Troubleshooting
b.
Under Alarms, click
C
LEAR
A
LL
D
ISCONNECTS
at the Fusion Wideband Main
Hub.
c.
Power cycle the Fusion Wideband Main Hub.
d.
RAU hardware faults. Try moving a working CATV to the suspect port and
verifying that the RAU comes up OK.
e.
Try isolating the system components:
– Check to see if the whole system is effected or a portion of the system.
– If the whole system is effected, disconnect the DAS system from the RF
source and see if the RF source is working.
– Continue to isolate by disabling portions of the system. Under System Con-
figuration, click
S
HOW
S
YSTEM
T
REE
and select a component. Then click
S
ET
O
UT
OF
S
ERVICE
/S
ET
IN
S
ERVICE
.
9.3.1.2
Fault/Warning/Status Indications
Once all of the units are powered on and the cable connections are made, the faults
from each unit can be requested using AdminBrowser. Start with the Fusion Wide-
band Main Hub and work downstream.
Resolve all faults first and then check the warnings. Take appropriate action to
resolve the faults, as indicated in the following tables. In cases where there is more
than one possible cause, they are listed from the “most likely” to the “least likely”
cause. Actions are listed in the order that they should be performed; not all actions
may need to be done.
NOTE:
If you have a red
STATUS
LED without a fault message, it probably
indicates that the unit is locked out.
Refer to Appendix C for tables containing Fault, Warning, and Status messages and
their meanings.
9.3.2
Troubleshooting Using LEDs
The following troubleshooting guide is from the perspective that all Fusion Wideband
equipment is installed, their cables are connected, and they are powered on; it is
assumed that the system was operating normally before the problem to be diagnosed
occurred.
Always use AdminBrowser, if possible, to troubleshoot the system. The Fusion Wide-
band Main Hub and Expansion Hub LEDs are for backup troubleshooting. The RAU
LEDs probably will not provide additional information for troubleshooting.
Содержание InterReach Fusion ADCP-77-044
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Wideband Installation Operation and Reference Manual D 620616 0 20 Rev F...
Страница 203: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620616 0 20 Rev F CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 210: ...A 10 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...
Страница 216: ...B 6 InterReach Fusion Wideband Installation Operation and Reference Manual CONFIDENTIAL D 620616 0 20 Rev F...