Installation and Operating 

Instructions 

Analogue Instruments 

Panel Indicators - Challenger Series 

Products Covered 

361-**, 362-**, 363-** 364-** 

(* = additional characters) 

 

 

Scope 

This product range includes multiple functions: 

AC Ammeters and AC Voltmeters 

DC Ammeters 

DC Voltmeters 

Frequency meters 

Markings and Ratings 

Barrel side labels show function and electrical rating. The terminals are 

connected directly across the input to be measured.   

Note: that the electrical rating may differ from the dial scale marking, and 

the unit side label is definitive.   

INDOOR USE 

These meters are intended for a rated temperature range of 0 to +40°C 

and at an altitude not exceeding 2000m. 

Maximum Relative Humidity 80% for temperatures up to 31°C 

decreasing linearly to 50% Relative Humidity at 40°C 

Pollution Degree 1 or 2 

Measurement Category III 

 

Installation 

The product should be panel mounted using the mounting kit provided.  

Consideration should be given to the space required behind the unit to 

allow for bends in the connecting cables. Additional protection to the panel 

may be obtained by the use of an optional panel gasket. The terminals at 

the rear of the case should be protected from liquids.  Units should be 

mounted in a reasonably stable ambient temperature. 

  

The unit should not be mounted where it can be subjected to excessive 

direct sunlight and vibration should be kept to a minimum. Connection 

wires should be sized to comply with local regulations and should be 

terminated on to tags suitable for screw connection. The products do not 

have internal fuses,  therefore; external fuses 

must 

be used for safety 

protection under fault conditions. 

 

 

Fusing and Connections 

Connection  diagrams  should be carefully followed to ensure correct 

polarity.  Terminals are suitable for use with insulated ring lugs.  

Voltage input lines where required should be fused with a quick blow fuse 

1A maximum. Current metering circuits directly connected in line with the 

load must be fused at the rated current for the meter.  Do not fuse CT 

circuits.   

The equipment into which this meter is installed must have an adjacent 

means of isolating the supply voltage to permit safe access for subsequent 

maintenance. 

External voltage transformers (PTs) and current transformers may be 

used where appropriate to extend the range, provided that the ratings 

marked on the side label are not exceeded at point of connection to meter.  

These products are designed for permanently connected use, normal 

condition measurement category III, pollution degree 2 (e.g. non ventilated 

panels or ventilated panels with filters, without condensation occurring), 

basic insulation, for rated voltage.  

 

 

 

 

 

  

 

 

Warnings   

 

 

 During normal operation, voltages hazardous to life may 

be present at some of the terminals of this unit.

 

 

 At voltages below that specified in the Range of Use the 

meter may shut down.  However, voltages hazardous to life 

may still be present at some of the terminals of this unit.

 

 

 Installation and servicing should be performed only by 

qualified, properly trained personnel abiding by local 

regulations.

 

 

 Ensure all supplies are de-energised before attempting 

connection or other procedures.

 

 

 Terminals should not be user accessible after 

installation and external installation provisions must be 

sufficient to prevent hazards under fault conditions.

 

 

 This unit is not intended to function as part of a system 

providing the sole means of fault protection - good 

engineering practice dictates that any critical function be 

protected by at least two independent and diverse means.

 

 

 The unit does not have internal fuses therefore external 

fuses must be used for protection and safety under fault 

conditions.

 

 

 Never open-circuit the secondary winding of an 

energized current transformer.

 

 

 This product should only be operated with the CT 

secondary connections earthed.

 

 

 If this equipment is used in a manner not specified by 

the manufacturer, protection provided by the equipment may 

be impaired.

 

 

The unit is designed in accordance with BS EN 61010-1:2010 

(IEC 61010-1:2010) – Permanently connected use, Normal 

condition.  Installation category III, pollution degree 1 or 2, basic 

insulation for rated voltage.  Measurement Category III. 

EMC Installation Requirements 

 

 Whilst this unit complies with all relevant FCC and other  

(electro-magnetic compatibility) regulations, any additional 

precautions necessary to provide proper operation of this and 

adjacent equipment will be installation dependent and so the 

following can only be general guidance: 

 

 Avoid routing wiring to this unit alongside cables and 

products that are, or could be, a source of interference. 

 

 The supply to the unit should not be subject to excessive 

interference.  In some cases, a supply line filter may be required. 

 

 To protect the product against incorrect operation or 

permanent damage, surge transients must be controlled.  It is 

good EMC practice to suppress transients and surges at the 

source.  The unit has been designed to automatically recover 

from typical transients; however, in extreme circumstances it 

may be necessary to temporarily disconnect the supply for a 

period of greater than 10 seconds to restore correct operation. 

 

 Screened communication leads are recommended and may 

be required.  These and other connecting leads may require the 

fitting of RF suppression components, such as ferrite absorbers, 

line filters etc., if RF fields cause problems. 

 

 It is good practice to install sensitive electronic instruments 

that are performing critical functions in EMC enclosures that 

protect against electrical interference causing a disturbance in 

function. 

Symbols 

 

 

  

 

 

 

 

Caution 

Risk of Electric Shock 

  

  

Refer to Manual 

    

 

 

 

 

 

 

   

 

 

 

  

 

 

  

 

 

  

 

 

      

 

   

 

     

 

    

 

 

 

 

 

 

      

 

   

       

    

   

 

 

 

 

      

     

  

 

 

 

   

  

 

 

 

 

 

 

   

   

 

 

 

  

 

 

 

 

   

      

     

 

   

    

  

 

 

 

 

   

 

 

 

 

 

   

 

  

   

   

 

   

    

  

     

  

 

 

 

 

 

 

    

   

   

  

 

 

 

 

 

 

   

    

 

     

 

   

 

    

 

 

 

 

    

 

  

 

 

 

     

 

 

  

 

  

 

 

 

 

 

 

  

 

Safety

 

Caution 

Risk of Electric Shock 

  

 

It is essential that the primary current is isolated  

BEFORE connecting or disconnecting the secondary 

current connections. 

  

 

Do NOT Discard

 