Strain gauge load cell Instructions for Use

TU-NR-C-G

Tension/Compression Load Cell

Introduction

Thank you for purchasing the TU-NR-C-G load cell.
Please read this document completely before using this 
load cell to achieve its best performance and ensure safe 
and proper operation.

 

o

Company names and product names in this document are the 
trademarks or registered trademarks of their respective owners.

Included accessories

If anything is missing or damaged, contact the retailer 
where you purchased the product.

Test report × 1
Instructions for Use (this document) × 1

IMPORTANT SAFETY INSTRUCTIONS

V

WARNING

If something abnormal occurs

Request repair from the retailer where you purchased 
the product.

Do not open the cover.

Never remove the cover from this unit. Doing so could 
cause malfunction. Request inspection and repair from the 

retailer where you purchased the product. Do not alter this 
unit. Doing so could cause malfunction.

Do not put foreign objects or water, for example, 
into the unit.

Do not place a container that holds water, for example, on 
top of this unit. If liquid is spilled, for example, and enters 
the unit, this could cause malfunction.

Do not use the unit with any power supply voltage 
other than that specified.

Do not use the unit with any power supply voltage other 
than that specified. Doing so could cause malfunction.

V

CAUTION

Unsuitable installation locations

Do not place the unit in the following types of locations. 
Doing so could cause malfunction.

 

o

Locations where it might be exposed to smoke or steam, 
such as near a kitchen table or humidifier

 

o

Unstable locations, including unsteady stands and 
tilted places

 

o

Locations that are very humid or dusty

 

o

Locations that are exposed to direct sunlight

When not using the unit for a long time

For safety, cut the power supply when not using this unit 
for a long time.

Do not operate a damaged unit.

Precautions for use

 

o

This unit is not built to be water or splash resistant, 
and it cannot be used in conditions when the relative 
humidity is high. Moreover, use in atmospheres with 
corrosive gases should be avoided.

 

o

Be careful to prevent water, oil and other substances 
from getting on the unit.

 

o

Avoid use in conditions where condensation could occur.

 

o

Connect cores to the load cell after discharging (elim-
inating) static electricity from your body.

 

o

If the surrounding temperature changes suddenly, the 
values output by this device could become unstable, 
making accurate measurement impossible.
(This could occur, for example, in a location blown by 
warm or cold air.)

 

o

Conduct load calibrations periodically.

Installation procedures

 

o

Install this unit in a place where the structure is level 
and can sufficiently bear the load being used. Output 
precision could be affected if the attachment surface 
does not meet parallelism and flatness requirements.

 

o

Refer to Figure 1 for use with only compression loads. 
Refer to Figure 2 for use with tension/compression loads.

 

o

Attach a load button when using with compression. 
When using with tension, attach a load rod, for example.

Load button

Load 

direction

Load 

direction

Load rod

Always ensure a gap

Figure 1. Compression 

Figure 2. Compression/   

 tension

 

o

Insert screws (steel hexagon socket head cap 
screws) into the screw holes near the edge of the 
load cell, and fix it to the flat attachment surface.  
(Output precision could be affected if the attachment 
surface is not flat.) The size of the screws used and their 
number depends on the rated capacity (model name) 
of the load cell as shown below.

Screw types and tightening torques

Rated 

capacity

Center screw section

Flange bolt section

Tightening 

torque

Dimension 
of load cell 
screw hole

Tightening 

torque

Dimension 
of load cell 
screw hole

1 kN

96 N·m M12 × 1

10 N·m

M6

2 kN

96 N·m M12 × 1

10 N·m

M6

5 kN

96 N·m M12 × 1

10 N·m

M6

10 kN

96 N·m M12 × 1

10 N·m

M6

20 kN

96 N·m M12 × 1

10 N·m

M6

50 kN

400 N·m M20 × 1.5

25 N·m

M8

100 kN

1.3 kN·m M32 × 2

43 N·m

M10

200 kN

3.2 kN·m M40 × 2

190 N·m

M16

Use screws with a strength grade of 12.9.
In addition, the length of thread engagement for the screw 
and the mounting part (internal threads) should be about 
twice the nominal diameter of the screw.
Please consult with us if you are uncertain about screw 
selection, for example.

 

o

Tighten with the torque shown in the “Screw types and 
tightening torques” table to prevent the load button 
or load rod from becoming loose. Be sure not to apply 
torque that exceeds the tightening torque shown 
in the table even when removing an attached load 
button or load rod.
A thread-locking fluid can be used on the screw, but 
be aware that this could prevent removal of the load 
button or load rod.

 

o

When connecting a load button or load rod to this unit 
(or disconnecting one), check the values in the Values 
Table of the Specifications.

 

o

When using with tension, consider the detent of all the 
screws, and consider implementing inspections before 
starting work, for example.
In addition, also consider examinations to prevent 
accidents caused by falling objects due to damaged 
load cells resulting from overloads and unbalanced 
loads, for example.

Precautions when placing loads on the unit

 

o

Make sure the load is perpendicular to the surface to 
which this unit is attached.

 

o

Apply the load so that it is centered on the center of 
the unit. If the load is not centered (eccentric load), 
twisting, for example, and measurement errors could 
occur. This could even result in damage.

F1

F2

F

F is the correct load orientation
F1 is an eccentric inclined load
F2 is an eccentric load

 

o

If the load receiving area is contacted by something that 
is at a different temperature and the load is increased, 
the values output by this device could become unstable, 
making accurate measurement impossible. In such a 
case, wait until the temperature difference ceases to 
exist before measuring.

 

o

Do not apply any load to the area shown by shading 
with diagonal lines in the illustration below. Applying a 
load to the shaded area will break the load cell.

Electrical connection of load cell

Connect as shown in the illustration below. Incorrect con-
nections could result in inability to balance and in errors 
occurring in the output voltage when loads are applied.

Receptacle in device

A

B

C

D

E

NDIS-compliant receptacle

 

o

This unit does not support remote sense.
See the operation manuals of indicators and strain 
amps that support remote sense for how to connect 
sensors with those units.

 

o

The shield is connected to the main body of this prod-
uct. For this reason, if grounding is necessary because 
of external noise or another issue, arrange to ground 
the shield to a part other than the body of this unit, 
for example.

 

o

Use a specialized cable when replacing the cable or to 
increase the length. (Please consult with us.)