GENERAL SAFETY 

 

2i: GENERAL SAFETY STANDARDS 

 
The Chiller in question is manufactured conforming with the European Directives relevant to low tension 

73/23-

93/68/EEC, 

and electromagnetic compatibility 89

/336/EEC; 

EN60335- 1, EN60335-2-24, EN55014, EN61000-

3-2, EN61000-3-3, EN55104. 

 

2ii: LOCATION REQUIREMENTS 

 
It is necessary that electrical supply to the freezer be provided as specified on the data plate of your Techfrost 
freezer.  Each freezer comes with electrical cord and power connector as required.  
 

 

The chiller and its control board should only be operated by adults. 

 

Installation and any other operation (including a possible extension of the power cable) must be carried 
out by 

authorized personnel

 only.  

 

Maintenance  and  service  have  to  be  carried  out  by  qualified  technicians.  Only  factory  replacement 
parts should be used for repairs. 

 

Do not attempt to modify the chiller yourself; the operation could be dangerous. 

 

In  order  to  avoid  the  risk  of  over-heating  of  the  compressor  and  consequent  damage,  it  is  crucial  to 
allow sufficient air circulation around the machine. 

 

The  chiller  should  be  placed  so  that  there  remains  sufficient  space  for  air  circulation  in  the  back  (at 
least 10 cm or approximately 4in.). 

 

While installing or transporting the unit, take care in ensuring that the cord is not crimped or kinked. 
Before  any  cleaning  or  installing  operation,  remember  to  switch  the  machine  off  and  disconnect  the 
plug. Make sure you do not pull the cord. 

 

The deep-freezing system, placed on the back and inside the machine, contains a refrigerant solution. 
Do not use sharp objects in the vicinity of the evaporator, cooling plate, or near the pipe coils (located 
on the back and inside the chiller). The accidental perforation of the system could cause damage to the 
unit. 

 

Wait for at least 30 minutes before connecting the plug to the power point after sitting freezer in place. 
If the chiller has been transported in the horizontal position, be sure to keep it vertical for at least four 
hours.  This allows the oil contained in the compressor to be transferred back to its original location. 

 

WARNING!  Do  not  keep  explosive  gases  and  liquids  or  glass  bottles  in  the  machine.  Doing  so  may 
result in damages to persons or things.  

 

When the 

“DEEP-FREEZING”

 process has concluded, dry gloves or cloths should be used to remove 

containers from the machine. 

 

Do  not  open  the  machine  door  while  executing  its  working  cycle.  Doing  so  may  prevent  cycle 
completion.  

 

The constructor is not liable for damages arising from improper use or installation, connection to non-
authorized equipment, use of non-original fittings, or tampering by non-authorized personnel.  

 

CAUTION: The Blast Chiller/Blast Freezer must be connected to an electrical supply source that matches 
the data plate on the machine.  Make sure it is level and always use qualified personnel to install, repair 
and service your Chiller. 
 
 

3)

 

INSTALLATION 

 

3i: INTRODUCTION 

 
This manual aims to provide the user with all the necessary information to correctly use and maintain the chiller.  
 
Before  use,  carefully  read  all  the  instructions  given  in  this  manual.  The  manufacturer  shall  decline  all 
responsibility for operations and use which disregard the instructions herein.  
 

Содержание JOF 23

Страница 1: ...y Street 5C Wendy Ct Greensboro NC 27409 Mailing PO Box 18542 Greensboro NC 27419 P 336 856 2919 F 336 217 8838 Email Sales AdvancedGourmet com Web www AdvancedGourmet com JOF ONE JOF 23 JOF 23 A 110V OWNER S MANUAL ...

Страница 2: ...TY STANDARDS 6 3iv INSTALLATION INSTRUCTIONS 6 3v CONNECTING TO THE POWER SUPPLY 6 4 ADVICE FOR PROPER USE OF THE EQUIPMENT 7 5 GENERAL OPERATION 7 5i PRE COOLING 7 5ii CORE PROBE Optional 7 5iii LIDS AND CONTAINERS 7 5iv POSITIONING OF THE PRODUCT 7 5v CONSERVATION 7 5vi STANDARD USE INSTRUCTIONS 7 6 KEYPAD IDENTIFICATION 9 7 USER FUNCTIONS 10 8 FUNCTIONS OF THE BLAST CHILLER BLAST FREEZER 13 8i ...

Страница 3: ...eb www AdvancedGourmet com Distributed By P a g e 3 9i PRELIMINARY INSTRUCTIONS 15 9ii ALARMS HACCP INFORMATIONS DISPLAY 16 9iii CANCELLATION OF HACCP ALARM INFORMATION 17 10 COMPRESSOR WORKING HOUR CALCULATION 18 10i COMPRESSOR WORKING HOUR DISPLAY 18 10ii COMPRESSOR WORKING HOURS CANCELLATION 18 11 SETTING 18 11i REAL DAY AND HOUR SETTING 18 ...

Страница 4: ...t system of air circulation Constant temperature from shelf to shelf Advanced cooling system for a quick cold penetration to the product s core Maintenance of a high humidity rate in the chilled product 80 85 thus avoiding drying or dehydration eliminating the risk of weight loss Excellent thermic conditions during transfer to the conservation cell A product is at peak quality at the point that it...

Страница 5: ...connect the plug Make sure you do not pull the cord The deep freezing system placed on the back and inside the machine contains a refrigerant solution Do not use sharp objects in the vicinity of the evaporator cooling plate or near the pipe coils located on the back and inside the chiller The accidental perforation of the system could cause damage to the unit Wait for at least 30 minutes before co...

Страница 6: ...guarantee working efficiency and safety when the Chiller is in use CAUTION When transporting or moving the Chiller to the installation site do not push or drag it Lift it and position it on a trolley to avoid overturning LOCATION Locate the Chiller in a ventilated area distant from heat sources such as radiators air conditioning units deep fryers and ovens Make sure the Chiller is located at a dis...

Страница 7: ... precool the internal parts prior to use 5ii CORE PROBE Optional The core probe shall be properly positioned in the core of the thicker portion of the product Its point shall neither come out nor touch the pan The probe shall be cleaned before starting any cycle in order to prevent contaminations PLEASE NOTE YOUR PARTICULAR MACHINE MAY MAY NOT HAVE A CORE PROBE 5iii LIDS AND CONTAINERS Do not cove...

Страница 8: ...ycle completion BLAST CHILLING 0 C Make sure the device is on Press the BLAST CHILLING key The LED will flash You can modify the default temperature setting of 0 C by pressing the key to increase the temperature or the key to decrease the temperature This option is active only before starting the program Press the key ON OFF to start the BLAST CHILLING The BLAST CHILLING phase will last 90 minutes...

Страница 9: ... is active only after having started the program Once the completion of the 240 minute cycle the device will pass into conservation setpoint 20 C WARNING The BLAST FREEZING HARD phase is set by default If the HARD key is pressed before starting the cycle HARD is stopped and the SHOCK FREEZING will cease even if in the BLAST FREEZING phase w temperature setting of 0 C GELATO PROGRAM To use the shoc...

Страница 10: ...e lighting of the device is the transition from the state stand by to the state on the state turning of the device is the transition from the state on to the state stand by If an interruption of the feeding occurs during the state stand by or during the state on the restoration of the feeding device will propose the same state If an interruption of the feeding occurs during the state run the resto...

Страница 11: ...l show the temperature of the cell To leave the procedure please operate in the following way 5 Press and release the BLAST CHILLING key or do not operate for 15 seconds The display will again read PB1 6 Press and release the UP key or the DOWN key until the display matches the state from paragraph 8iic or do not operate for 60 seconds e Evaporator temperature display Please operate in the followi...

Страница 12: ... is not jammed and that a procedure is not in progress 3 Keep the UP key pressed for 4 seconds The LED will switch on If the temperature of the evaporator upon starting the defrosting cycle is not above that established with the parameter d2 the cycle will not be activated If the parameter P4 is set to 1 the defrosting cycle won t begin h Keyboard Block unblock To stop the keyboard please operate ...

Страница 13: ...wing paragraphs Every cycle of operation can be preceded by a pre cooling cycle Please refer to paragraph 7i Pre cooling 8ii BLAST CHILLING AND CONSERVATION The temperature blast chilling and conservation cycle it is composed by the followings two phases blast chilling conservation When the first phase finishes the device automatically passes to the following one To start the cycle please operate ...

Страница 14: ...s set to 1 the display will show the blast chilling end temperature It is also possible to set this value through the parameter r3 5c Please press and release the UP key or the DOWN key within 15 s to modify the value of the parameter 8iv BLAST FREEZING AND CONSERVATION The temperature blast freezing cycle and conservation cycle are distinguished by the followings two phases blast freezing conserv...

Страница 15: ...r8 5 2 If the parameter r19 is set to 1 the display will show the end blast freezing temperature It is possible to set this value through the parameter r4 5 3 Press and release the UP key or the DOWN key within 15 seconds to modify the value of the parameter 8vi PRE COOLING START Every cycle of operation can be preceded by a pre cooling phase To start the pre cooling phase please operate in the su...

Страница 16: ...ms code PF please make sure the device is in the state stand by or in the state on before the feeding If the duration of the feeding interruption alarm code PF causes the clock error code rtc the device will not memorize the date the time when the alarm starts or the duration of the alarm The LED HACCP gives information about the alarms HACCP memory state please consult the paragraph 10 1 signals ...

Страница 17: ...splay of information 7 Press and release the START STOP key the display will again show the code of selected alarm To leave the procedure 8 Conclude the display of information 9 Press and to release the UP key or the DOWN key until the display shows the appropriate state from paragraph 8iic the display or do not operate for 60 s 9iii CANCELLATION OF HACCP ALARM INFORMATION Please operate as follow...

Страница 18: ...se the UP key or the DOWN key until the display shows the suitable state from paragraph 8iic the display or do not operate for 60 seconds 10ii COMPRESSOR WORKING HOURS CANCELLATION Please operate in the following way 1 Make sure that the keyboard is not jammed and that a procedure is not in progress 2 Press the DOWN key for 1 second the display will show the first available label 3 Press and relea...

Страница 19: ... month the display will read dd followed by the two numbers of the month 9 Press and release the UP key or the DOWN key within 15 seconds to modify the value To set the hour 10 Press and release the BLAST CHILLING key during the formulation of the day of the month the display will read hh followed by the two numbers of the time 11 Press and release the UP key or the DOWN key within 15 seconds to m...

Страница 20: ...Wendy Ct Greensboro NC 27409 Mailing PO Box 18542 Greensboro NC 27419 P 336 856 2919 F 336 217 8838 Email Sales AdvancedGourmet com Web www AdvancedGourmet com Distributed By P a g e 20 JOF 23 23 A EXPLODED VIEW ...

Страница 21: ...C Wendy Ct Greensboro NC 27409 Mailing PO Box 18542 Greensboro NC 27419 P 336 856 2919 F 336 217 8838 Email Sales AdvancedGourmet com Web www AdvancedGourmet com Distributed By P a g e 21 JOF ONE EXPLODED VIEW ...