background image

 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information specifically for:

 

 

 

DL-BAR10C5MM 

v1.0 

This manual contains important information.

Please read before operating fixture.

Содержание DL-BAR10C5MM

Страница 1: ...Information specifically for DL BAR10C5MM v1 0 This manual contains important information Please read before operating fixture...

Страница 2: ...2 Copyright 2010 Techni Lux Inc...

Страница 3: ...to and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer o...

Страница 4: ...ic Color Operation 9 Slave Operation 9 Sound Active Operation 9 Software Version 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 11 Adapter 5 to 3 pin 11 DMX Start Address 11 DMX Channel O...

Страница 5: ...r Black Size 41 5 x 2 55 x 3 5 Weight 4 62 lbs 2 1 kgs Environmental Location Indoor Max ambient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1...

Страница 6: ...th a Return Merchandise Authorization number RMA clearly listed on the shipping label Items sent by Freight Collect or without a RMA number will be refused Call your sales person and request a RMA pri...

Страница 7: ...osed to constant water or rain high humidity extreme temperature changes or restricted ventilation Do not obstruct any vents or heat sinking Basic Reference Male 3 pin XLR Female 3 pin XLR Mounting Br...

Страница 8: ...8 Control Panel Menu Navigation...

Страница 9: ...o create your own color If you selected AtF then you must hit enter again and set the intensity of the RGB values RGB color intensity values are between 0 off to 255 100 maximum By varying the intensi...

Страница 10: ...Background Before addressing fixtures consult the manual of the system s DMX controller to select a desirable addressing scheme Valid Start Addresses range from 1 to 512 Fixtures requiring more than o...

Страница 11: ...ss that does not overlap with any other units allows you to individually control that fixture s features fully Never allow channels to overlap You will need to select the number of channels you wish t...

Страница 12: ...2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 Ch 1 2 3 5 channels Bar completely operates as 1 complete section with 2 additional control channels Ch 3 4 5 Ch 3 4 5 Ch 3 4 5 Ch 3 4 5 Ch 3 4 5 Ch 3 4 5 Ch 3 4 5 Ch 3...

Страница 13: ...annel mode 14 channel mode 24 channel mode 26 channel mode Functions 1 3 3 3 1 3 Red 2 4 4 4 2 4 Green 3 5 5 5 3 5 Blue 6 6 4 6 Red 7 7 5 7 Green 8 8 6 8 Blue 9 7 9 Red 10 8 10 Green 11 9 11 Blue 12 1...

Страница 14: ...4 47 Internal Program 13 120 127 47 50 Internal Program 14 128 135 50 53 Internal Program 15 136 143 53 56 Internal Program 16 144 151 56 59 Internal Program 17 152 159 60 62 Internal Program 18 160 1...

Страница 15: ...e care to prevent damaging any internal parts or effects 4 Clean all optical elements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamp...

Страница 16: ...mitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard...

Отзывы: