6
1
INTRODUCTION
The level gauges series LT are very robust equipment and resistant to extreme conditions of
temperature and pressure, as well as corrosive chemicals, depending on the manufacturing
materials used.
They can fit switches that allow to detect a specific level and provide an alarm signal to a
remote device. They can also fit a resistive sensor with a 4-20 mA transmitter proportional to
the level.
2 WORKING
PRINCIPLE
A float inside a chamber communicated with the tank whose liquid level needs to be
measured, floats on the liquid surface and moves together with it, as level increases or
decreases.
The float is designed for the specific working liquid density and shows the tank level by
means of magnetic coupling.
This is possible thanks to an external float housed in a borosilicate glass pipe (LT models)
that rises or falls depending on the height of the level in the tank, or by a magnetic strips rail
(LTL models), that mounted externally and isolated of the level gauge chamber, changes its
colour with the magnetic field.
3 MODELS
LT ... LTL106
Body in AISI 316L, flanged connection
LT ... LTL116
Body in AISI 316L, threaded connection
LT ... LTL14
Body in PVC, PVC-C, PP or PVDF, flanged connection
LT ... LTL15
Body in SS 316L with internal PTFE coating, flanged connection
Содержание LT106
Страница 1: ...R MI LT Rev 3 english version Instructions manual The art of measuring Series LT Level gauge...
Страница 41: ...41 LT LTL15 PTFE All dimensions in mm LT LTL14 PP PVC PVC C PVDF According to DN According to DN...
Страница 42: ...42 All dimensions in mm LTL APR LT APR LT AMM AMD LTL AMM AMD...
Страница 43: ...43 LT AAR All dimensions in mm LT xxx ADF LTL xxx ADF...
Страница 44: ...44 22 ATEX CERTIFICATE...
Страница 45: ...45...
Страница 46: ...46 23 ATEX DECLARATION OF CONFORMITY...
Страница 47: ...47...