TE Connectivity 1752786-1 Скачать руководство пользователя страница 6

408-8958 

Rev C

 

of 6

 

8.

 

TROUBLESHOOTING 

Part 

Inspection and Problem 

Possible Solution 

“C”

-Head 

Inspect for cracks, gouges, 

nicks, or galling on the “C”

-Head 

or where the “C”

-Head contacts dies 

Return tool for repair (see Section 7) 

Check to see if the upper die retaining pin does not hold the 
stationary die in place 

Return tool for repair (see Section 7) 

Check to see if the upper die release button sticks (it should 
normally move in and out easily when moderate pressure is 
applied) 

Return tool for repair (see Section 7) 

Cylinder 

Inspect for evidence of cracks, gouges, nicks, or galling 

If there are cracks, return the tool for repair (see 
Section 7) 

For traces of gouges, nicks, or galling: remove 
any sharp edges using a fine emery cloth 

Inspect for oil leaks between the cylinder and coupling 

For oil leaks and a sticky coupling, tighten or 
replace the coupling 

Check to see if the coupling sticks to the cylinder (it should 
normally turn on and off freely when moderate pressure is 
applied with a wrench) 

Quick-Disconnect 
Coupling 

The coupling mates hard or will not mate or release, or it 
leaks oil, or it sticks at the hose connection 

Replace coupling 

Ram 

Inspect the ram in the Power “ON” (ram advanced)

 position 

for evidence of galling, cracks, or oil leaks between the ram 
and the cylinder 

If there are cracks or leaks, return the tool for 
repair (see Section 7) 

If there is galling, remove any sharp edges 
using a fine emery cloth 

Check to see if the lower die retaining pin does not hold the 
moving die in place 

Return tool for repair (see Section 7) 

Check to see if the lower die release button sticks (it should 
normally move in and out easily when moderate pressure is 
applied) 

Return tool for repair (see Section 7) 

Inspect the ram in the Power “OFF” (ram retracted) position 

to ensure that the ram returns freely to its original position 

Return tool for repair (see Section 7) 

Figure 5 

9.

 

REVISION SUMMARY 

  Latest TE logo and formatting resulting in numbering changes of some paragraphs 

  Added Warning (paragraph 1) 

  Moved info on magnetic particle inspection from previous paragraph 5 to new paragraph 6.1.as a 

NOTE 

  Added Section 8 TROUBLESHOOTING and Figure 5 

Отзывы: