<Page>

BEFORE USING THE PRODUCT

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before 
using this product. Incorrect usage could lead to an electrical shock, damage to the product or a fire hazard.

DANGER

Never use this product in locations where flammable gas or ignitable substances are present.

INSTALLATION WARNING

When installing, ensure that work is done in accordance with the instruction manual. When installation is improper, there is 
risk of electric shock and fire.

Installation shall be done by Service personnel with necessary and appropriate technical training and experience. There is a 
risk of electric shock and fire.

Do not cover the product with cloth or paper etc. Do not place anything flammable around. This might cause damage, 
electric shock or fire.

WARNING on USE

Do not touch this product or its internal components while circuit in operation, or shortly after shutdown. You may receive a 
burn.

While this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation.

For products with no cover, do not touch them as there are high­voltage and high temperature parts inside. Touching them 
might cause injury such as electric shock or burn.

There are cases where high voltage charge remains inside the product. Therefore, do not touch even if they are not in 
operation as you might get injured due to high voltage and high temperature. You might also get electric shock or burn.

Do not make unauthorized changes to this product nor remove the cover as you might get an electric shock or might damage 
the product. We will not be held responsible after the product has been modified, changed or dis­assembled.

Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. Please stop 
using it immediately and shut off the product. It might lead to fire and electric shock. In such cases, please contact us. Do 
not attempt repair by yourself, as it is dangerous for the user.

Do not operate and store these products in environments where condensation occurs due to moisture and humidity. It might 
lead fire and electric shock.

Do not drop or apply shock to this product. It might cause  failure. Do not operate these products mechanical stress is 
applied.

CAUTION on MOUNTING

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on.

Input line, please use the wires as short and thick as possible.

Mount this product properly in accordance with the instruction manual, mounting direction and shall be properly be 
ventilated.

Please shut down the input when connecting input and output of the product.

Please check the connector is locked securely, and be careful the harness does not come off the connector after connecting.

CAUTION on USE

Product individual notes are shown in the instruction manual. If there is any difference with common notes individual notes 
shall have priority.

Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the
product or fire due to improper use.

Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within
specifications, otherwise the product will be damaged, or cause electric shock or fire.

If the built­in fuse is blown, do not use the product even after replacing the fuse as. There is risk of abnormality inside.
Be sure to request repair to our company.

1/12

B138­04­01A

ZWS240RC Series

Instruction Manual

Содержание ZWS240RC Series

Страница 1: ...responsible after the product has been modified changed or dis assembled Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc Please stop using it immediately and shut off the product It might lead to fire and electric shock In such cases please contact us Do not attempt repair by yourself as it is dangerous for the user Do not operate and store...

Страница 2: ...field corrosive gas or conductive substances and direct sunlight or places where product is exposed to water or rain The product are PC Board Type which have surface mounted components on the solder side of PCB PCB stress such as bending twisting etc could cause damage Therefore please handle with care When handling the product hold the board edge and take care not to touch the component side When...

Страница 3: ...t terminal Neutral line Earth terminal Mounting hole hole diameter φ3 5mm These holes are connected to terminal of CN1 Must be connected to electrically conductive spacer The mounting surface of the spacer should be within Maxφ8mm Mounting hole hole diameter φ3 5mm These holes are not connected to terminal of CN1 Output terminal Output terminal V ADJ Output voltage adjustment trimmer The output vo...

Страница 4: ...ired described as 100 240VAC 50 60Hz Output derating is required for AC input voltage less than 90VAC 4 2 Output Voltage Range Output voltage is set at the rated value Output voltage within the range specified can be adjusted by V ADJ trimmer Please set output voltage within specified adjustable range Turning the trimmer clockwise the output voltage will be increased Take note when the output volt...

Страница 5: ...d put protective diode in series to the output power line 4 5 Over Current Protection OCP Constant current limit with automatic recovery OCP function operates when the output current exceeds 105 of maximum DC output current of specification The outputs will be automatically recovered when the overload condition is removed Never operate the unit under over current or shorted conditions which may le...

Страница 6: ...t bypass diode 4 8 Parallel Operation A Operation to increase the output current is not possible B Operation as a Backup System Connect our reverse prevention module RP 60 20 or ORing diode to the output side of the product 1 Adjust each product output to same voltage The difference of each product output voltage should be within 5 2 Adjust the output voltage higher by the value of the voltage dro...

Страница 7: ... high impulse voltage at switch on and off timing Connect input and output as follows Input Output dotted line 3 0kVAC 1min 10mA Output terminal 500VAC 1min 20mA Input terminal solid line 2 0kVAC 1min 10mA Note1 In case of using external noise filter capacitance between Input and terminal might be increased When testing withstand voltage between Input and Output there is a possibility exceeding wi...

Страница 8: ...he output derating below load is percent of maximum output current value in a rated output voltage Convection Cooling The output derating below also can be used when input voltage is 170VAC 265VAC for the Mounting D or E 0 20 40 60 80 100 120 20 10 0 10 20 30 40 50 60 70 80 Load Ta 8 12 CN 1 INPUT CN 1 CN1 CN 1 FIN CN 1 FIN CN1 Mounting A Mounting B C Mounting D Mounting E Mounting D E Ta C 20 50 ...

Страница 9: ...se all mounting holes A for the product installation The vibration spec is specified under this mounting condition Please use mounting hole B as needed vibratility resistant improves 1 Mounting Holes size 5 holes φ3 5mm Allowable area by metal pieces is 9mm from each PCB corners Refer to figure below 9 12 Load 80 85 100 90 265 Input Voltage VAC Mounting A E Input Voltage VAC 85 90 265 80 Load Moun...

Страница 10: ...ce 3 must be connected to the Protective earth terminal of the equipment Also 2 mounting holes are must be connected to the Chassis Conductor by Metal spacer When screw clamping the mounting holes please use the screw with spring washer If not connect to the Chassis Conductor the conducted noise radiation noise and output noise will increase The location of 2 mounting holes for Chassis connection ...

Страница 11: ...ytic capacitor The life expectancy is not a guaranteed value please consider as a reference Do not use the product which passed over the life expectancy When keep using there is a risk of unexpected output shutdown or specifications may not be satisfied Please contact us for maintenance or exchange the product which passed over the life expectancy The life expectancy of the product is calculated i...

Страница 12: ...ADJ is properly adjusted 5 Check if the output current and output power does not over specifications 6 Audible noise can be heard when input voltage waveform is not sinusoidal wave 7 Audible noise can be heard during Dynamic Load operation 10 Warranty Period Warranty Period applies for Standard Mounting A and the number of output ON OFF is only once a day Do not exceed its derating of maximum load...