35
ENGLISH
STANDALONE OPERATION OF CD-R-DUPLI-4
Important Hint according Standalone Operation
To avoid malfunction the CD-R-Dupli-4 can not be con-
nected to a PC while it is operated in standalone mode.
Please disconnect the SCSI cables between the copy sta-
tion and PC before the CD-R-Dupli-4 is switched on.
To
ensure errorfree operation both SCSI terminators which
were shipped with the unit have to be plugged into the
connectors on the backside of the unit.
OPERATION IN PC MODE
To operate the CD-R-Dupli-4 with a personal computer the external
SCSI terminators have to be disconnected. To operate the CD-R-Dupli-
4 the PC must be equipped with two separate SCSI controllers. The
connections between the CD-R-Dupli-4 and the PCs controller(s) are
made with two appropriete SCSI cables.The software package which
is shipped with the unit makes several additional functional features
available as for example the combining of copy contents with the PC.
Please refer to the manual of the software package for further details.
Important Hint according the PC Mode
When using the copy station in PC Mode the controls at
the CD-R-Dupli-4 are not allowed to be operated under
any circumstances.
Important
Please ensure the proper termination of the SCSI bus at the PC.
The SCSI IDs are factory preset and cannot be changed. The
upper SCSI connector makes the master drive (SCSI ID 1)
and the two CD recorders with the SCSI ID's 2 and 3 avail-
able. The lower connector serves to control the two CD re-
corders with the SCSI ID's 4 and 5.
Standalone Operation of CD-R-Dupli-4