background image

EU-292n user’s manual 

 

 

 

 

 

 

 

       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EU-292n v2 

Содержание EU-292n v2

Страница 1: ...EU 292n user s manual 1 EU 292n v2...

Страница 2: ...2 Day of the week 13 4 3 Clock settings 14 4 4 Day from 14 4 5 Night from 14 4 6 Button lock 14 4 7 Optimum start 15 4 8 Automatic manual mode 15 4 9 Weekly program 16 4 10 Pre set comfort temperature...

Страница 3: ...les installing the device etc The device should be installed by a qualified electrician The device should not be operated by children WARNING The device may be damaged if struck by a lightning Make su...

Страница 4: ...les the regulator to fulfil a wide range of functions maintaining the pre set room temperature manual mode day night program weekly control underfloor heating system control optional an additional tem...

Страница 5: ...the heating device III HOW TO INSTALL THE CONTROLLER NOTE The device should be installed by a qualified electrician The EU 292n v2 room regulator connection diagram In order to install the device prop...

Страница 6: ...TECH 6 The EU 292n v2 regulator can be used as a wall mountable panel or it can placed on any surface using a stand included in the set heating device...

Страница 7: ...eiver automatically disables the heating device after 15 minutes Registration of the EU MW 3 receiver 1 Press the registration button on the EU MW 3 receiver 2 In order to register the relays select t...

Страница 8: ...d in heating mode it may also cooperate with a floor sensor In such a situation the contact remains closed when the floor temperature is below the minimum threshold After the threshold temperature has...

Страница 9: ...trol icon appears on the main screen Manual mode In this mode the pre set temperature is adjusted manually from the main screen view with the use of these buttons Manual mode is activated automaticall...

Страница 10: ...en view press this button to activate the weekly control or day night mode In the controller menu use this button to confirm the settings and return to the main screen view 3 in the main screen view p...

Страница 11: ...enu 5 Floor temperature 6 Pre set room temperature 7 Time 8 Buttery level 9 An icon informing about room cooling heating The animation differs depending on the selected operation mode Heating mode the...

Страница 12: ...S The user navigates the menu structure using EXIT and MENU In order to edit particular parameters press MENU Next press MENU to view the controller functions the edited parameter is flashing whereas...

Страница 13: ...il the current day of the week is displayed Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view Menu Day of the week Clock settings Day...

Страница 14: ...U to confirm and move on to the next parameter or EXIT to confirm and return to the main screen view 4 5 NIGHT FROM This function enables the user to define the exact time of entering the night mode W...

Страница 15: ...e current room temperature will be close to the desired value In order to activate this function press MENU until Optimum start settings appear Use the buttons to activate deactivate the function Pres...

Страница 16: ...elected program number is set HOW TO CONFIGURE PARTICULAR WEEKLY PROGRAMS Weekly program allows the user to define the time when comfort temperature and economical temperature will apply Depending on...

Страница 17: ...ICULAR HOURS An hour which is being edited is displayed on the controller screen In order to assign comfort temperature press In order to select economical temperature press The controller automatical...

Страница 18: ...he pre set temperature tolerance in order to prevent undesired oscillation in case of small temperature fluctuation within the range of 0 2 4 C In order to set the hysteresis press MENU until the hyst...

Страница 19: ...parameter or press EXIT to confirm and return to the main screen view 4 17 MINIMUM FLOOR TEMPERATURE In order to set the minimum floor temperature enable floor heating and press MENU until the minimu...

Страница 20: ...ter or press EXIT to confirm and return to the main screen view NOTE Cooling mode mustn t be selected in the case of using a floor sensor it may lead to underfloor system damage How to edit the minimu...

Страница 21: ...temperature 5 C 50 C Maximum power consumption 1W Potential free cont nom out load 230V AC 0 5A AC1 24V DC 0 5A DC1 Operation frequency 868MHz Maximum transmitting power 25mW AC1 load category single...

Страница 22: ...ards the restriction of the use of certain hazardous substances in electrical and electronic equipment implementing provisions of Directive EU 2017 2102 of the European Parliament and of the Council o...

Страница 23: ...EU 292n user s manual 23...

Страница 24: ...TECH 24...