Technical data
Electrical data
• Supply voltage
24 V DC
• Power consumption
max. 18 W
• Model
Integration unit with gas connection
• Overvoltage cat.
Category
I
(DIN EN 60664-1 VDE 0110-1
)
Dimensions
• Weight
370 g complete device with module, without connection lines
(178 g module carrier / 202 g driver unit)
• Dimensions
40 x 150 x 72 mm (WxHxD); without connecting lines / module
• Cable length
0.3 m
Typical application parameters (example of Standard exchange module)*
Range of applications
Precision cleaning
Adhesive bonding Compression
• Plasma temperature*
< 50 °C (at 5 mm distance)
• Distance for treatment*
2
– 10 mm
• Width for treatment*
Compressed air 5 to 29 mm; nitrogen 5 to 50 mm
• Speed*
1-15 mm/s
10-150 mm/s
100-1500 mm/s
Operating conditions
• Air humidity
< 80% rel. (non-condensing)
• Temperature
10
– 40 °C; 50 – 104 °F
• Degree of contamination 2
Storage conditions
• Air humidity
< 80% rel. (non-condensing)
• Temperature
0
– 60 °C; 32 – 140 °F
Gas connection
• Gas types
- Compressed air (purified, free of oil and lubricants)
- Nitrogen (industrial gases free of particles and oil)
- Additional gas types only after approval from
relyon plasma
.
• Gas flow rate / gas inlet
pressure
8 to 20 l/min; max. 2 bar
• Quality
Compressed air 1.4.1 acc. to ISO 8573.1
Nitrogen 2.8 (N2) acc. to DIN EN ISO 14175:N1
• Connection
Hose outer diameter Ø 4 mm (quick coupling)
*
These values are only a course guideline. Depending on treated material, process parameters,
following processes and process requirements the actual results can vary significantly from the
typical parameters in both directions (see chapter 6). Due to the low plasma temperature of
lower than 50 °C a slower treatment is not considered critically.
4
Transport/Storage
• Store the device in a dry place. This will prevent the electrical contacts from corroding.
• Protect the device from dirt and foreign objects.
• Protect the device from falls or other hard impacts.