment, no particular attention needs to be paid to the order in which the equipment is connected.  Depending on 

the conditions and equipment, a line terminator may be required.  If there is any question, in most circumstances the 

addition of a terminator will not degrade the signal.  To make a terminator, attach a 120-ohm resistor between the 

Signal Data Negative and Signal Data Positive pins of a connector in the last piece of equipment in the chain. 

 

The DMX Standard uses 5 pin XLR connectors.  However, it is common to see 

fixtures with 3 pin XLR connectors as these types of balanced or “Lo-Z” cables 

are common in the audio industry.  In either case, pin numbers are the same and 

carry the same signals.  

 

Pin 

Connection 

Common (Shield) 

Data Negative (S- or Cold) 

Data Positive (S+ or Hot) 

n/c (not used) 

n/c (not used) 

Содержание DL-BAR10UV365

Страница 1: ...fically for DL BAR10UV365 Black with UV LEDS V1 0 This manual contains important information Please read before operating fixture WARNING C HIGH INTENSITY 365nm UV LIGHT DO NOT LOOK DIRECTLY INTO SOUR...

Страница 2: ...ted to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the deale...

Страница 3: ...ic Setup Wiring Diagrams 7 Operating Setting Buttons 7 Fixture Menu LED Display 8 DMX 512 Control 9 DMX Data Connection 9 Data Terminator 9 Adapters for 3 or 5 pin XLR 10 DMX Start Address 10 DMX Chan...

Страница 4: ...inum Environmental Location Indoor IP20 Min Max Ambient Temperature 13 to 105 F 25 to 40 C Min distance to flammable surface 3 3 ft 1 0 m Min distance to illuminated surface 1 0 ft 0 3 m Electrical Vo...

Страница 5: ...th a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA pri...

Страница 6: ...ician if there are any concerns about proper connection to power Mounting Always consult a qualified professional when rigging Consider access for routine maintenance when selecting a mounting positio...

Страница 7: ...ring is explained in more detail in the DMX Data Connection section of this manual Example Block Diagram Operating Setting Buttons The following refers to the settings that are available on this fixtu...

Страница 8: ...Value on Lost DMX Signal auto AUTO Program on Lost DMX Signal soun SOUND Activated on Lost DMX Signal Sped SP00 SP99 AUTO Program Speed 0 thu 99 Sens S000 S099 SOUND Sensitivity 0 thru 99 Ucol Dinn DI...

Страница 9: ...fixtures will be slaved together and respond to the same data Because all fixtures see the same data fixtures may be set to any address without concern for the order they are connected by the DMX cab...

Страница 10: ...le Select Start Addresses for 4 fixtures each requiring 10 channels of DMX For this example start with the first unit set to the first possible Start Address 1 This fixture occupies DMX channels 1 thr...

Страница 11: ...ble Strobe Slow To Fast 091 105 Strobe open 106 165 Strobe slow fast 166 180 Strobe close 181 240 Random Strobe Slow To Fast 241 255 Strobe open 3 CHANNEL MODE Channel Function Values 1 Dimmer 000 255...

Страница 12: ...3 LED 13 000 255 LED 13 0 100 14 LED 14 000 255 LED 14 0 100 15 LED 15 000 255 LED 15 0 100 16 LED 16 000 255 LED 16 0 100 17 LED 17 000 255 LED 17 0 100 18 LED 18 000 255 LED 18 0 100 22 CHANNEL MODE...

Страница 13: ...ED 3 000 255 LED 3 0 100 8 LED 4 000 255 LED 4 0 100 9 LED 5 000 255 LED 5 0 100 10 LED 6 000 255 LED 6 0 100 11 LED 7 000 255 LED 7 0 100 12 LED 8 000 255 LED 8 0 100 13 LED 9 000 255 LED 9 0 100 14...

Страница 14: ...when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separat...

Страница 15: ...acket is sent all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data t...

Страница 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Отзывы: