![TDSi EXcel4 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tdsi/excel4/excel4_user-manual_3898122010.webp)
EXcel4 Controller
Page 4
1.3
Technical specification EXcel
4
Input Voltage
100 - 240 VAC nominal ±10 %
Input Frequency
50/60 Hz
Mains Input Fuse
T3.15A 20 mm 230 v HRC
Output Voltage
13.4 to 14.2 VDC (13.8 VDC nom) on mains power
10.0 to 12.3 VDC on battery standby
Output Load Current
4A maximum
Output Ripple
150 mV
pk-pk
max
Load Output Fuse
F4.0 A 20 mm
Overload Protection
Electronic shutdown until overload/short circuit removed
Standby Battery
Capacity/Recharge Time
1 x 7 Ah Sealed Lead Acid/13 hours (to 80% capacity)
Standby Battery Charge
Current
0.5 A
Standby Battery Fuse
Protection
F1.0 A 20 mm
Storage Temperature
Range
-20 °C to +80 °C
Operating Temperature
Range
-5 °C to + 45 °C
Operating Humidity
<95 %RH, non-condensing
Case Dimensions
390 x 410 x 90 mm
Weight
5.7 kg (unpacked)
Door/Control Relay
Changeover volt-free contact 30 V, 2 A rating
TCP/IP Communications
1
Ethernet 10Base-T or 100Base-Tx (Auto-Switching), RJ45,
with indication LEDs for 10Base-T connection,
T-Base-TX connection, link and activity
Содержание EXcel4
Страница 1: ...EXcel4 Controller User Manual UM0012 Issue 8 ...
Страница 6: ......
Страница 20: ...EXcel4 Controller Page 14 Figure 6 Suppressor ...
Страница 30: ...EXcel4 Controller Page 24 Figure 13 TCP IP Connection setup ...
Страница 34: ...EXcel4 Controller Page 28 Figure 18 Communication channels ...
Страница 51: ...EXcel4 Controller Page 45 56 0V for Door Sense and Egress 57 Door 4 Egress Input 8 2 or 3 door configuration ...