3-3. Connecting to power input terminals, FG
terminal, and protective ground terminal
Check the power supply and determine that the type of the
power supply you have received conforms to the specifications
that were provided at the time of order placement, and then
connect the AC or DC power supply.
3-3-1. AC power supply
The AC power input voltage is 100–240 V AC.
For power supply connection, use power wires that are 0.326
to 2.081 mm
2
in cross-sectional area (22 to 14 AWG).
Connect those wires to the terminal block by using crimp
connectors (for M3, 6 mm or less in width).
For grounding, use a ground wire (green/yellow) that is 3.309
mm
2
in cross-sectional area (12 AWG).
Connect the wire to the protective ground terminal by using a
crimp connector (for M4).
White
Black
Green/yellow
Pro
tec
tive
gro
und
wir
e
(Gre
en/
yell
ow
)
<
Power cord wire colors (for the provided AC power cord)
L: Black
N: White
FG: Green/yellow
<
The provided AC power cord is only intended for use within
Japan, rated for 10 A at 125 V AC. If you want to use the
TD-260T at a voltage exceeding the specified voltage or
overseas, be sure to use another AC power cord that is more
appropriate for your operating
<
The FG terminal is internally connected to the protective
ground.
<
The frequency is 50–60 Hz.
CAUTION
<
For the TD-260T to warm up, wait for more than 5 minutes
after it is turned on.
<
Be sure to install the cover over the power input terminal
block.
3-3-2. DC power supply
The DC power input voltage is 10–28 V DC.
For power supply connection, use power wires that are 0.326
to 2.081 mm
2
in cross-sectional area (22 to 14 AWG). Connect
those wires to the terminal block by using crimp connectors (for
M3, 6 mm or less in width).
For grounding, use a ground wire (green/yellow) that is 3.309
mm
2
in cross-sectional area (12 AWG).
Connect the wire to the protective ground terminal by using a
crimp connector (for M4).
+
–
FG
pro
tec
tive
gro
und
wir
e
(Gre
en/
yell
ow
)
<
The FG terminal is internally connected to the protective
ground.
<
The current draw at 12 V DC input is about 0.8 A.
CAUTION
<
If you want to use the TD-260T as a CE compliant unit, the
length of the power cord to be used for the TD-260T must
be 3 m or less.
<
For the TD-260T to warm up, wait for more than 5 minutes
after it is turned on.
<
Be sure to install the cover over the power input terminal
block.