13. P

ROTECTION 

F

EATURES

 

Under voltage protection (UVP) 

Turn-On voltage 

Min. 
Typ.

Max. 

12.5Vdc 
13.0Vdc 

13.5Vdc 

For all models at 70% load, when UVLO 
pin is left open, can be adjusted with 

external resistor 

Under voltage protection (UVP) 

Shut-down voltage 

Min. 
Typ.

Max. 

10.5Vdc 
11.0Vdc 

11.5Vdc 

For all models at 70% load, 2V lock-out 

hysteresis voltage 

Input surge voltage 

Max.  180Vdc 

For maximal 100ms 

Output over voltage protection (OVP) 

Min. 
Typ.

Max. 

117% 
125% 

140% 

 

Output over-current protection (OCP) 

Min. 
Typ.

Max. 

110%  
125% 

140% 

Of nominal output current, intermittent 

operation (hiccup mode) 

Output short-circuit protection (SCP) 

 

Included 

Continuous, automatic recovery  

Over temperature protection (OTP) 

Typ. 

105°C 

Temperature at the centre part of base 
plate, non-latching, automatic recovery 

when temperature falls below 95°C 

Reverse input polarity protection 

 

Not included 

Use external protection diode if required 

Degree of pollution 

 

According to IEC 60664-1, not conductive 

 

Under-voltage control feature UVLO 

2 UVLO

6 -Vin

1 +Vin

PYH200

R

1

 (

A

dj

ust)

The PYH200 series has an adjustable under voltage lockout feature for the input 

voltage, which will shut down the converter according to following settings. 
 
 
 

Nominal input voltage 

DC 24V 

DC 36V 

DC 48V 

DC 72V 

DC 110V 

Turn-on voltage 

13.0V ±0.5V 

22.0V ±1.0V 

29.6V ±1.0V 

44.6V ±1.0V 

58.0V ±1.0V 

Shut-down voltage 

11.0V ±0.5V 

20.0V ±1.0V 

27.3V ±1.0V 

41.6V ±1.0V 

53.0V ±1.0V 

Resistor between pin 2 

and pin 6 

open 

62k

Ω

 34k

Ω

 18k

Ω

 10k

Ω

 

 

All parameters are typical values specified at nominal input voltage, nominal output load, 25°C ambient and after a 5 minutes run-in time unless  
otherwise noted. The information presented in this document is believed to be accurate and reliable and may change without notice. 

For additional information, please visit https://product.tdk.com/info/en/products/power/index.html 

11/21

DOC-ID: IM-PYH200-2022-05-04

 

Содержание PYH200 Series

Страница 1: ...16 Thermal Consideration and Derating 13 17 EMC Considerations 14 18 Remote ON OFF Function 16 19 Output Remote Sensing 16 20 Output Voltage Adjustment 17 21 Synchronizing the Switching Frequency 18...

Страница 2: ...Input to Output Isolation 14 160V 12 1 Wide range Input EN 50155 Railway Compliant IEC 62368 1 ICT Approved High Shock and Vibration Resistance Due to Potted Design Efficiency up to 90 40 to 100 C Op...

Страница 3: ...nction should occur during installation or operation immediately turn power off and send unit to the factory for inspection Install the device in an enclosure providing protection against electrical m...

Страница 4: ...ction In case of a high temperature the output shuts down and starts automatically after cooling off The device is equipped with under voltage protection on the input side If the input voltage is too...

Страница 5: ...to internal bus voltage can be used for hold up time purposes SYNC Control pin for frequency synchronization with external clock signal Sen Sen Sense lines for output voltage 7 RECOMMENDED WIRING SCH...

Страница 6: ...ter isolated 200W Input 14 160V Output 24V 8 4A half brick pcb mount PYH200 72WS48 DC DC converter isolated 200W Input 14 160V Output 48V 4 2A half brick pcb mount 9 SHORT FORM DATA Input voltage rang...

Страница 7: ...Max 95 RH No condensation allowed Altitude Max 5000m 16 400ft Atmospheric pressure a 110 54kP Vibration 20Hz 1kHz 0 04g2 Hz 6dB octave s ccording to MIL STD 810F 1 2kHz 60 minutes per axi A random vi...

Страница 8: ...ut load PYH200 72WS48 Efficiency and power losses vs output load All parameters are typical values specified at nominal input voltage nominal output load 25 C ambient and after a 5 minutes run in time...

Страница 9: ...ut 7 V Output 8 Sense 9 Trim 10 Sense 11 V Output All dimensions in inch mm Inch tolerances x xx 0 02 x xxx 0 01 Millimeter tolerances x x 0 5 x xx 0 25 Recommendation for pad design All parameters ar...

Страница 10: ...200Vdc Input to output A for 1 minute Min Min 3000Vac or 4200Vdc Input to base plate B for 1 minute Min Min 500Vac or 700Vdc Output to base plate C for 1 minute Isolation resistance Min 100 M Input to...

Страница 11: ...low 95 C Reverse input polarity protection Not included Use external protection diode if required Degree of pollution 2 According to IEC 60664 1 not conductive Under voltage control feature UVLO 2 UVL...

Страница 12: ...ad applications For details see application note for railway application EN 50155 Railway applications Rolling stock Electronic equipment EN 45545 2 Fire protection on railway vehicles Part 2 Requirem...

Страница 13: ...e curves apply in vertical mounting position with natural convection cooling or forced air cooling Power Dissipation without heatsink 0 0 100 C 20W Ambient Air Temperature 4W 8W 12W 16W 60 50 40 20 1...

Страница 14: ...Input with additional components see note 1 2kV Criterion A Surge voltage EN 61000 4 5 Input with additional components see note 1 2kV Criterion A Conducted disturbance EN 61000 4 6 0 15 80MHz 10V Cr...

Страница 15: ...2 C105 1812 X7R ceramic C103 C113 NIPPON CHEMI CON KXJ series aluminum capacitor or equivalent C106 Nichicon CS series aluminum capacitor or equivalent C114 NIPPON CHEMI CON KXJ series aluminum capaci...

Страница 16: ...ed by twisted pair wire or shield wire Output voltage might become unstable because of impedance of wiring and load condition when length of wire is exceeding 400mm Vout 11 PYH200 Vout 7 Sens 10 Sens...

Страница 17: ...r adjusting the 15V output model Output V 12 0 12 6 13 2 13 8 14 4 15V 15 45 15 9 16 35 16 8 17 25 20 16 12 8 4 3 6 9 12 15 R up 92820 40410 22940 14200 8960 R down 8640 16080 28470 53260 127620 Resis...

Страница 18: ...er output remains active after a loss of input power The DC DC converter itself is not capable of providing a hold time For this an external circuit with a large hold up storage capacitor is required...

Страница 19: ...out 7 Sens 10 Sens 8 TRIM 9 Load Vout 11 Vout 7 Sens 10 Sens 8 TRIM 9 C7 C6 R1 R2 D1 D2 Series operation for output voltages 6 Vin 1 Vin PYH200 5 Bus Vin Vin C1 C4 C2 L1 6 Vin 1 Vin PYH200 5 Bus C5 C3...

Страница 20: ...mm 4x 3 2mm 4x Thermal Pad 56 9 x 60 x 0 25mm 56 9 x 60 x 0 25mm 56 9 x 60 x 0 25mm Thermal impedance 3 90 C W nat convection 1 74 C W with 100LFM 1 33 C W with 200LFM 1 12 C W with 300LFM 0 97 C W wi...

Страница 21: ...n products power index html 26 CLEANING PROCESS AND SOLDERING PROFILE Cleaning process Clean the soldered side of the module with a brush prevent liquid from getting into the module Do not clean by so...

Отзывы: