Figure 35. Adapter Pack Raised to Access Position
3. Remove the dust cap from the appropriate bulkhead adapter in the sliding adapter pack.
4. Obtain the optical patch cord (accessory) recommended for the pass-through connection.
5. Remove the ferrule dust cap from one of the patch cord connectors and then clean the
connector as specified in the Optical Fiber Connector Wet and Dry Cleaning Instructions
(ADCP-90-159) or by locally approved procedures.
6. Insert the patch cord connector into the bulkhead adapter in the sliding adapter pack.
7. Slide the adapter pack down into the closed position.
8. Route the pass-through patch cord around the radius limiters and up the guideway to the top
of the swing frame as shown in
(right swing frame) or
frame.
9. From the top of the swing frame, route the patch cord to the front guideway that leads to
the distribution panels.
10. Locate the distribution panel and the optical port to which the pass-through patch cord is
to be connected.
Warning:
Infrared radiation is invisible and can seriously damage the retina of the eye. Do not
look into the ends of any optical fiber. Do not look directly into the optical adapters or
connectors. Exposure to invisible laser radiation may result. An optical power meter should be
used to verify active fibers. A protective cap or hood MUST be immediately placed over any
radiating adapter or optical connector to avoid the potential of dangerous amounts of radiation
exposure. This practice also prevents dirt particles from entering the adapter or connector
.
Note:
Use catalog# FPCFW-SPSC-P-3.1 for UPC. Use catalog# FPCFW-APSC-P-3.1 for APC.
PULL UPWARD ON TAB
REMOVE DUST CAP
INSERT CONNECTOR
21827-A