Instruction Sheet
©2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
1
of 2
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at
www.te.com
408-8987
AMP NETCONNECT* HOME NET-WORKS*
Residential Cabling System (RCS)
DSL/Security Module Assembly 1479703-1
06 MAR 12 Rev A
Figure 1
1. INTRODUCTION
This instruction sheet provides the installation
procedure for the Digital Subscriber Line (DSL)/
Security Module Assembly 1479703-1 used in
AMP NETCONNECT HOME NET-WORKS media
convergence centers (MCC).
The structured cabling system is recommended to be
installed in accordance with Telecommunications
Industry Association and Electronic Industries Alliance
(TIA/EIA)-570, “Residential Telecommunications
Cabling Standard”. Refer to that publication for
technical specifications on wiring and cables.
The module assembly can be mounted into a
front-loadable 18-port panel or other panels with
openings of the same dimensions. See Figure 1.
Dimensions in this instruction sheet are in metric
units [with U.S. customary units in brackets].
Figures are not drawn to scale.
NOTE
i
Reasons for reissue of this instruction sheet are given
in Section 5, REVISION SUMMARY.
To obtain information on AMP NETCONNECT*
products, call PRODUCT INFORMATION at the
number at the bottom of this page, or visit the
AMP NETCONNECT website at
www.ampnetconnect.com.
2. DESCRIPTION
Components and features of the module assembly are
shown in Figure 1. The module assembly is supplied
with the module assembled into the plastic interface
housing. The RJ31 shorting plug and RJ14 Telco
jumper cord is supplied loose.
3. INSTALLATION PROCEDURE
1. Install the interface housing into the panel as
shown in Figure 1. To remove, press the latches
inward until they disengage from the panel.
2. Connect the telephone service cable to the
module port marked INPUT.
3. If no security panel is connected to the module
port marked RJ31X, insert the red RJ31 shorting
plug into the port marked RJ31X.
Front-Loadable Interface
Housing (Plastic)
RJ14 Telco Jumper
(2-Pair, 127 mm [5.0 in.]
RJ31 Shorting Plug
(Red)
DSL/Security Module
Front-Loadable 18-Port Panel
(Unloaded, Ref)
Latch (Each Side of Interface Housing)
Press Inward to Disengage from Panel
AMP NETCONNECT logo is a trademark of TE Connectivity.