3.

 

RECEIVING INSPECTION AND INSTALLATION 

3.1.

 

Receiving Inspection and Installation 

Inspect and install machine in accordance with the applicable 409 Series Customer Manual (see Figure 1). 

Air, regulated to 80-100 psi, must be supplied to the DCCM solenoid through port identified in Figure 2 Detail B. 

3.2.

 

Initial CQM Setup 

Follow these steps when the machine is being set up for the first time to ensure that the CQM is properly 
configured to operate with the DCCM. 

1.  Turn the machine and CQM on. 

2.  On the CQM screen, select the 

Use DCCM

 radio button. 

3.  Proceed with normal CQM setup as described in Section 4 of Customer Manual 409-10100. 

NOTE 

The DCCM will not operate during the learning process of the CQM. Once the learning process is complete, the DCCM will 
operate when the CQM detects a non-conforming crimp. 

3.3.

 

Configuring the CQM for use with DCCM 

NOTE 

The following steps only need to be performed if the Use CQM option is not seen on the CQM screen when the machine is 
turned on. 

1.  In the CQM Control Panel screen select System Setting and then select DCCM Installed pick. 

2.  Turn the machine and CQM off and wait approximately 10 seconds. 

3.  Turn the machine and CQM on. 

4.  On the CQM screen, select the 

Use DCCM

 radio button. 

5.  Proceed with normal CQM setup as described in Section 4 of Customer Manual 409-10100. 

4.

 

OPERATION 

NOTE 

For complete instructions on the operation of the bench terminator and applicator installation and setup, reference the 
applicable 409 Series Customer Manual (see Figure 1). 
 

NOTE 

For complete instructions on the setup and operation of the CQM, refer to Customer Manual 409-10100. 

4.1.

 

Machine Cycle with a Good Crimp as Determined by the CQM: 

1.  Place the stripped wire through the opening in the guard insert, through the DCCM cutting window and 

against the wire stop of the applicator. 

2.  Press the foot switch. 

  The terminator cycles to apply a terminal to the wire. 

  The CQM analyzes the crimp and determines that it is good. 

3.  Remove the terminated wire from the machine.    

 

Содержание AMP 5K/30

Страница 1: ...READ THIS FIRST 2 1 INTRODUCTION 3 2 DESCRIPTION 5 2 1 Functional Description 5 3 RECEIVING INSPECTION AND INSTALLATION 6 3 1 Receiving Inspection and Installation 6 3 2 Initial CQM Setup 6 3 3 Confi...

Страница 2: ...t Never wear loose clothing or jewelry that may catch in moving parts of the equipment Never alter modify or misuse the equipment SUPPORT CENTER CALL TOLL FREE 1 800 522 6752 CONTINENTAL UNITED STATES...

Страница 3: ...tions and requirements for the CE Terminating Machines with a DCCM installed that differ from the specifications and requirements of the standard machine are as listed below Weight 77 6 Kilograms 171...

Страница 4: ...damage NOTE Highlights special or important information Always wear approved eye protection while operating the equipment Always wear approved hearing protection while operating the equipment Use cau...

Страница 5: ...a pneumatically operated chopping blade that is mounted to the front of the terminator s base plate The DCCM cutting blade is actuated when the pneumatic solenoid connected to DCCM receives a signal...

Страница 6: ...to be performed if the Use CQM option is not seen on the CQM screen when the machine is turned on 1 In the CQM Control Panel screen select System Setting and then select DCCM Installed pick 2 Turn th...

Страница 7: ...the DCCM proceed as follows NOTE The applicator to be used in the machine must be installed in the machine prior to adjusting the DCCM or the machine guards Install the applicator in the machine acco...

Страница 8: ...n the correct position and open the main guard door 5 Tighten the two inside screws securing the guard insert then tighten the outside screw 6 Close the main guard door and double check the guard inse...

Отзывы: