Avoid  getting  any  liquid  into  the  narrow  central  cylinder  within  the  cartomizer  as  this  space 
allows for airflow (see final step if you suspect liquid has entered the central cylinder). 

 

Replace the cap. 

 

Blow  through  the  cartomizer  from  the  mouthpiece  end  to  ensure  no  liquid  remains  in  the 
central air-flow cylinder. 

Troubleshooting and FAQ 

My  iClear  produces  no  vapour  – 

ensure  full  and  proper  connectivity  between  the  battery  and  the 

cartomizer.  Detach  the  same  if  necessary  and  clean  all  visible  threading  with  dry  tissue.  Ensure  the 
battery is fully charged (if blinking, initiate a recharge). Try one or more new cartomizers to confirm if 
the issue is with the battery or try another battery.  

TIP – iClear cartomizers use a standard 510-Type connection – if in doubt, attempt to use the cartomizer 
on  another  battery  with  a  matching  connection  to  determine  possible  failure  of  the  cartomizer. 
Cartomizers have a typical average lifespan of around one week. 

My  iClear  is  leaking 

-  ensure  you  maintain  long  but  slow  draws.  Harsh  draws  may  cause  liquid  to 

become trapped in the air-flow chamber within the cartomizer which can end up being drawn back up 
the cartomizer into the mouth. Ensure when filling the cartomizer that no liquid is allowed to enter the 
central cylinder – to ensure this, prior to connecting the cartomizer to the battery, blow through it from 
the mouthpiece end onto tissue.   

My  batteries  will  not  charge  – 

check  the  charger  when  connected  to  the  power  source  without  a 

battery  connected  –  in  normal  circumstances  the  LED  should  appear  blue.  If  there  is  no  light  at  all, 
attempt to use another USB port or connect directly to the mains with a wall adaptor. If the problem 
persists, the charger may require replacing.  

If the charger illuminates as normal but upon connection of the battery remains the same blue colour – 
disconnect  the  battery  and  clean  the  magnetic  end  and  blow  into  the  charging  unit  and  reconnect. 
Should the light continue  to stay  blue on the charger, the battery may be refusing to accept a charge 
which may indicate that it has reached the end of its natural cell life and would require replacing.  

TIP  –  iClear  batteries  measure  180mAh  in  capacity  and  have  a  typical  lifespan  based  on  at  least  one 
charge  daily of around 4-8 weeks. Batteries are covered for a 28-day  period under warranty from the 
date of receipt.  Chargers have a 12-month electrical warranty. 

My iClear continues to activate after ceasing to inhale

 - if the device continues to activate (indicated by 

a continued blue light on the end of the battery after) without using it, this may suggest that liquid has 
entered the connecting threads of the battery affecting the workings of the air-flow sensor . Attempt to 
clean the battery threads with dry tissue. Avoid harsh inhalations to avoid leaking in the first instance 
and  correctly  follow  the  cartomizer  refilling  guide  –  should  the  problem  appear  irreparable  and  the 
battery is still under warranty, contact customer services.  