ST – 280 user’s manual 

 

 

II.

 

Device Description 

Application of the ST-280 room regulator provides convenient steering and control of room temperature, 
boiler, tank and mixing valves directly from home without the need to go down to the boiler room. The 
controller  is  adapted  to  cooperate  with  various  kinds  of  main  controllers  equipped  with  RS 
communication: standard controllers, pellet controllers (equipped with ignition switch) and installation 
controllers. 
 

Its large, legible, colourful touch-screen display allows for convenient operation of the regulator 

and  modulation  of  its  parameters.  An  additional  advantage  is  the  possibility  to  load  photos  to  the 
controller's memory which will be displayed as a screensaver.  
 
The ST-280 room regulator enables: 

 

Control of room temperature  

 

Control of the CH pump temperature 

 

Control of the DHW temperature 

 

Control  of  the  mixing  valves  temperature  (available  in  cooperation  with  an  additional  valve 
module) 

 

View of external temperature  

 

Weekly heating program 

 

Alarm clock 

 

Parental lock 

 

Display of current boiler temperature and room temperature 

 
 
Controller equipment: 

 

Large, legible, colourful, touch-screen display 

 

Built-in room sensor 

 

RS communication cable for boiler controller  

 

RS wireless communication module – ST-260 (additional option) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ST-280

Страница 1: ...Tech 1...

Страница 2: ...ration of the Controller 8 IVa Operating Principle 8 IVb Main Screen Description 8 V Controller Functions Menu Options 12 VI a Time 14 VI b Securities 15 VI c Screen 16 VI d Weekly Control 17 VI e Boi...

Страница 3: ...eld liable for damage caused by negligence WARNING Live electrical device Before any activities related to power supply connecting wires device installation etc you must ensure that the regulator is n...

Страница 4: ...n of the regulator and modulation of its parameters An additional advantage is the possibility to load photos to the controller s memory which will be displayed as a screensaver The ST 280 room regula...

Страница 5: ...the relevant qualifications WARNING There is a danger of fatal electrical shock from touching live connections You must disconnect the electrical connection and protect against accidental connection b...

Страница 6: ...uts in accordance with colours of wires The cable is then connected to RJ12 connector which you should plug into the regulator power supply the place of connection is marked on the scheme as point 2 t...

Страница 7: ...ordance with colours of wires This cable is then connected to the RJ12 connector and should be plugged into the v2 module the place of connection is marked on the scheme as point 2 there is an additio...

Страница 8: ...es etc IVb Main Screen Description The controller is equipped with a large touch screen display The main screen displays the current state of basic parameters for the boiler Depending on the user s se...

Страница 9: ...of the valve not being installed the room regulator will display an icon 9 Boiler 1 temperature current and set clicking the screen in this area will switch you to the menu which enables you to introd...

Страница 10: ...on the main controller 6 Current room temperature 7 Current time and date 8 Right parameters panel 9 Buttons allowing change of active view of parameters panel 10 Access to the controller menu 11 Lef...

Страница 11: ...s panel it is possible to change the set temperature of the boiler Valves data panel View of the current temperature and set temperature of valve 1 2 3 or 4 after clicking on this panel it is possible...

Страница 12: ...r after clicking on this panel it is possible to change the pumps operation mode A selection can be made from among the following modes Home heating Priority parallel pumps summer mode with additional...

Страница 13: ...Screen View Panels Screen Installation Screen Night from Hour Day from Hour Brightness During the Day Brightness at Night Weekly control Activated Disabled Settings Boiler Control Submenu Subject to...

Страница 14: ...ser to set the current time according to which the regulator will then operate Date This function allows the user to set the current date according to which the regulator will then operate Alarm clock...

Страница 15: ...ich the alarm clock is to be activated Controller screen view at the time of activation of the alarm clock VI b Securities After clicking on the Securities icon on the main menu you will see the panel...

Страница 16: ...creen Time out after expiration of the set idle time the screen will switch to stand by function Import of Photos Any photos you want to import to the controller s memory must be first prepared by mea...

Страница 17: ...ss during the day and at night VI d Weekly Control This function allows you to change the set temperature of the room in a day night cycle You can set each day you can set the device to change to a sp...

Страница 18: ...ller between Home heating Priority parallel pumps summer mode More detailed descriptions of these operating modes can be found in the operation manual for the boiler controller Submenu for the pellet...

Страница 19: ...de the room and in accordance with the schedule of the boilers daily operations The current temperature inside the room is the priority for boiler under operation in this mode if the temperature in th...

Страница 20: ...for changing the language for the user VI g Information about the Operating Program By clicking on this icon the display will show the boiler manufacturer s logo along with the software version VI h...

Страница 21: ...selection is made the Boiler control submenu will be changed I Alarms The ST 280 room temperature regulator will signal all alarms generated by the main controller When the alarm activates the room re...

Страница 22: ...g provisions of Low Voltage Directive LVD 2006 95 EC the Act of 13th April 2007 on Electromagnetic Compatibility Official Journal 07 82 556 implementing provisions of Directive EMC 2004 108 EC and the...

Страница 23: ...y received a registry number assigned by the Chief Inspector of Environmental Protection The symbol of a crossed out disposal bin on the product means that the product must not be thrown out to genera...

Страница 24: ...ST 280 user s manual 24...

Отзывы: