5.  F

UNCTIONAL 

D

ESCRIPTION

 

The output is electronically protected against no-load, overload and short circuit. In case of an overload or 

short circuit, the device will operate intermittently (hiccup mode). 
The device can supply resistive and inductive loads. 
Avoid loads with large input capacitances. If the capacitive load is higher than the values specified, the device 

operates in an intermittent mode (hiccup mode). 
PYD20-72WS05: max. 

6800µF 

PYD20-72WS12: max. 

3300µF 

PYD20-72WS15: max. 

2200µF 

PYD20-72WD12: max. 

820µF 

PYD20-72WD15: max. 

680µF 

PYD20-72WD24: max. 

330µF 

The ± output voltage is generated by one converter. The sum of the two voltages is regulated. The power 

can be drawn asymmetrically but it is recommended that the less loaded output should take a minimum of 
5% of the total load. 
For single output voltage models, the output voltage can be adjusted with an external resistor connected 

between the TRIM-pin and the output voltage. 
The device is equipped with an over-temperature protection. In case of a high temperature, the output shuts 

down and starts automatically after cooling off. 
The device is equipped with under-voltage protection on the input side. If the input voltage is too low, the 
device does not start or switches off. 
In case of an internal defect, a redundant circuit prevents the output voltage from becoming excessive or 

dangerous (zener diode type protection). 
The device is equipped with a remote ON/OFF function. 
 

6.  F

UNCTIONAL 

D

IAGRAM

 

Input

+

-

Output

Output

Voltage

Adjust

OVP: Overvoltage,

OCP: Overcurrent,

SCP: Short-circuit

Protection

Input

Filter

(Pi-type)

Remote

ON/OFF

Output

Filter

Power

Converter

Output

Voltage

Regulator

+

-

1

2

6

3

5

4

RC

TRM

UVP:

Undervoltage

Protection

OTP: Over-

temperature

Protection

 

Input

+

-

Output

OVP: Overvoltage,

OCP: Overcurrent,

SCP: Short-circuit

Protection

Remote

ON/OFF

Output

Filter

Power

Converter

Output

Voltage

Regulator

+

-

1

2

6

3

4

5

RC

COM

UVP:

Undervoltage

Protection

OTP: Over-

temperature

Protection

Input

Filter

(Pi-type)

 

Functional diagram for models with a single output 

voltage 

 

Functional diagram for models with dual output voltages 

RC:

 Remote ON/OFF control pin 

TRM:

 Trim pin for output voltage adjustment 

Содержание PYD20 Series

Страница 1: ...11 13 Protection Features 11 14 Approvals and Regulatory Compliances 12 15 Rail Applications 12 16 Thermal Consideration and Derating 13 17 EMC Considerations 13 18 Remote ON OFF Function 15 19 Outpu...

Страница 2: ...mm Industry Standard Footprint 3000Vac Input to Output Isolation 8 5 160V 18 1 Wide range Input Single or Dual Output Voltages Available EN 50155 Railway Compliant IEC 62368 1 ICT Approved High Shock...

Страница 3: ...should occur during installation or operation immediately turn power off and send unit to the factory for inspection Install the device in an enclosure providing protection against electrical mechanic...

Страница 4: ...5 of the total load For single output voltage models the output voltage can be adjusted with an external resistor connected between the TRIM pin and the output voltage The device is equipped with an...

Страница 5: ...diode should be at least equal to the maximum possible input voltage Capacitor C1 and Diode D2 These two components provide higher transient resistance surge and burst at the input and are required if...

Страница 6: ...olated 20W Input 8 5 160V Output 15V 1 33A 2x1 inch pcb mount PYD20 72WD12 DC DC converter isolated 20W Input 8 5 160V Output 12V 0 83A 2x1 inch pcb mount PYD20 72WD15 DC DC converter isolated 20W Inp...

Страница 7: ...Altitude Max 5000m 16 400ft Atmospheric pressure 110 54kPa Vibration 20Hz 1kHz 0 04g2 Hz 1 2kHz 6dB octave 60 minutes per axis According to MIL STD 810F random vibration units are operational Shock 50...

Страница 8: ...ses vs output load PYD20 72WD12 Efficiency and power losses vs output load All parameters are typical values specified at nominal input voltage nominal output load 25 C ambient and after a 5 minutes r...

Страница 9: ...l parameters are typical values specified at nominal input voltage nominal output load 25 C ambient and after a 5 minutes run in time unless otherwise noted The information presented in this document...

Страница 10: ...Through hole 0 051 1 30 Top view pad 0 064 1 63 Bottom view pad 0 102 2 60 Pin assignment Pin Single output Dual outputs 1 V Input V Input 2 V Input V Input 3 V Output V Output 4 TRIM V Output 5 V Ou...

Страница 11: ...Input surge voltage Max 200Vdc For maximal 100ms Output over voltage protection OVP 6 2Vdc 15Vdc 18Vdc 15Vdc 18Vdc 30Vdc Zener diode type For 5V output For 12V output For 15V output For 12V output Fo...

Страница 12: ...e for railroad applications For details see application note for railway application EN 50155 Railway applications Rolling stock Electronic equipment EN 45545 2 Fire protection on railway vehicles Par...

Страница 13: ...dels 2 3 1 The derating is not hardware controlled The user has to take this into consideration to stay below the de rated current limits in order not to overload the unit 17 EMC CONSIDERATIONS In ter...

Страница 14: ...pacitor 120 F 220V NCC KXJ Aluminum capacitor 470pF 400Vac Y1 capacitor TDK CD series 1 5nF 400Vac Y1 capacitor TDK CD series 2 2nF 400Vac Y1 capacitor TDK CD series 1 4mH 0 4mmx1 13T ACME A151 T10x5x...

Страница 15: ...rent of 1mA typically 0 4mA to be activated The maximal allowed voltage open circuit voltage for this pin is 160Vdc Positive logic standard Converter ON open or 4 160V Converter FF closed or 0 1 2V 6...

Страница 16: ...2 36 12 72 13 08 13 44 13 8 20 16 12 8 4 3 6 9 12 15 R up 93820 37910 19270 9950 4360 R down 1550 8700 20630 44490 116060 Resistor values for adjusting the 15V output model Output V 12 0 12 6 13 2 13...

Страница 17: ...ed age TRIM 4 Vout 5 Vout 3 Load PYD 6 RC 2 Vin 1 Vin D1 C1 R1 D2 Vin Vin D2 To prevent the stored energy from flowing in the wrong direction and not being available for the DC DC converter Use only...

Отзывы: