412-10100
Rev A
32
of 74
Figure 26: Crimp curve graph
Once you have completed all of the Learn crimps, the display will indicate Process Learned.
It is recommended to re-learn the process if something dramatically changes in the process such as changing
to a new reel of terminals or a different type of wire. It is also advisable to Re-Learn if while in production you
experience too many failures that with further inspection meet your quality requirements. Touch Re-Learn
perform the Learn process again.
Figure 27: Process learned
Based on settings that were made in CQM Settings, the Learn crimps may require the operator to touch Accept
for each Crimp.