background image

 

being sucked back into the unit.  Also do not overfill the barrel and to lay the 
barrel on its side 

 

Do not smoke or use open flame when flammable materials are being dispensed 

 

This equipment is for indoor use only 

 

2

 

SYMBOL DEFINITIONS 

 

Symbol Definition 

 

Power On/Off 

      

 

Cycle Mode 

 

Timer 

 

     

 

Vacuum  

 

 

Pressure 

 
 

3

 

SPECIFICATIONS

 

 

Size 

152mm X 165mm X 178mm 
(6” X 6.5” X 7.0”) 

Weight 

1.2 kg (2.6lbs) 

Input Voltage 

24 VDC 

Rated Power 

10 W 

Air Input 

100 psi (6.9 bar) Max. 

Pollution Degree 

II 

Installation Category 

Indoor Use 

Altitude up to 2,000m (6,562ft) 

Operating Temperature 

0˚C to 50˚C (32˚F to 122˚F) 

Storage Temperature 

-10˚C to 60˚C (14˚F to 140˚F) 

Max. Relative Humidity 

80% for temperature up to 31˚C (87.8˚F) Decreasing 
linearly to 50% relative humility at 40˚C (104˚F) 

Air Output 

TS250 = 0-100 psi (0- 6.9 bar)  
TS255 = 0-15 psi (0-1 bar) 

Vacuum 

406mm (16”) of Hg 

Timer 0.020-60.000 

seconds 

Cycle Mode 

PURGE, TIMED 

Timing Repeat Tolerance 

+/- 0.001% 

Cycle Rate 

 600 cycles/min 

LCD 

16 X 2 display segments 

 

4

 
4

 

FEATURES 

Figure 1.0  

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

Items Description 

Power Button 

 

Mode Button

 

Counter Reset Button 

Display 

 

Air Pressure Gauge

 

Air Pressure Regulator 

 

Pulsed Air Outlet  

 

Vacuum Control 

Time Control Knob 

10 

Receiver head air hose holder 

11 

Foot Switch Receptacle 

12 

Power Receptacle 

13 

I/O Connection 

14 

Exhaust Port 

15 

Air Inlet  

16 

Cord Lock 

1

7

6

5

3

4

15

16

14

11

12

9

2

10

8

13

Содержание TS250

Страница 1: ...nintended applications of its equipment Unintended uses may result form taking the following actions Making changes to equipment that has not been recommended in the User Guide Using incompatible or damaged replacement partsUsing unapproved accessories or auxiliary equipment 1 2 Safety Precautions Do not operate this unit in excess of maximum ratings settings Always wear appropriate personal prote...

Страница 2: ...o 122 F Storage Temperature 10 C to 60 C 14 F to 140 F Max Relative Humidity 80 for temperature up to 31 C 87 8 F Decreasing linearly to 50 relative humility at 40 C 104 F Air Output TS250 0 100 psi 0 6 9 bar TS255 0 15 psi 0 1 bar Vacuum 406mm 16 of Hg Timer 0 020 60 000 seconds Cycle Mode PURGE TIMED Timing Repeat Tolerance 0 001 Cycle Rate 600 cycles min LCD 16 X 2 display segments 4 4 FEATURES...

Страница 3: ...n 1 To Air Source 2 Air Filter Not included 3 Power Adapter 4 Foot Switch 2 1 3 4 6 6 3 Cycle Counter The cycle counter records the numbers of dispense cycle being activated Up to 65 535 cycles can be recorded This number is shown at the lower right hand corner of the LCD Press the Counter Reset button 3 to clear the counter 7 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTION LCD does not light No...

Страница 4: ...edispensing co uk 2 INHALTSVERZEICHNIS Seite 1 Sicherheitshinweise 2 3 2 Erläuterung der Symbole 3 3 Spezifikationen 4 4 Hauptkomponenten 5 5 Anschluss des Gerätes 6 6 Setup Anleitung 6 7 Fehlerbeseitigung 7 8 Wartung 8 9 Ersatzteile und Zubehör 8 10 Garantie 8 11 I O Konfiguration und Schalter zum Beenden des Zyklus 8 1 SICHERHEITSHINWEISE 1 1 Bestimmungsgemäßer Gebrauch WARNUNG Wird dieses Gerät...

Отзывы: