background image

TECP-77-222 

 Issue 1 

 August 2012

300001759666 Rev A

Main Remote Access Unit

Secondary Remote Access Unit

InterReach Spectrum

 

Remote Access Unit 

Installation Guide

Содержание SPT-M1-8519-1

Страница 1: ...TECP 77 222 Issue 1 August 2012 300001759666 Rev A Main Remote Access Unit Secondary Remote Access Unit InterReach Spectrum Remote Access Unit Installation Guide ...

Страница 2: ... profits and TE further disclaims any and all liability for indirect incidental special consequential or other similar damages This disclaimer of liability applies to all products publications and services during and after the warranty period Specific Disclaimer for High Risk Activities This Product is not specifically designed manufactured tested or intended for use in high risk activities includ...

Страница 3: ...tall the RAUs and Antennas 11 Mount the RAUs and Antennas 11 General Safety Precautions 11 Connect the IFEU to the MRAU 12 Connect the MRAU to SRAUs 14 Configure the MRAUs and SRAUs 16 Appendix A Specifications 17 Remote Access Unit Specifications 17 Spectrum System Specifications 17 Composite Power Out of RAU 19 Appendix B 75 Ohm CATV Cable 20 CATV Cable Requirements 20 Belden 1695A Coax Specific...

Страница 4: ...LowerABC InterReach Spectrum User Documentation The InterReach Spectrum user documentation is intended for system administrators engineers and installers responsible for planning administering configuring and maintaining TE Connectivity InterReach Spectrum systems Table 1 lists the manuals that correspond to this InterReach Spectrum release Table 2 InterReach Spectrum User Documentation Title TECP...

Страница 5: ... developed guidelines for evaluation of human exposure to RF emissions The guidelines incorporate limits for Maximum Permissible Exposure MPE for power density of transmitter operating at frequencies between 300 kHz and 100 GHz Limits have been set for portable mobile and fixed equipment TE Connectivity products fall in the category of fixed equipment products intended to be permanently secured an...

Страница 6: ...mote Access Unit MRAU which can power up to three additional Secondary Remote Access Units SRAUs An MRAU supports two frequency bands and each SRAU can support up to two frequency bands for a total of up to eight frequency bands MRAUs and SRAUs are grouped logically based on common service provider groupings and include as an example 850 1900 700 700 MIMO 800 900 SMR 1900 AWS To add more frequency...

Страница 7: ... RF IN FWD NOT TO EXCEED 5 dBm PWR STATUS HOST x x x x x x x x x x x x x x x x x x x x x x x x x x x REMOTE SYSTEM II IF DART XXXXXXXXXX BW XX MHz FWD IF OUT REV IF IN PWR STATUS REMOTE IF DART XXXXXXXXXX BW XX MHz FWD IF OUT REV IF IN PWR STATUS REMOTE IF DART XXXXXXXXXX BW XX MHz FWD IF OUT REV IF IN PWR STATUS REMOTE IF DART XXXXXXXXXX BW XX MHz FWD IF OUT REV IF IN PWR STATUS REMOTE IF IF Stan...

Страница 8: ...REV SECONDARY PORTS 1 2 3 FWD SECONDARY PORTS 1 2 3 FWD IF IN LINK STATUS 1 2 3 6 5 4 Ref Component Device Function 1 RF SubMiniature version A SMA cable 1 50 RF SMA to SMA cable Connects two RF bands together when there is only one N type connector on the RAU For cases when there is an N type connector for each RF band 700MIMO or PCS AWS there will not be an SMA cable 2 Antenna port s 50 N type c...

Страница 9: ...Off No SRAU previously connected Green MRAU receiving communications from the IFEU Red MRAU has not received communications from the IFEU for more than 90 seconds Off During initial power up MRAU is powering up and waiting for IFEU communications Green Unit has no alarms or a Minor alarm is active Blinking Green Unit or band is set out of service Red Major alarm detected Green Downstream unit corr...

Страница 10: ... sends them to the MRAU using 75 CATV cable SRAU Ports Cable and Connectors 1 4 2 3 LINK STATUS SECONDARY REV SECONDARY FWD SECONDARY REV SECONDARY FWD LINK STATUS Ref Component Device Function 1 SECONDARY REV connector F connector port Connects to one of the MRAU REV SECONDARY ports 1 3 via CATV cable 2 RF SMA cable 1 50 RF SMA to SMA cable Connects two RF bands together when there is only one N ...

Страница 11: ...ications from the IFEU Red SRAU has not received communications from the IFEU for more than 90 seconds Off During initial power up SRAU is powering up and waiting for IFEU communications Green Unit has no alarms or a Minor alarm is active Blinking Green Unit or band is set out of service Red Major alarm detected Green SRAU is powered on correctly Yellow or Blinking Yellow There is an MRAU FWD conn...

Страница 12: ...M 2100AWS MIMO SECONDARY RAU 2 SPT S1 7070 1 MIMO SPECTRUM 700 MIMO SECONDARY RAU UpperC LowerABC 2 SPT S1 8019 22 SPECTRUM 800 Path 2 1900 Path 2 SECONDARY RAU 1 SPT S1 8090 1 SPECTRUM 800 900 SMR SECONDARY RAU 1 SPT S1 80AWS 1 SPECTRUM 800 2100AWS Path 1 SECONDARY RAU 1 SPT S1 8519 22 SPECTRUM 850 Path 2 1900 Path 2 SECONDARY RAU 1 SPT S1 AWS19 12 SPECTRUM 2100AWS Path 1 1900 Path 2 SECONDARY RA...

Страница 13: ...RAU unless it is in an approved AOC weatherproof NEMA4 housing CAUTION Attach all RAUs securely to a stationary object that is a wall pole or ceiling brackets To mount a RAU securely to a wall ceiling bracket or pole use 6 diameter fasteners in the four slotted mounting holes CAUTION Do the following to maintain proper ventilation Keep at least 76 mm 3 inch clearance around the RAU Do not stack RA...

Страница 14: ... to the same length The FWD and REV cables should be the same cable type both RG6 or both RG11 A pair of CATV cables connects each MRAU to the IFEU The IFEU REV Module IF IN port and the IFEU FWD Module IF OUT port must match For example if IFEU REV Module IF IN Port 3 is used use IFEU FWD Module IF OUT Port 3 Refer to Appendix B 75 Ohm CATV Cable on page 20 for information on maximum RG 6 or RG 1...

Страница 15: ...antenna MRAU Step 6b Step 6c KEY IFEU FWD Module IF OUT connector to MRAU FWD IF IN connector IFEU REV Module IF IN connector to MRAU REV IF OUT connector Connect the IFEU to the MRAU InterReach Spectrum Remote Access Unit Installation Guide Page 13 TECP 77 222 Issue 1 August 2012 2012 TE Connectivity Ltd ...

Страница 16: ...MRAU to SRAUs Two cables required per SRAU 8 Test the cable termination for each CATV cable before installing it 9 Connect F connector CATV cables from the MRAU to an SRAU in the order given below If the LEDs do not perform as described in this procedure refer to SRAU LEDs on page 9 a Connect a CATV cable from an MRAU FWD SECONDARY PORT 1 2 or 3 F connector to the SRAU SECONDARY FWD F connector b ...

Страница 17: ... REV SECONDARY FWD SECONDARY REV SECONDARY FWD LINK STATUS SRAU To an antenna To an antenna To an IFEU REV Module IF IN connector 1 8 To an IFEU FWD Module IF OUT connector 1 8 Step 9a Step 9b Step 9c Connect the MRAU to SRAUs InterReach Spectrum Remote Access Unit Installation Guide Page 15 TECP 77 222 Issue 1 August 2012 2012 TE Connectivity Ltd 10 Repeat Step 9 to install up to two more SRAUs a...

Страница 18: ... OUT connector 1 8 To an IFEU REV Module IF IN connector 1 8 To an antenna To an antenna To an antenna To an antenna KEY FWD REV Install the RAUs and Antennas Page 16 InterReach Spectrum Remote Access Unit Installation Guide 2012 TE Connectivity Ltd TECP 77 222 Issue 1 August 2012 Configure the MRAUs and SRAUs Refer to the InterReach Spectrum Element Management System 7 3 User Manual TECP 77 200 f...

Страница 19: ...rce 54Vdc from IFEU Spectrum System Specifications RF Specification Supported Frequency Blocks 2 per Remote Antenna Unit 1 8 per Host Unit Bandwidth 1 5 to 75 MHz non contiguous Frequency Band Supported 850 Cellular 800 iDEN 900 iDEN 1900 PCS 2100 AWS 700 Upper C Lower ABC Propagation Delay System Delay 12 microseconds Delay Management Digital Manual or Automatic Noise Figure Noise Figure For 1 Ho...

Страница 20: ...55 Gain dB 40 30 700 Upper C Bandwidth 746 756 776 786 Gain dB 40 30 700 Lower ABC Bandwidth 728 746 698 716 Gain dB 40 30 Appendix A Specifications Page 18 InterReach Spectrum Remote Access Unit Installation Guide 2012 TE Connectivity Ltd TECP 77 222 Issue 1 August 2012 Nominal Passband Gains Output Power Output P1dB Power per Band 26 dBm 850MHz Cell 26 dBm 1900MHz PCS 26 dBm 700MHz Upper C Lower...

Страница 21: ...17 5 14 0 10 0 6 5 iDEN 26 0 19 5 13 5 8 5 APCO 25 C4FM 900 SMR 935 940 896 901 17 5 14 0 10 0 6 5 iDEN 26 0 19 5 13 5 8 5 APCO 25 C4FM 1900 PCS 1930 1995 1850 1915 26 0 20 0 14 0 9 0 5 5 GSM 23 0 17 5 12 0 8 0 5 0 EDGE 18 0 15 0 12 0 9 0 6 0 CDMA 18 0 15 0 12 0 9 0 WCDMA 18 0 15 0 12 0 9 0 LTE 2100 AWS 2110 2155 1710 1755 18 0 15 0 12 0 9 0 WCDMA 18 0 15 0 12 0 9 0 LTE 700 Upper C 746 756 776 786...

Страница 22: ...t carries configuration and status information uses 75 type F connectors with captive center pins CATV Cable Requirements Belden CATV cable or equivalent is required see Figure 2 For the RG 6 cable use a Belden 1695A Coax For the RG 11 cable use a Belden 7732A Coax RG 11 Belden 1695A Coax RG 6 Belden 7732A Coax NOTE TE Connectivity requires solid copper center conductor CATV cable for proper DC vo...

Страница 23: ...18 AWG solid 0 040 inch bare copper conductor plenum foam FEP insulation Duofoil tinned copper braid shield 95 coverage Flamarrest jacket Overall Physical Characteristics Conductor One Coax 18 AWG Solid stranding Bare Copper BC conductor material 0 040 inch diameter Insulation Teflon Foam Fluorinated Ethylene Propylene FFEP 0 170 inch diameter Outer Shield Layer 1 Duofoil Tape Aluminum Foil Polyes...

Страница 24: ...0 pF ft Velocity of Propagation 82 Delay 1 240 ns ft Conductor DC Resistance 6 400 20 C 1000 ft Outer Shield DC Resistance 2 800 20 C 1000 ft Attenuation Freq MHz Attenuation dB 100 ft 1 000 0 240 3 580 0 450 5 000 0 550 7 000 0 650 10 000 0 750 67 500 1 740 71 500 1 780 88 500 1 940 100 000 2 100 135 000 2 400 143 000 2 500 180 000 2 800 270 000 3 400 360 000 4 000 540 000 5 200 720 000 6 100 750...

Страница 25: ...nned copper braid shield 95 coverage fluorocopolymer jacket Overall Physical Characteristics Conductor One Coax 18 AWG Solid stranding Bare Copper BC conductor material 0 064 inch diameter Insulation Teflon Foam Fluorinated Ethylene Propylene FFEP 0 274 inch diameter Outer Shield Layer 1 Duofoil Tape Aluminum Foil Polyester Tape Aluminum Foil 100 coverage Outer Shield Layer 2 Braid Tinned Copper T...

Страница 26: ...00 pF ft Velocity of Propagation 83 Delay 1 220 ns ft Conductor DC Resistance 2 500 20 C 1000 ft Outer Shield DC Resistance 1 600 20 C 1000 ft Attenuation Freq MHz Attenuation dB 100 ft 1 000 0 150 3 580 0 260 5 000 0 300 7 000 0 340 10 000 0 400 67 500 1 200 71 500 1 240 88 500 1 400 100 000 1 500 135 000 1 780 143 000 1 840 180 000 2 090 270 000 2 600 360 000 3 100 540 000 3 890 720 000 4 570 75...

Страница 27: ...gure 3 is a round radome with the following specifications 8 5 inch diameter 1 65 inch height 72 inch pigtails that are plenum rated cables with N male connectors Figure 3 Omni Antenna NOTE Two antennas per RAU is required for MIMO performance The Omni Antenna supports the following Port 1 698 806 MHz 700 Upper C Lower ABC 1710 2170 MHz AWS Port 2 806 941 MHz Cellular SMR 1850 1990 MHz PCS Port 3 ...

Страница 28: ... 32 2 712 65 42 EUROPEAN TOLL FREE NUMBERS Germany 0180 2232923 UK 0800 960236 Spain 900 983291 France 0800 914032 Italy 0800 782374 ASIA PACIFIC Sales Administration 65 6294 9948 Technical Assistance 65 6393 0739 ELSEWHERE Sales Administration 1 952 917 3000 Technical Assistance 1 952 917 3475 EMAIL ONLINE ACCESS Connectivity Products United States Connectivity Tac te com Europe Euro Tac te com A...

Страница 29: ......

Страница 30: ......

Отзывы: