I.

 

SAFETY 

Before using the device for the first time the user should read the following regulations carefully. Not obeying the rules 
included in this manual may lead to personal injuries or controller damage. The user’s manual should be stored in a safe 
place for further reference. 

 In order to avoid accidents and errors, it should be ensured that every person using the device has familiarized themselves 
with the principle of operation as well as security functions of the controller. If the device is to be sold or put in a different 
place,  make  sure  that  the  user’s  manual  is  stored  with  the  device  so  that  any  potential  user  has  access  to  essential 
information about the device. 

The manufacturer does not accept responsibility for any injuries or damage resulting from negligence; therefore, users 
are obliged to take the necessary safety measures listed in this manual to protect their lives and property. 

       

WARNING 
 
 

 

High  voltage!  Make  sure  the  regulator  is  disconnected  from  the  mains  before  performing  any  activities 
involving the power supply (plugging cables, installing the device etc.) 

 

The device should be installed by a qualified electrician. 

 

The regulator should not be operated by children. 

 

WARNING 

 

 

The device may be damaged if struck by a lightning. Make sure the plug is disconnected from the power 
supply during storm. 

 

Any use other than specified by the manufacturer is forbidden. 

 

It is recommended to periodically check the condition of the device. 

 
 

Changes  in  the  merchandise  described  in  the  manual  may  have  been  introduced  subsequent  to  its  completion  on 
13.07.2021. The manufacturer retains the right to introduce changes to the structure or colours. The illustrations may 
include additional equipment. Print technology may result in differences in the colours shown.  

 

 

We are committed to protecting the environment. Manufacturing electronic devices imposes 
an obligation of providing for environmentally safe disposal of used electronic components 
and  devices.  Hence,  we  have  been  entered  into  a  register  kept  by  the  Inspection  for 
Environmental Protection. The crossed-out bin symbol on a product means that the product 
may not be disposed of to household waste containers. Recycling of waste helps to protect 
the environment. The user is obliged to transfer their used equipment to a collection point 
where all electric and electronic components will be recycled. 

 

 

Содержание EU-297 v2

Страница 1: ...EU 297 v2...

Страница 2: ...VII Device description 11 1 Main screen description 12 VIII Controller functions 13 1 Block diagram main menu 13 1 1 Clock 13 1 2 Pre set day temperature 13 1 3 Day from 14 1 4 Pre set night temperatu...

Страница 3: ...ce etc The device should be installed by a qualified electrician The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disco...

Страница 4: ...e pre set value The EU 297v2 controller functions Maintaining pre set room temperature Manual mode Day night mode Control of the floor sensor Possibility of pairing with the EU MW 3 module Controller...

Страница 5: ...ver included in the controller set mounted near the heating device Hardware versions 1 EU 297 v2 RB EU 297 v2 RBN wireless version powered with two AAA 1 5V batteries 2 EU 297 Z v2 RZ EU 297 v2 RZN wi...

Страница 6: ...two wire communication cable should be connected to the appropriate connectors on the receiver The EU 297v2 room regulator may be used as a wall mountable panel In order to mount it place the rear pa...

Страница 7: ...ng device with a two core cable The cable connection of both devices is shown in the diagram below NOTE The regulator is powered with batteries it is recommended to check the batteries from time to ti...

Страница 8: ...F THE REGULATOR POWER SUPPLY 230V The room regulator may be used as a wall mountable panel In order to mount it place the rear part of the controller in the mounting box on the wall insert the regulat...

Страница 9: ...EU 297 9 The room regulator should be connected to the heating device with a two core cable The cable connection of both devices is shown in the diagram below heating device heating device...

Страница 10: ...erature fails to reach the pre set value the heating device is switched on NOTE In case of no communication e g due to discharged battery the receiver automatically disables the heating device after 1...

Страница 11: ...y The user may set different temperature values for the daytime and nighttime as well as define the exact time of entering day mode and night mode In order to activate this mode press MENU button unti...

Страница 12: ...ton to enable manual mode or to set calibration Press the MENU button to move on to edit next parameters 1 MAIN SCREEN DESCRIPTION 1 Battery level battery version 2 Maximum minimum floor temperature t...

Страница 13: ...AGRAM MAIN MENU 1 1 CLOCK In order to set the time press MENU button until the clock settings appear on the screen The settings concern the flashing parameter Use or to set the hour Next press MENU to...

Страница 14: ...to define the exact time of entering the night mode To configure this parameter press MENU until a flashing icon appear on the screen Use or to set the time of night mode activation 1 6 HYSTERESIS Roo...

Страница 15: ...es the tolerance for the maximum and minimum temperature The settings range is from 0 2 C to 5 C If the floor temperature exceeds the maximum temperature the underfloor heating will be disabled It wil...

Страница 16: ...sensor differs from the actual temperature Calibration setting range is from 9 9 to 9 9 C with the accuracy of 0 1 C To calibrate the built in sensor press the MENU button until the temperature senso...

Страница 17: ...y button on the panel or click the registration button Pressing the registration button again will allow pairing Once registration has been activated in EU MW 3 it is necessary to press the registrati...

Страница 18: ...y 2xAAA 1 5V batteries Measurement error 0 5o C Operation frequency 868MHz EU 297Z v2 Temperature adjustment range 5o C 35o C Power supply 230V 10 50Hz Max power consumption 0 1W Measurement error 0 5...

Страница 19: ...the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council of 15 November 2017 amend...

Страница 20: ...TECH 20...