Page 21
•
Enabled
– enable/disable general Zone APB flag setting.
•
Enable in offline mode
– if the option is not set, the module operates in offline mode like
if the APB function was not implemented.
•
Open door after APB Zone alarm
– if the option is enabled, the Door open function is
performed after the Zone APB alarm is raised.
•
Set opposite APB flag after APB alarm
– if the Zone APB alarm is raised, the Zone APB
alarm flag is set for both directions (entry reader and the module itself) of the module.
•
Clear opposite APB flag
– if the option is enabled, passing at the reader module causes
a reset of the Zone APB alarm flag at the opposite direction.
6.12
Duress PIN
This function is implemented since the FW version 5.2.
To use the
Duress PIN
code entering function, use the user’s standard PIN code with the
last digit increased by 1. If the last digit equals 9, it is changed to 0 when using this function.
6.13
Disabling function
This function is implemented since the
FW version 5.08
.
The
module disabling function
can be set at the second input and at the third input / output
port. The logic of the function is individually configurable. The function is active whenever
one or both of the configured inputs are active.
The module behavior is as described below when the disabling function is active:
•
User with access driven by a time schedule cannot run the door open function
•
User with access always granted is not affected by the disabling function
•
Remote door open function cannot be performed
•
Remote identification with ID is disabled for users with access driven by a time schedule
The disabling status changes and disabled actions are logged in the events archive.
6.14
Reading synchronization
Since the
FW version 5.09
the reading synchronization of a
couple of TECHFASS readers
is
implemented, enabling to
cancel the mutual disturbance
of the modules. The reader module
offers to use the
IO synchronization
in both
MASTER
and
SLAVE
mode. The
input/output
port 3
is used as the
synchronization signal
.
6.15
Online authorization
Since the
FW version 5.11
the
Online authorization of ID
can be used in APS mini Plus
system. When the feature is used, the ID validity is resolved in connected PC. To be able to
use this authorization mode, the reader module has to be equipped with a
MLO
license.