4.2.

 

Machine Cycle with a Defective Crimp as Determined by the CQM: 

CAUTION 

When the DCCM severs a bad crimp, the operator must open the guard and remove the severed terminal. 

Failure to remove 

the severed terminal could interfere with proper application of future crimps

1.  Place the stripped wire through the opening in the guard insert, through the DCCM cutting window and 

against the wire stop of the applicator. 

2.  Press the foot switch. 

  The terminator cycles to apply a terminal to the wire. 

  The CQM analyzes the crimp and determines that it does not conform to the learned requirements. 

3.  The CQM activates the DCCM which severs the defective terminal from the wire. 

4.  Open the guard and remove the severed terminal from the crimping area. 

5.  Close the guard and clear air via the CQM screen. 

5.

 

ADJUSTMENTS 

Both the insert in the machine guard and the DCCM module are adjustable to properly align the windows in the 
guard and the DCCM with the applicator crimping area. 

Proper alignment will ensure that the wire is in the 

correct place when the machine is cycled

DANGER 

To avoid personal injury, ALWAYS disconnect electrical and air supplies before performing adjustments. 

5.1.

 

DCCM Adjustment 

The DCCM should be adjusted before adjusting the guard insert. To adjust the position of the DCCM proceed 
as follows: 

NOTE 

The applicator to be used in the machine must be installed in the machine prior to adjusting the DCCM or the machine guards. 
Install the applicator in the machine according to the instructions packaged with the applicator. 

 

Horizontal Adjustment 

1.  Install the applicator in the machine according to the instructions packaged with the applicator. 

2.  Observe the position of the DCCM cut window relative to the height of the applicator anvil. 

The bottom of the window should be in line with, or just below, the top of the anvil and centered right 
to left with respect to the anvil. 

3.  Pivot the DCCM 

unit away from the applicator by means of the unit’s detent hinge.

 

4.  Loosen the screws holding the DCCM mounting bracket to the applicator base plate until the bracket 

can move right to left. 

5.  Adjust the mounting bracket position until the DCCM cut window, when the DCCM is rotated back into 

the operating position, is centered relative to the applicator anvil. 

6.  Tighten the DCCM mounting bracket screws securely. 

 

Vertical Adjustment 

1.  With the DCCM unit in the normal operating position, loosen the screws holding the DCCM to the 

DCCM mounting bracket. 

2.  Adjust the vertical position of the DCCM unit until the bottom of the cut window is in line with or just 

below the top of the applicator anvil. 

3.  Tighten the DCCM unit screws securely. 

4.  Double-check the vertical and horizontal position of the DCCM cut window. 

If adjustments are still required, repeat necessary steps above 

 

Содержание AMP 5K/30

Страница 1: ...READ THIS FIRST 2 1 INTRODUCTION 3 2 DESCRIPTION 5 2 1 Functional Description 5 3 RECEIVING INSPECTION AND INSTALLATION 6 3 1 Receiving Inspection and Installation 6 3 2 Initial CQM Setup 6 3 3 Confi...

Страница 2: ...t Never wear loose clothing or jewelry that may catch in moving parts of the equipment Never alter modify or misuse the equipment SUPPORT CENTER CALL TOLL FREE 1 800 522 6752 CONTINENTAL UNITED STATES...

Страница 3: ...tions and requirements for the CE Terminating Machines with a DCCM installed that differ from the specifications and requirements of the standard machine are as listed below Weight 77 6 Kilograms 171...

Страница 4: ...damage NOTE Highlights special or important information Always wear approved eye protection while operating the equipment Always wear approved hearing protection while operating the equipment Use cau...

Страница 5: ...a pneumatically operated chopping blade that is mounted to the front of the terminator s base plate The DCCM cutting blade is actuated when the pneumatic solenoid connected to DCCM receives a signal...

Страница 6: ...to be performed if the Use CQM option is not seen on the CQM screen when the machine is turned on 1 In the CQM Control Panel screen select System Setting and then select DCCM Installed pick 2 Turn th...

Страница 7: ...the DCCM proceed as follows NOTE The applicator to be used in the machine must be installed in the machine prior to adjusting the DCCM or the machine guards Install the applicator in the machine acco...

Страница 8: ...n the correct position and open the main guard door 5 Tighten the two inside screws securing the guard insert then tighten the outside screw 6 Close the main guard door and double check the guard inse...

Отзывы: