412-10100
Rev A
38
of 74
5.5
Peak Force
The Peak Force screen provides a crimp history graph showing the tolerance limits and the peak force
recorded for each crimp. To see more points than those shown, simply touch the graph to enter a full screen
mode and use the arrow keys to move forward and backward in time.
The other graph is a histogram of the Peak Force Distribution for the entire work order. This screen is useful to
observe the process with regards to Peak Force.
Figure 34: Peak force