 CLEAN THE FIRE POT EVERYDAY.  

 AT THE END OF THE WINTER, GENERAL MAINTENANCE AND CLEANING MUST BE 

CARIED OUT AND THE FUEL STORAGE MUST BE EMPTIED. 

 

 DAMAGES CAUSED BY USING INAPPROPRIATE PELLET AND NON-REGULAR 

CLEANING ARE NOT COVERED BY WARRANTY. 

 

 SMOKE AND SMELL IS NORMAL AT FIRST USING. JUST VENTILATE THE ROOM. 

 

 DO NOT TOUCH PAINTED PARTS DURING OPERATION TO AVOID DAMAGING ON 

PAINT. 

 

THE  PROBLEMS  CAN  BE  OCCURED  IN  CASE  WRONG/LOW  QUALITY  PELLET 

USING AND CLEANING IS NOT MADE, ARE NOT COVERED BY THE WARRANTY. 

4. INSTALLATION AND CONNECTION 

4.1 GENERAL 

All the inspections for the pellet stove are done according to the stipulated standards. It 

complies with the prescribed parameters related to combustion efficiency and flue gas 

emissions. The product mentioned in this manual has been tested by the approved bodies 

according to EN 14785 Standard. 
The packaging of the stove protects the product from damage in the best possible way. 
However, the stove or its accessories may still be damaged during transport. Therefore, 

after removing the stove from the package, check whether it is complete and undamaged. 

In case of any damage, notify your dealer. If  dealer or manufacturer are not informed 

about  the  damage  and  not  presented  the  proof,  the  damages  are  not  covered  by  the 

warranty. 

 

4.2 SAFETY 

* Product must be installed by an authorized person. 

* Before installing the product, it should be determined whether the bearing capacity of 

the floor to be installed is durable to the product. In case of insufficient bearing capacity, 

appropriate measures should be taken. If the floor where the stove is to be installed is 

flammable or heat-sensitive, you should place a base (eg marble or glass base). 

 

* Care must be taken to ensure that the ventilation conditions of the place where the 

product is installed. 

*  The  pellet  stove  can  operate  in  conjunction  with  the  existing  multiple  chimneys.  In 

addition, the stove should not be connected at places such as the aspirator chimney and 

ventilator.  

* Chimney must be cleaned at least twice a year. 

* Product needs to be connected to the chimney with a shortest distance.   

Содержание TP-05

Страница 1: ...Installation and User Manual Model TP 05 TP 06 TP 07 TP 08 TP 09 TP 10 TP 11 Pellet Stove Tested according to DIN EN 14785 E N...

Страница 2: ...5 2 MENU FUNCTIONS 13 5 2 1 COMBUSTION FUNCTIONS MENU 13 Level 13 Auger Calibration 13 Fan Calibration 13 5 2 2 HEATING MANAGEMENT 13 5 2 4 CHRONO MENU 14 5 2 5 LOADING MENU 15 5 2 6 TIME AND DATE MEN...

Страница 3: ...tallation and instructions as described in the guide We recommend you to keep this guide in order to reach the information about the correct use of the stove at the beginning of every winter 2 FEATURE...

Страница 4: ...tove or its accessories may still be damaged during transport Therefore after removing the stove from the package check whether it is complete and undamaged In case of any damage notify your dealer If...

Страница 5: ...ng to the interior spaces and give heat to the environment they should not be installed in places such as bathrooms shelter cellar And they should not be used for cooking 4 3 ELECTRICITY The electrici...

Страница 6: ...chimney should be at least 80 cm higher than the highest point of the roof Use rain cap or wind cowl at the end of the chimney to avoid to come inside anything bird etc Distance between raincap and ch...

Страница 7: ...ROOM THERMOSTAT CONNECTION POINT TP 05 TP 06 TP 07...

Страница 8: ...TP 08 TP 09...

Страница 9: ...TP 10 TP 11...

Страница 10: ...the chimney provider Minimum distances to be observed in flammable or heat sensitive materials eg furniture wallpaper wood panels see diagram above are This distance can be reduced to 40 cm when the p...

Страница 11: ...to access the menus P3 SUBMENU ENTRY Use the P3 to enter a submenu in the current menu SAVE Use the P3 to save data or values in the current submenu MENU CHANGE Use the P4 and P6 s to switch between...

Страница 12: ...e chimney and second ash tray is clean Er03 Chimney outlet temperature drop or auger failure Check if there is fuel in the combustion chamber and whether the fuel is supplied by the coil Er05 Chimney...

Страница 13: ...n and Fan Calibration menus Level In this menu the pellet combustion speed can be changed with the help of P4 and P6 buttons Ex 1 2 3 4 5 6 A A Auto Use P3 to save Auger Calibration Enter the pellet l...

Страница 14: ...in the table below should be followed 3 time slot opening and 3 time slot shutdowns can be programmed for each day To set each time slot use the P3 menu button to flash the time slot on the display a...

Страница 15: ...numbers will flash Use P4 and P6 to change numbers After setting save it with P3 After the time setting is completed P4 button changes to day month year Press P3 to enter The display will flash Use P4...

Страница 16: ...6 CLEANING AND MAINTENANCE TP 05 TP 06 TP 07 TP 08...

Страница 17: ...TP 09 TP 10...

Страница 18: ...NG For the cleaning of the flame transmission channels the combustion wall behind the firepot should be removed by taking screws out Clean the flame channels and put the part where its place 6 2 COMBU...

Страница 19: ...continue to serve you in the necessary conditions You are kindly requested to inform the relevant dealer where you have purchased the product from with the model number printed on the label on the bac...

Страница 20: ...anayi B lgesi 8 Cad No 16 Melikgazi KAYSER Tel 90 0 352 321 28 11 Fax 90 0 352 321 28 14 E posta aral aralmakina com tr Sign Stamp Company Name Address Tel Fax E posta Sign Stamp User Informations Nam...

Отзывы: