APS mini Plus reader modules 

User’s guide 

© 2004 – 2019, TECH FASS s.r.o., Věštínská 1611/19, 153 00 Prague, Czech Republic, www.techfass.cz, [email protected] 

(Date of release: 2019/06/03, valid for FW version 5.12) 

Содержание 53465000

Страница 1: ...65 APS mini Plus reader modules User s guide 2004 2019 TECH FASS s r o V t nsk 1611 19 153 00 Prague Czech Republic www techfass cz techfass techfass cz Date of release 2019 06 03 valid for FW version...

Страница 2: ...s 6 4 5 Mounting and removal the module 7 5 Setting parameters of the reader module 8 5 1 Configurable parameters 8 5 2 Reader module parameters setting 8 6 Reader module functioning 9 6 1 Door Open f...

Страница 3: ...e of the APS mini Plus system In effect the number of lines is not limited The reader module is designed both for outdoor and indoor use 2 1 MREM 65 BK reader module The MREM 65 BK modules are deliver...

Страница 4: ...N A ID technology typical reading range EM Marin 8 cm with ISO card Real time clock Yes with 24 hrs back up Memory Cards 2 000 ID 2 programming cards Events 3 400 Time schedules 64 Inputs 1st input L...

Страница 5: ...working in standard operating mode The module must be paired with appropriate reader module before use 3 5 Mechanical design Mechanical design Weight 0 202 kg Operating Temperature 25 60 C Humidity Ma...

Страница 6: ...ng mode Fast switching red green Address setting mode RS 485 BUS testing mode Single flash green ID media reading D2 Yellow Continuously lit flashing Programming mode Short flashing with 1s per Indica...

Страница 7: ...o relevant fasteners see Pic 3 Then set the housing on the upper part of the base and rotate the housing until the both parts snaps down It is recommended to place an installation box for connection o...

Страница 8: ...s Acoustic signalization time Forced door 0 255 s 30 s Acoustic signalization time Door ajar 0 255 s 0 s Acoustic signalization time APB alarm 0 255 s 0 s Signalization time Card alarm 0 255 s 30 s An...

Страница 9: ...hed and the beeper is activated when not disabled when the Door Open function is activated The beeper stays active until the door is opened or the preset door lock release time has elapsed see configu...

Страница 10: ...ith setting of the signaling timer 0 occurs the alarm output is activated It can control any alarm device directly or it can be processed further After terminating all alarm conditions the alarm outpu...

Страница 11: ...er module s memory when the module goes online When a programming card is read while in either online or offline mode the module goes into programming mode 6 5 Read ID media format 6 5 1 EM Marin ID m...

Страница 12: ...erating mode Since the FW version 5 09 the reading synchronization of a couple of TECHFASS readers is implemented enabling to cancel the mutual disturbance of the modules The reader module offers the...

Страница 13: ...for inserting the reader goes into programming mode One by one read the cards which are to be granted access About 15 seconds after inserting the last card the reader module goes back into standard o...

Страница 14: ...s into programming mode which is indicated by slow flashing of yellow LED Read the programming card for inserting 5 times in a row the reader will go into Deleting cards above or below mode indicated...

Страница 15: ...adding and deleting cards should be stored in the table Following example shows correct usage of the programming cards and proper filing of the actions Inserting 5 new cards using the procedure from c...

Страница 16: ...eleting all cards using the procedure described in chapter 6 7 4 it is necessary to create a new filing table 6 8 ID expiration function This function is implemented since the FW version 5 0 It is pos...

Страница 17: ...to the ID after passing at the reader module If the users uses the ID at the address during the timer for the ID is running the Time APB alarm is raised Following parameters affect the Time APB functi...

Страница 18: ...Remote identification with ID is disabled for users with access driven by a time schedule The disabling status changes and disabled actions are logged in the events archive 6 12 Reading synchronizati...

Страница 19: ...lock diagram for access right evaluation can be seen in Pic 6 Pic 6 Simplified access rights evaluation VALID UNKNOWN ID FOUND ACCESS DRIVEN BY TIME SCHED ACCESS ALWAYS GRANTED HOLIDAY ACCESS GRANTED...

Страница 20: ...er 51900200 and attach it in the hole with appropriate mastic to ensure the top surface of the magnet matches with the wall surface Mount the reader module in formerly prepared holes mounted with plug...

Отзывы: