6.
Wait for a moment (ca. 1min) and check if the IP address has been assigned. Go to the "IP Address" tab and check if
the value is different than 0.0.0.0/ -.-.-.- .
a.
If the value still indicates 0.0.0.0 / -.-.-.-.- check the network settings or the Ethernet connection between the
Internet module and the device.
7.
After correctly assigning the IP address, we can start registering the module to generate the code that is required to
assign it to an application account.
4.5.
MANUAL MODE
This function allows you to control the operation of individual devices. The user can manually switch on each of the devices:
pump, voltage-free contact and individual valve actuators. It is recommended to use manual operation mode, to check the
correct operation of the connected devices at the first start-up.
4.6.
EXTERNAL SENSOR
CAUTION
This function is only available when an external sensor has been registered in the EU-L-X WiFi controller.
You can connect an external temperature sensor to the EU-L-X WiFi controller, which allows you to switch on the weather
control, by:
➢
Sensor Selection
–
You can select either a NTC wired sensor or the C-8zr wireless sensor. Wireless sensor requires
registration.
➢
Calibration
- Calibration is performed at installation or after prolonged use of the sensor if the temperature
measured by the sensor deviates from the actual temperature. Adjustment range is from -
10°C to +10°C with a step
of 0.1°C.
In the case of a wireless sensor, the subsequent parameters relate to the range and level of the battery.
4.7.
HEATING STOPPING
Function to prevent actuators from turning on at specified time intervals.
➢
Date settings
•
Heating deactivation
–
Set the date from which the heating will be switched off
•
Heating activation
- setting the date from which the heating will be switched on
➢
Weather control
-
When the external sensor is connected, the main screen will display the external temperature
and the controller menu will display the mean external temperature.
The function based on the outside temperature allows determining the mean temperature, which will work on the
basis of the temperature threshold. If the mean temperature exceeds the specified temperature threshold, the
controller will switch off the heating of the zone in which the weather control function is active.
•
On
–
to use the weather control, the selected sensor must be enabled.
•
Averaging time
–
the user sets the time on the basis of which the mean outside temperature will be
calculated. Setting range is from 6 to 24 hours.
•
Temperature threshold
–
this is a function protecting against excessive heating of the given zone. The
zone in which the weather control is switched on will be blocked from overheating if the mean daily
outdoor temperature exceeds the set threshold temperature. For example, when temperatures rise in the
spring, the controller will block unnecessary room heating.
•
Average external temperature
–
temperature value calculated on the basis of the
Averaging time
.