TC100D2 

(24 VOLT DC) 

 

Automatic Lubrication System Controller

 

 

WIRING INFORMATION

 

Refer also to the diagram of the Controller Printed Circuit Board shown on Page 5 of 5 
 

SCREW  TERMINAL  CONNECTORS:  6  x  2-way  plug 

(Part  #  MSTB  2.5/2-ST-5.08  by 

PHOENIX CONTACT) 
 

LIQUID TIGHT CABLE GLANDS: suit cables 2.9 - 6.4mm OD

 (Part # 3207 by HEYCO)

 

 
 

 

24VDC

 - Power Supply input (Internal fuse:  20 x 5mm 2Amp antisurge) 

 

 

IP1 

- Pressure switch or Cycle switch input (N/O volts-free) 

 

 

IP2

 

- Low Level or Remote Test switch input (N/O volts-free) 

 

 

FAULT

 - Fault Alarm Relay output (jumper selectable:  N/O volts-free contact,   

 

 

    switched 24VDC or 0VDC.  Resettable fuse rating:  0.5Amp) 

 

 

 

OP1

 

- Pump SSR output (switched 24VDC, 30Watts) 

 

 

OP2

 

- Valve Solenoid SSR output (switched 24VDC, 20Watts) 

 
 
SSR  =  Solid State Relay (short circuit protected) 
 

NOTES FOR SETTING TIMERS & OPTIONS (V6.0)

 

 

WARNING

 

- Power supply should be switched off and remain off during setup! 

 

(1) Setting DELAY TIME (DSW1) and PUMP ON TIME (DSW2) 

 
Circuit board printed overlay shows location of 8-way DIP switches DSW1 and DSW2. 
 
In the following tables:  '1' = switch ON (UP),'0' = switch OFF (DOWN). 
 
Switches 6, 7 & 8 are used to select TIME INCREMENT/Pulsed as follows: 
 

   Switch 

 

 

 

TIME INCREMENT 

   DSW1 

DELAY

 

TIME

   

 

  2 seconds 

   DSW1 

 

 

 

  1 minute 

   DSW1 

 

 

 

10 minutes 

   DSW1 

 

 

 

  1 hour

 

 

   DSW2 

PUMP ON

 

TIME

 

 

  1 second 

   DSW2 

 

 

 

10 seconds 

   DSW2 

 

 

 

  1 minute 

   DSW2 

 

 

 

  1 second on 1 second off 

   DSW2 

 

 

 

  1 second on 1 second off 

 

 

 

 

 

 

 

 

     X 30 (Total 1 minute)  

Setting DELAY TIME (DSW1) and PUMP ON TIME (DSW2) continued. 