409-32023
Rev
B
26 of 41
Figure 39
NOTE
Trigger1 dwell is the time period between receiving the Trigger1 signal (air feed from the host terminator) to when the feeder
will start its cycle. If you experience timing problems between the terminator cycle and the feeder cycle, this value may be
adjusted.
Certain terminators have different timings for the air feed signal; therefore, the Trigger1 dwell may have to be adjusted. It is
recommended to start the feeder cycle when the terminator is at its lowest position (when it is crimping the terminal). As an
example, a typical terminator cycle time around 300 msec is recommended. Therefore, a setting of 150 msec is a good
starting point.
4. In the Host mode for the precision controller, the default setting is 0 msec. This assumes that the air
feed signal on the Komax leadmaker is configured as follows (refer to Komax leadmaker
documentation for the exact process):
Direction (up or down): actuates the air feed when the terminator is going up or down.
For the precision controller, either setting is suitable.
Start of air feed from bottom-dead-center: range is 0.0 to 40 mm.
For the precision controller, use a setting of 0 mm.
Actuation time: range is 100 to 1000 ms.
For the precision controller, use a setting of 220 ms.
The settings for the Komax leadmaker integration should be set to:
HostMode = “Komax Machine”
TriggerMode = “Immediate”
TriggerDwellTime =
“0”
TriggerActiveLow = “False”
3.4.
Terminal Selection
1. Use the Up and Down navigation keys to move to the main menu bar, then use the Left or Right
navigation keys to move to the Run icon. See Figure 40.
NOTE
Pressing the Cancel key repeatedly will exit any field and return the user to the Run menu.
2. Connect the feeder to a system III applicator. Approximately 10 seconds after the connection is made,
the Run Screen icon will be displayed. The part number (PN:) and applicator serial number (SN:) will
be displayed in the Applicator box located directly below the main menu bar. See Figure 40.
Trigger1 Dwell
Small Up and Down Arrow Keys