12
TL-A8O-50W User Manual
www.tlnetworx.com
3.
Any dot “.” after the letters is part of the commands.
4.4
TCP/IP Control
TL-A8O-50W provides a TCP/IP port for IP control.
Default settings: IP: 192.168.0.178; Subnet Mast: 255.255.255.0; Gateway: 192.168.0.1; Port:
4001.
IP and gateway can be changed, but the port cannot be changed.
Connect the Ethernet port of control device to the TCP/IP port of TL-A8O-50W, and set same
network segment for the two devices. Users are able to control the device via a web-based GUI
or TCP/IP communication software.
4.4.1
Control Modes
TL-A8O-50W can be controlled by PC without Ethernet access or PC(s) within a LAN.
l
Controlled by PC without Ethernet access
Connect a computer to the TCP/IP port of the TL-A8O-50W and set its network segment to the
same as the TL-A8O-50W.
l
Controlled by PC(s) in LAN
Connect TL-A8O-50W, a router and several PCs to setup a LAN (as shown in the following figure).
Set the network segment of TL-A8O-50W to the same as the router’s, then PCs within the LAN
are able to control TL-A8O-50W.
Same network
segment as the
TL-A8O-50W