background image

TEC Electronic Computing Scale

SL-9000/9000N-FFR-US/CA/QR

Owner’s Manual

Содержание TEC EO1-31001

Страница 1: ...TEC Electronic Computing Scale SL 9000 9000N FFR US CA QR Owner s Manual...

Страница 2: ......

Страница 3: ...cation Prohibited Do not plug in or unplug the power cord plug with wet hands as this may cause electric shock Do not place metal objects or water filled containers such as flower vases flower pots or...

Страница 4: ...ting normal operations When moving the machine take hold of the case and lift the machine Never hold the remote unit Do not place the machines on unstable or slanted surfaces as they may drop or fall...

Страница 5: ...OUTLINE OF OPERATION 10 1 11 PROGRAMMING PROCEDURES 11 1 11 1 PLU DATA EDIT 11 4 11 2 PLU DATA SETTING 11 5 11 3 INGREDIENT MESSAGE 11 7 11 4 NUTRITION SETTING 11 8 11 5 PLU VERIFYING LABEL 11 12 11 6...

Страница 6: ...AND PRINTING GRADE LINES 14 12 14 8 CALLING AND PRINTING LOGOS 14 13 14 9 SELECTING PRINT ITEM 14 14 14 10 DATE CHANGE 14 15 14 11 BATCH PRINT MODE with 30 Items Run Assignment 14 16 14 12 VISUAL COMM...

Страница 7: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses an...

Страница 8: ...ti interval Destination Code ex US CA QR etc Keyboard Type R Remote keyboard Display Type FF Fluorescent full dot display Stranded Wire Owner s Manual EO1 31001 Print Head Cleaner 24089500013 Sealing...

Страница 9: ...120 V 10 60 Hz US CA type AC 220 V 10 50 60 Hz QR type US CA 66 W 1 1 A Standby 26 W 0 39 A QR 70 W 0 66 A Standby 32 W 0 26 A 32 F 104 F 0 40 35 85 No condensation 256 x 64 dots Fluorescent display...

Страница 10: ...s board is used to expand the PLU memory to 4MB by installing the memory module See Note 1 OP 9000 RAM 512KB DIP type PS RAM to be installed on the MEMO PC board OP 9000 PIGGYBACK for memory expansion...

Страница 11: ...le Legs Main Power Switch Drawer I F LON I F CMT PL 3 I F Speed Keyboard and Programming Keyboard Display Operation Keyboard RS 232C I F MALE TMCC I F MALE RS 232C I F FEMALE Power Cord Label Guide La...

Страница 12: ...b 0 005 lb 15 30 lb 0 01 lb SL 9000N CAPACITY SCROLLING MESSAGE INDICATES SCALE AT ZERO CAPACITY CAPACIT SL 9000N WEIGHT e d WEIGHT e d 0 6 Kg 0 002 Kg 0 15 lbs 0 005 lbs 6 15 Kg 0 005 Kg 15 30 lbs 0...

Страница 13: ...V B N M SPACE ZERO FEED Name of Key Function 1 Clears numeric data just entered 2 Releases the scale from the error mode Selects the upper case or lower case Calls the PLU which follows the PLU curren...

Страница 14: ...4 lb Inserts a blank space in descriptors Stores ingredient data in the temporary memory Calls ingredient data from the temporary memory Sets the preceding item when setting PLU and nutrition informa...

Страница 15: ...mode Subtracts tare Calls a PLU or clears displayed PLU 1 2 3 4 5 6 7 8 9 1 10 11 12 13 14 15 16 17 18 2 19 20 21 22 23 24 25 26 27 PRESET COUNT 28 29 30 31 32 33 34 35 36 GRADE LINE 37 38 39 40 41 42...

Страница 16: ...key page 2 Selects the function for change Print OFF Returns to the main menu Accesses print item auto message timer print format and issue mode selection mode Turns the display on off when the scale...

Страница 17: ...label Issues a test label Adjusts the zero point Changes the label issue mode between Automatic issue and manual issue Optional key by initial setting to Calls the PLU frequently used 5 3 SELF SERVICE...

Страница 18: ...urity Speed key can operate among unit price change prog mod read reset mode security mode Of course panel key can operate those panel key don t indicate top of key sheet NOTE If you would like to swi...

Страница 19: ...7 Connect a PC AT Keyboard if necessary 8 Turn the power on and then press the power key See page 10 1 9 Set the following program menu Menu Page ITEM No Programming Name 2 0 PRINT FORMAT 2 1 DATE TIM...

Страница 20: ...ctors into the scale unit 4 Secure the remote blind plate using the two screws B 4x8 5 Attach the meat platter NOTE Care must be taken when handling the remote unit because of the display tube and PC...

Страница 21: ...urface Level the scale by turning the adjustable legs so that the air bubble is inside the center circle 2 Adjustment Procedure When the air bubble moves toward the left side turn the right adjustable...

Страница 22: ...nd backing paper stopper then remove the receipt label core with the backing paper You can loosen the backing paper by turing the paper winding shaft anti clockwise 3 Put a new receipt label roll over...

Страница 23: ...and receipts should be left aligned as viewed from the front of the machine and always threaded in parallel with the media shaft and the print head Failure to do this may cause a paper jam or a skew...

Страница 24: ...Refer to respective sections for explanation of each menu enclosed by a double rectangle 4 In the self service scale mode the initial setting 13 2 is set to 1 the POWER and ESC Keys are available in t...

Страница 25: ...o x o x 14 TEST PRINT o o o x 15 MANUAL ISSUE WITH WEIGHING o x o x 16 VOID REGISTRATION o o o x 17 AUTO ISSUE WITH WEIGHING o x o x 18 1 2 1 4LB KEY o x x x 19 100g kg KEY o x x x 20 LB kg KEY o x x...

Страница 26: ...an access refer to Section 13 2 and enter the password 2 In Section 11 1 11 2 and 11 3 items which have been sold on that day cannot be called before resetting refer to Section 15 unless Initial Set 1...

Страница 27: ...PLU TO SPECIFIC SPEED KEY 11 17 11 PRT LOCATION 2 0 SELECT LABEL FORMAT AND ADJUST 11 18 12 DATE TIME SETTING 2 1 PROGRAM DATE TIME MACHINE STORE CODE 11 20 13 CMT PL 3 2 2 BACK UP LOAD DATA OF PLU IN...

Страница 28: ...ve the cursor to the preceding line press key or key when entering a commodity name 5 Pressing the key toggles between capitals and small letter 6 When entering a commodity name press or key instead o...

Страница 29: ...tempt to call a PLU that has not been stored in the PLU file results in an error 2 Under this Menu Menu No 0 open price PLU s price cannot be changed 3 In the self service scale mode the initial setti...

Страница 30: ...7 8 1 0 Enter PERIOD OF RELISH Max 3 dig ENTER Is status of initial set 8 1 2 0 or 1 Select compulsory tare Is status of initial set 23 1 1 0 Enter tare wignt Max 2lb US Max 1 kg 2 205 lb CA ENTER Is...

Страница 31: ...e a multiple of 5 up to 2 000 lb for US type and a multiple of 2 up to 1 000 Kg for CA QR type 6 Safe handling instructions can be printed on 57 mm wide labels only Safe handling instructions are prin...

Страница 32: ...ccurs 3 Once you exit this menu and enter again data stored in the work buffer is cleared 4 When there is no area to store ingredient data a MEMORY FULL error occurs 5 Different PLUs cannot use same t...

Страница 33: ...Container Enter the Calories 0 9999 Enter the Calories from Fat 0 9999 Additional Information Area 1 0 9999 Enter the Total Fat 0 99999 or 0 0 999 9 Enter the Saturated Fat 0 99999 or 0 0 999 9 Enter...

Страница 34: ...ain MENU NOTES 1 When entering PLU be careful of the following When a selected PLU is not stored in the PLU file an error occurs 2 Nutrition file is input each time the key is pressed Thus the if you...

Страница 35: ...intake of Calories Necessary daily intake of Calories No 2 Percentage of necessary daily intake of Total Fat Necessary daily intake of Total Fat No 3 Percentage of necessary daily intake of Saturated...

Страница 36: ...ory file is sorted when a memory full error occurs d Enter the PLU max 6 dig e DELETE PLU ENTER d Not Sorting Sorting e Any key except Y Y Area for titles Area for entry data Set in this menu Nutritio...

Страница 37: ...e key releases the scale from the error mode and returns to the initial status of this menu 4 After clearing a paper jam error the scale will wait for an entry of PLU again ENTER g 4 g MENU Page 1 1 0...

Страница 38: ...limits using the procedure below Address 32 characters 2 lines Message 90 characters Receipt Header 24 characters in the 1st 2nd line and 48 characters in the 3rd line NOTE When the fixed message is s...

Страница 39: ...rom 00 to 99 seconds When 00 is entered no message will be displayed 3rd message 01 to 08 represents messeages No 1 to 8 11 to 23 represents logo No 01 to 13 2nd message 01 to 08 represents message No...

Страница 40: ...ogo must be a single logo and a fixed display When logos are combined no message will be displayed 3 combination of message and logo It is prohibited When both a message and logo are combined together...

Страница 41: ...net weight data is printed 11 9 GRADE LINE Menu Page 1 Item No 8 You can set the maximum 49 kinds of grade lines max 32 characters line and call one of them to print it on the label NOTES 1 Print posi...

Страница 42: ...al number ranging from o to 99 Entering a 0 clears a Dept No Vendor Number Vendor numbers can be be set when the Initial Setting 11 1 is set to 1 Vendor numbers are assigned to the speed keys in two w...

Страница 43: ...ts 1 gradation 0 462 mm 3 dots Only when using the bar code change label with pre feed area This adjustment cannot be made on the Variable Length Label When Batch Printing with backing paper is select...

Страница 44: ...90 5 No No No 33 83 18 2 48 mm 4 57 mm Yes 104 8 No No Yes 123 8 No No 34 84 22 2 48 mm lines only Yes 112 7 No No No 35 85 38 4 57 mm lines only No Yes 171 4 No No 36 86 BOTTOM BARCODE 22 38 2 48 mm...

Страница 45: ...the store No max 5 dig NOTES 1 Express the time in a 24 hour military format 2 The SL 9000 will check details of date time input and any wrong date time will result in an error mode Then the correct...

Страница 46: ...the SL 9000 4800 BPS or 2400 BPS by using the rotary switch Press the key of the PL 3 then check whether the SAVE LED is on Program the file number of the data disc by using the rotary switch File No...

Страница 47: ...FROM CMT 9 READ ING IN NEW FORMAT 10 WRITE NUTRI TO CMT 10 SAVE NUTRITION IN NEW FORMAT 11 VERIFY NUTRI CMT 11 COMPARE NUTRITION IN NEW FORMAT 12 READ NUTRI FM CMT 12 READ NUTRITION IN NEW FORMAT 13 W...

Страница 48: ...urn the power switch OFF and ON again 3 This setting is not available in case that the Initial set 13 6 is set to 1 LAN allowed g Table 5 Transmission Delay Time Table TR Time ms TR Time ms 1 20 39 6...

Страница 49: ...Setting numbers other than the above results in an error 4 MENU Page 2 PROG ESC MENU Page 2 Main MENU Yes IN LINE OFF LINE ENTER m ID Set the number of scales in the system ENTER DLL n ID 1 p m No CHA...

Страница 50: ...following two ways It is selectable by the Initial Settings 0 6 and 0 7 1 LOCK SCALE method Step 1 LOCK SCALE is sent 1 Step 2 Selected data is sent 2 Step 3 OPEN SCALE is sent 1 If an error occurs d...

Страница 51: ...C D 0 2 C2 C3 C4 C5 C6 PC D P1 P2 P3 P4 C D 0 2 C2 C3 C4 C5 C6 PC D P1 P2 P3 P4 C D 0 0 0 C2 C3 C4 C5 0 0 0 0 C6 C D 0 2 0 0 0 0 PC D P1 P2 P3 P4 P5 C D Current format Flag UPC Price Total check digit...

Страница 52: ...nning from W1 W1 to W5 3 The usable keys to set the column are as follows ENTER 4 Digits and display of PLU 5 Digits and display of UPC 6 Digits and display of price 7 Display of weight Digits 8 Setti...

Страница 53: ...sume Before starting this operation set the initial setting 7 3 to 1 NOTE Title No and format of the additional information area Item Title No Format Additional 1 221 Additional 2 231 Additional 3 232...

Страница 54: ...o sizes of logos are printed differently as follows 8 MENU Page 2 PROG ESC MENU Page 2 Main MENU Load the tape into the CMT Loader Select a transmission item 1 SAVE SL 9000 CMT 2 VERIFY SL 9000 CMT 3...

Страница 55: ...e idiom number must be set from 1 to 50 in order One idiom can contain a maximum of 20 characters Error position Error message Cause Header text Data text Timeout Incorrect segment Incorrect logo size...

Страница 56: ...ng procedure The vendor number must be set from 0 to 39 in order One vendor name can contain a maximum of 12 characters Deleting a vendor number 0 MENU Page 3 MENU Page 3 Main MENU ENTER PROG ESC Set...

Страница 57: ...r of a label as the origin When a print item is located beyond the label width an error will occur Key functions Moves downward Data is stored Moves downward Data is stored Moves upward Data is stored...

Страница 58: ...age lines 0 38 lines 5 Bar code height 0 39 mm 4 Each print item should be printed in the following range Print area size Normal Rotation No Print Item X Y X Y Note 1 Commodity name 4 line 384 94 94 4...

Страница 59: ...ill occur in the following cases 1 Entered X point Print size X 384 dots 2 Entered Y point Print size Y 1300 dots Magnified print items become double in size 5 The following items cannot be rotated 1...

Страница 60: ...te 1 Addresses are printed together with the previous label s data To print addresses use normal labels POS Format 10 16 10 0 mm NET Format 21 26 10 0 mm Bar code Format 31 35 8 5 mm 2 Free format are...

Страница 61: ...h is framed in black in the figure on page 5 3 but not on the programming keyboard How to access REPORT menu Press the key to access th following display Enter 5 and the scale will enter the REPORT me...

Страница 62: ...e commodity name preset on each speed key is listed 53 Commodity and ingredient description report All the presets commodity names and ingredient messages are listed in the PLU order from small to lar...

Страница 63: ...EG 6 RESET 2 MARK DOWN 7 3 REWRAP 8 4 SECURITY 9 4 0 2 3 4 6 0 0 0 1 0 4 w Enter password A as 4 digits Exclude menus for which password A cannot access Protected Accessible with a password entry Unpr...

Страница 64: ...ess Valid Invalid Not need 1 2 3 4 2 6 w NOTES 1 Select validity of the password by pressing the key 2 When the same password is entered for password A and B password A has priority over the password...

Страница 65: ...stead and you can access only security menu Menu MAIN 0 PROG 5 READ 1 REG 6 RESET 2 MARK DOWN 7 3 REWRAP 8 4 SECURITY 9 Enter a menu No Accessible with the password REG Not protect menu Enter the 4 di...

Страница 66: ...h an unrated power source inaccurate scaling or other errors may occur 6 If the zero point has shifted during scaling and no tare is displayed adjust the zero point by depressing the key 7 Check the d...

Страница 67: ...is obtained by multiplying by 2 or 4 when pressing the key or key the unit price will be 0 4 key is available only when the scale is a kg scale or operated on kg base 5 When the or key is pressed the...

Страница 68: ...he commodity looked up from the PLU file will be printed as the Total Price regardless of its actual weight and the weight is also printed on the label Menu REG M DOWN or REWRAP Mode FIX Example In th...

Страница 69: ...case of purchasing 10 DONUTS for 1 50 of price for 4 DONUTS When a price of 1 50 4 DONUTS is set for PLU 33 Enter the PLU AUTO MANUAL The label is issued in succession after peeling it Single label is...

Страница 70: ...ce item can be sold as below 1 piece at 15 dollars 15 pieces at 10 dollars 15 pieces sold at 0 5 dollars per 10 pieces Enter the PLU 5 1 PLU 1 5 FOR Press Press ex 1 0 FOR 5 0 ex ex 1 5 PRT Press Ente...

Страница 71: ...attached On demand issue means to print label one by one 2 To check the remaining number clear the PLU and press the key Place a commodity on the platter Ex 0 700 lb The label is issued with the backi...

Страница 72: ...the PLU data MANUAL AUTO Batch On demand FIX Remove the commodity from the platter Repeat until the specified number of labels are issued alternating the commodity placed on the platter When the last...

Страница 73: ...count 1 1 1 1 1 1 1 2 Select basic data and nutrition information labels or a nutrition information label by pressing this key Set the number of labels Max 99 labels The nutrition information label is...

Страница 74: ...ht of this commodity is 19 oz and decides to sell it at 2 00 Enter the PLU Press Enter the new weight unit of weight oz displayed in the incremental display method i e the data is shifted to the left...

Страница 75: ...an error 6 Unit price calculation system Step 1 Weight data is calculated from royal lb into decimal lb Round off the data to two decimal places ex 21 oz 1 3125 lb round 1 31 lb Step 2 Price is divide...

Страница 76: ...00N The speed key 70 will function as the key Refer to page 5 3 Set a tare within the range from 0 0 to 99 9 4 When a commodity is placed on the platter and the calculated tare exceeds the maximum a T...

Страница 77: ...be selected from maximum of 49 programmed grade lines and printed on the label Menu REG M DOWN or REWRAP Mode WEIGH or FIX or BY COUNT Enter the PLU 3 1 PLU 5 The label is issued Enter the G LINE 1 to...

Страница 78: ...to 99 1 0 LOGO Start the label issue operation 0 or C Clear the entered logo PRT Press Press NOTES 1 The logo will be effective until it is changed or deleted Logo is still effective after turning pow...

Страница 79: ...Print 11 SP Info Net Wt Print Non Print 4 Weight Print Non Print 20 Auto message timer 0 99 sec 5 Unit price Print Non Print 27 Media selection Label Receipt 6 Total price Print Non Print 28 Print fo...

Страница 80: ...nitial setting 6 6 SL 9000N only 3 Setting data will not be changed by turning the power off changing the mode or calling a PLU 4 The 0 key has no function 5 Pressing the C key allows you to return to...

Страница 81: ...bel is issued Enter the number of labels to be issued max 99 REG MANU BY COUNT ITEM 01 000001 CNT 0 Press Press PRT PRT x y PRESET COUNT 3 1 NEXT PLU FOR NEXT PLU VOID or 1 0 z A Register next preset...

Страница 82: ...gnated per PLU and printed When the PLU dose not designate the LOGO the LOGO programmed before entering Batch Print Mode is printed Enter the quantity Call the Grade Line PRT LOGO x 3 0 GRADE LINE Ent...

Страница 83: ...ected pressing the key in FIX mode results in an error 2 Programmed items are reset when the power is off changing the munu PROG REG changing the mode weight by count fix batch printing has been finis...

Страница 84: ...group the upper two digits of PLU allows you to call 6 commodities which belong to the group This function is convenient when calling a commodity which PLU you do not know 1 2 Dpt 12 Proceed to basic...

Страница 85: ...he power off and then on Maximum number of registerable commodities One scale 200 commodities One vendor 99 commodities NOTES 1 Print format varies depending on the settings of the Initial Setting 11...

Страница 86: ...ial 3 6 G Line Print Position 0 Right side on bottom line of commodity name 1 Left side on bottom line of commodity name If you would like to switch the initial setting please contact your authorized...

Страница 87: ...they are printed on labels or journal paper No ITEM READ RESET JOURNAL LABEL 0 HOURLY TOTAL 1 GRAND TOTAL 2 PLU TOTAL 3 VENDOR TOTAL ESC 6 5 or Label Journal ESC Issue each Report How to access READ o...

Страница 88: ...e 2 Journal paper Issued with journal paper 3 Label with backing paper Issued sequentially in batch mode 3 If the C key is pressed during issuance the hourly report being printed will complete then th...

Страница 89: ...r is followed by an appropriate number of keys 1 0 0 FOR 1 0 7 PRT PRT PRT PRT NOTES 1 When setting the PLU zone it is not necessary to enter a beginning number which is smaller than an end number 2 W...

Страница 90: ...f characters Press the key and re input the right data PRT FAILURE DETECTED Printer trouble 1 Check that the label and print head are set correctly 2 If the label home position is misaligned press the...

Страница 91: ...the memory is full before designated number of media are printed in Batch mode Press the key then the key and select RESET Then sum up the exceeded memory PLU DATA ERROR Error in the PLU data Press th...

Страница 92: ...r or backup master scale ON Connect them with each other or turn the scale in line 2 Call your authorized service representative SEQUENCE ERROR The power was not turned OFF and ON again after setting...

Страница 93: ...removing the label cutter reattach it using the following procedure 1 Install an unloaded label cassette on the scale 2 Install the label cutter aligning the cutter notches with the screw holes 3 Secu...

Страница 94: ...unstable Is anything touching the platter If so remove it Is the machine in a windy location Avoid locations subject to the wind No print 1 Check that the media is loaded correctly 2 Check whether the...

Страница 95: ......

Страница 96: ...PRINTED IN SINGAPORE EO1 31001G E...

Отзывы: