4.1.

 

BLOCK DIAGRAM  - MAIN MENU 

 

*These  functions  are  displayed  only  after  the  additional  sensor  has  been  connected  to  the  floor  sensor  contact  and 
activated in the controller menu by selecting ON in the Floor sensor submenu.  

4.2.

 

DAY OF THE WEEK 

After entering the main menu, all icons which are not connected with the 
parameter which is being edited are not displayed. The first parameter is 

day  of  the  week.    Press 

 or   

 until  the  current  day  of  the  week  is 

displayed.  

Press MENU to confirm and move on to the next parameter or press EXIT 
to confirm and return to the main screen view. 

Menu

 

Day of the week

Clock settings

Day from...

Night from...

Button lock

Optimum start

Automatic manual mode

Weekly program

Pre-set comfort temperature

Pre-set economical temperature

Pre-set temperature hysteresis

Temperature sensor calibration

Floor sensor

Maximum floor temperature*

Minimum floor temperature*

Floor temperature hysteresis

Service menu

Heat/Cool

Edition min. pre-set temperature

Edition max. pre-set temperature

Optimum Start calibration

Factory settings

Содержание EU-292n v3

Страница 1: ...EU 292n User manual 1 EU 292n v3...

Страница 2: ...f the week 11 4 3 Clock settings 12 4 4 Day from 12 4 5 Night from 12 4 6 Button lock 12 4 7 Optimum start 12 4 8 Automatic manual mode 13 4 9 Weekly control 13 4 10 Pre set comfort temperature 15 4 1...

Страница 3: ...es installing the device etc The device should be installed by a qualified electrician The device should not be operated by children WARNING The device may be damaged if struck by a lightning Make sur...

Страница 4: ...ables the regulator to fulfil a wide range of functions maintaining the pre set room temperature manual mode day night program weekly control underfloor heating system control optional an additional t...

Страница 5: ...n diagram The room regulator should be connected with the heating device with the use of a two core cable When connecting devices with a power greater than 1A it is necessary to use a contactor Option...

Страница 6: ...n heating mode it may also cooperate with a floor sensor In such a situation the contact remains closed when the floor temperature is below the minimum threshold After the threshold temperature has be...

Страница 7: ...rol icon appears on the main screen Manual mode In this mode the pre set temperature is adjusted manually from the main screen view with the use of these buttons Manual mode is activated automatically...

Страница 8: ...en view press this button to activate the weekly control or day night mode In the controller menu use this button to confirm the settings and return to the main screen view 3 in the main screen view p...

Страница 9: ...nu 5 Floor temperature 6 Pre set room temperature 7 Time 8 Buttery level 9 An icon informing about room cooling heating The animation differs depending on the selected operation mode Heating mode the...

Страница 10: ...S The user navigates the menu structure using EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited parameter is flashing whereas...

Страница 11: ...or until the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Menu Day of the week Clock setting...

Страница 12: ...user to define the exact time of entering the night mode When Day night mode is active economical temperature applies at nighttime To configure this parameter press MENU until Night from setting appe...

Страница 13: ...med change resulting from the previous operation mode is introduced If the function is disabled OFF the manual mode remains active regardless of the pre programmed changes 4 9 WEEKLY CONTROL This func...

Страница 14: ...the user opens up the program editing screen Each time the user holds the MENU button the program number changes When the desired number appears on the screen the user may start editing its parameters...

Страница 15: ...15 21 comfort temperature 22 23 economical temperature NOTE When the user finishes the editing process by pressing EXIT button the controller returns to the main screen view and this program is select...

Страница 16: ...lator has been used for a long time if the room temperature measured by the internal sensor differs from the actual temperature Calibration setting range is from 10 to 10 C with the accuracy of 0 1 C...

Страница 17: ...e set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C In order to set the hysteresis press MENU until the hysteresi...

Страница 18: ...confirm and go on to edit the next parameter or press EXIT to confirm and return to the main screen view Optimum start calibration Optimum start calibration starts when the controller detects the heat...

Страница 19: ...ting to electromagnetic compatibility EU OJ L 96 of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the...

Страница 20: ...TECH 20...

Отзывы: