5.6.11 Expert menu (TIG)
To change the advanced setting parameters, hold down the "Welding parameters" button for
2 seconds after selecting the welding process.
The following diagram shows the setting options.
ENTER
EXIT
NAVIGATION
2s
2s
Figure 5-14
Display
Setting/selection
Switch ignition mode
HF ignition
Liftarc
Gas pre-flow time
Setting range: 0.0 s to 5.0 s (0.1 s increments)
Ignition current
Setting: 1% to 200% of main current AMP (depending on main current)
Upslope time to main current
Setting: 0.0 sec. to 20.0 sec. (factory setting 1.0 sec.)
End-crater current
Setting range in percent: 1 % to 200 % depending on main current
Pulse current
Setting range 1% to 200%
Pulse balance
Percentage of time from pulse cycle Tpuls for pulse current