background image

AIMA-FRAS

OPTICAL ANALOG 

FORWARD RECEIVER

Online

Email: [email protected]
Website: technetix.com

2018-08/EN V1

Technetix Group Limited

Product user manual

Содержание AIMA-FRAS

Страница 1: ...AIMA FRAS OPTICAL ANALOG FORWARD RECEIVER Online Email customer service vdl technetix com Website technetix com 2018 08 EN V1 Technetix Group Limited Product user manual...

Страница 2: ...3 1 4 Block diagram 6 3 1 5 Order details 7 3 2 FRAR overview 8 3 2 1 Product description 8 3 2 2 Key features 8 3 2 3 Specifications 9 3 2 4 Order details 10 3 2 5 Block diagram 11 4 Module character...

Страница 3: ...setup 26 6 1 Port configuration screen 26 6 2 Restore factory defaults 31 6 3 Reboot 32 6 4 Alarms monitoring 33 6 4 1 Alarm Status Page 33 6 4 2 Module Operating Voltage and Temperature Alarm 34 6 4...

Страница 4: ...PSM Basic system management NMS3 EPSM Basic template management 1 2 Document conventions Before you use the manual please familiarise yourself with the format used in this manual Asterisk Points marke...

Страница 5: ...shed optical connectors must be used At any time there may be dangerous voltage inside the device DO NOT power up before the cover and the panels of the equipment are installed and the enclosure is cl...

Страница 6: ...utomatic gain control AGC which is based on broadband detection or through optional pilot signal detection The RF output AGC threshold level and the slope can be managed remotely 3 1 2 Product Key Fea...

Страница 7: ...in adjustment 0 20 dB Slope adjustment 0 7 dB ACG range input variation 10 dB AGC accuracy 0 5 dB over AGC range RF impedance 75 RF return loss 16 dB RF test point relative to RF output port 20 1 dB R...

Страница 8: ...on condensing Storage temperature 25 70 C Storage humidity 90 non condensing Dimensions W D H 24 6 410 152 5 mm Weight 0 88 kg Network management NMSE or through ASMM s web interface With the FBC Modu...

Страница 9: ...INPUT Optical input port ATTENUATOR Pre attenuator MID AMPLIFIER Mid stage amplifier SLOPE Slope control OUTPUT STAGE Post amplifier RF OUTPUT RF output port RF TEST 20 dB 20 dB RF output test port RF...

Страница 10: ...ut ports S Single 1 X FBC function 1 Y Optical connector type S SC APC 2 F FC APC L LC APC E E2000 APC Z Bandwidth 1G 45 1000 MHz standard 12 45 1218 MHz Notes 1 Option for FBC Management configuratio...

Страница 11: ...which is based on broadband detection The RF output AGC threshold level and the slope can be managed remotely 3 2 2 Product Key Features DOCSIS 3 1 Compatible with operating bandwidth up to 1218 MHz...

Страница 12: ...t panel LEDS SNMP traps Redundant switching time Typical 30 ms Link Performance 1 NTSC 4 CENELEC 42 ch 5 CNR 52 dB 52 dB CSO 68 dB 70 dB CTB 70 dB 70 dB General Power supply Powered via AIMA3000 backp...

Страница 13: ...Z Analog Forward Receiver Redundant Options X Optical input ports S Single 1 Y Optical connector type S SC APC F FC APC L LC APC E E2000 APC Z Bandwidth 1G 45 1000 MHz standard 12 45 1218 MHz Notes Op...

Страница 14: ...arameters Glossary OPTICAL INPUT Optical input port ATTENUATOR Pre attenuator MID AMPLIFIER Mid stage amplifier SLOPE Slope control OUTPUT STAGE Post amplifier RF OUTPUT RF output port RF TEST 20 dB 2...

Страница 15: ...12 2018 08 EN V1 Technetix Group Limited Product user manual AIMA FRAS Figure 4 1 module appearance 4 Module characteristics 4 1 Module appearance and port layout 4 1 1 Overview...

Страница 16: ...alarm Red 3 OPT IN LED Optical input signal status indicator ON Green Input signal slightly high low Orange Input signal too high low Red 4 RF OUT LED RF output signal status indicator ON Green Output...

Страница 17: ...able 4 2 FRAS rear panel functions Item Number Item Description 1 RF output port Forward RF signal output port 2 Air vent Air vent allowing air to flow out of the module 3 Multi pin connector Power su...

Страница 18: ...for installation Table 5 1 Necessary equipment and tools for installation 5 2 Unpacking Unpack the module Keep the packaging materials for future transport needs Check the package manifest record the...

Страница 19: ...ce when inserting the module but ensure the RF connectors at the rear of the module are securely connected with the chassis s RF connectors CAUTION The module MUST be installed correctly to ensure a p...

Страница 20: ...sis has a Sliding Fiber Guide to help the operator to arrange the cables For the specific steps to connect the fibre please refer to the instructions in section 5 4 1 5 4 1 Using the sliding fibre gui...

Страница 21: ...3 Then lift up the handle and slide the fibre guide out of the front of the chassis Figure 5 5 lift up the handle and slide the fibre guide out of the front of the chassis Figure 5 4 pull the panel DO...

Страница 22: ...tor When using the sliding guide put the fibre connector in the clip and slide it in from the rear to the front through the chassis Ensure that the optical fibre tail does not become trapped or pulled...

Страница 23: ...and future replacement of optical fibres Along the front of the chassis there are cut outs for keeping the optical fibres in position 1 When organizing the optical fibres lift up the metal flap at the...

Страница 24: ...Technetix Group Limited Product user manual AIMA FRAS 2 Use the Fibre Guide Tool to organize the cables and wires in the fibre tray to prevent tangles and the blocking of the guide rails Figure 5 10...

Страница 25: ...p and then use a lint free cloth dampened with a static dissipative solvent to clean the angled surface Dry the surface using a dry lint free cloth To clean the front panel optical port use a special...

Страница 26: ...put port align the raised tab on the connector with the slot in the port Insert the connector until the connector is securely held in place indicated by a clicking sound Figure 5 12 connecting the opt...

Страница 27: ...of redundancy cable and its brace to the brace mounting holes on chassis by tighting the securing screw as shown in figure d 5 6 Check module LEDs When the module has been installed and power is supp...

Страница 28: ...ht 5 8 Test the RF output signal After confirming that the module s input optical signal is within the normal range login into ASMM s web interface to set the appropriate RF gain slope parameters A sp...

Страница 29: ...provides the information regarding the ASMM s web interface For NMSE configuration methods please refer to the NMSE manual 6 1 Port configuration screen After logging in to the AIMA ASMM controller s...

Страница 30: ...e Information Model HW assembly no FW version firmware version Serial No FW part no firmware package number Configuration Alarm control Master alarm control switch ON OFF Alarm setting Critical high A...

Страница 31: ...that AGC is enabled and operating in range Enable Major Enable Minor Disable Parameter Description Input wavelength User configurable field to indicate at which optical wavelength the FRAS is operati...

Страница 32: ...for the designated transmitter In the FPAS Port configuration screen Output Gain Control Slope Control Input Gain Control Gain Control Type and Alarm Settings become available Total Gain is calculated...

Страница 33: ...stable range the red status indicator will be shown AGC reference AGC reference level when the module is working under the AGC status Configuration Input wavelength Changeable manual input 1260 1620 n...

Страница 34: ...parameter table shown in Table 6 3 Figure 6 3 Factory defaults webpage Name Configuration Factory Default Value After Software Upgrade Alarm control ON OFF ON Same as the configuration before upgrade...

Страница 35: ...oted remotely see Figure 6 4 Detailed operations Click the Modules tab select the FRAS and then click the Apply button next to Reboot Next click on Submit to confirm and then the module will automatic...

Страница 36: ...l the module alarms are shown on the alarm page If an alarm occurs the operator can view the associated pages to find more detailed alarm information 6 4 1 Alarm status pages Click the Alarms tab on t...

Страница 37: ...Modules tab the operator can view the module temperature and power supply voltage alarms The operator can view the status indicators to check if the module is functioning properly The status has three...

Страница 38: ...AIMA FRAS 6 4 3 Module Port Alarms Click on the Module s Port label on the right column as shown in Figure 6 7 The module s optical input status RF output power status input status and AGC status can...

Страница 39: ...x as shown in Figure 6 8 toggles the alarms When the check box is checked detection ON the associated alarm is enabled the text in the textbox are always grey and cannot be changed The default alarm p...

Страница 40: ...ngs click the check box to toggle the various parameters The monitoring thresholds can be changed See Figure 6 9 Parameter Units Critical high HIHI Warning high HI Normal Warning low LO Critical low L...

Страница 41: ...d Indicators Lighting Conditions Power OFF Power off Power off All All OFF Initiating AM Power on Module power on Ppocess All Green slowly flashes No alarm Normal operation Normal All Green AM critica...

Страница 42: ...FBCM upgrade open the web as below click Choose File button at upgrade FBCM in slot x and navigate to the firmware file Select the file and then click the Start Upgrade button After the firmware has b...

Страница 43: ...Full Band Capture FBC module it enables the operator to capture and monitor the spectrum and QAM demodulation data including level of each channel SNR MER BER constellation and so on Operators can ge...

Страница 44: ...nter of spectrum Reference Set the reference level of the spectrum based on the fact And the spectrum peak need lower than the reference level so that the spectrum can be fully shown in the spectrum T...

Страница 45: ...Group Limited Product user manual AIMA FRAS Figure 6 13 FRAS S M QAM analyser webpage Figure 6 14 FRAS S M QAM MER webpage 6 7 2 QAM analyser Click QAM Analyser on the left open the QAM Analyser inte...

Страница 46: ...nex B Annex A is European standard Annex B American Standard Annex should be the same as the QAM signal source Modulation Set modulation mode 64 QAM and 256 QAM is optional Stick Add after set the cha...

Страница 47: ...locked constellation result The points are increased and it will count again via sticking Start or refresh the web The QAM results show the RF level SNR MER Pre BER and Post BER results Figure 6 16 c...

Страница 48: ...ions If there are multiple FRAS S M modules the FBC port discovery time will be longer Refreshing each spectrum port needs two seconds If there are multiple spectrum ports enabled each port will be re...

Страница 49: ...and Redundancy Status show the module s redundancy status You can configure the module s redundancy in the box Unit Redundancy Configuration Redundancy Enable is for enabling or disabling the function...

Страница 50: ...FRAR S the module name Redundancy the redundancy alarm page will appear In this page you can see the redundancy alarm status of the module and each port s local status and configuration status Click o...

Страница 51: ...tical power is within the normal range If this fault still exists when the input optical power is normal contact Technetix Technical Support Staff Input optical port status is red Input port optical p...

Страница 52: ......

Отзывы: