BEFORE USING THE POWER SUPPLY UNIT 

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings 
before using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. 

 

DANGER

 

·

 

Never use this product in locations where flammable gas or ignitable substances are present. 

 

WARNING

 

·

 

Do  not touch  this product  or  its internal  components  while  circuit is  live,  or  shortly  after  shut down.  There  may  be  high 

voltage or high temperature present and you may receive an electric shock or burn.  

·

 

When the product is operating, keep your hands and face away from it as you may be injured by flying debris in the event 

of a fault. 

·

 

Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty. 

·

 

Do not use this product in the event of the emission of smoke or abnormal smell and sound etc. It might lead to fire and/or 

electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the user. 

·

 

Do not operate these products in the presence of condensation. It might lead to fire and/or electric shock. 

 

 

·

 

Do not drop or insert anything into the product. It might lead to a failure, fire and/or electric shock.

 

 

CAUTION

 

 

·

 

This power supply is designed for use within an end product such that it is accessible to SERVICE ENGINEERS only. 

·

 

Confirm connections to input/output terminals and signal terminals are correct as indicated in the instruction manual before 

switching on. 

·

 

Input voltage, Output current, Output power, Base-plate temperature, ambient temperature and ambient humidity should be 

kept within specifications, otherwise the product will be damaged or malfunctioned. 

·

 

Do  not  operate  and  store  this  product  in  an  environment  where  condensation  might  occur.  In  such  case,  waterproof 

treatment is necessary. 

·

 

Never operate the unit under over current or shorted conditions for 30 seconds or more and out of Input Voltage Range as 

specification. Insulation failure, smoking, burning or other damage might occur to the unit. 

·

 

Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances.

 

 

·

 

For  applications  which  require  very  high  reliability  (Nuclear  related  equipment,  traffic  control  equipment,  etc.),  it  is 

necessary to provide a fail safe mechanism in the end equipment. 

·

 

The information  in  this  document  is  subject to  change  without  prior  notice.  Please  refer  to  the latest  version  of  the  data 

sheet, etc., for the most up-to date specifications of the product. 

·

 

No part of this document may be copied or reproduced in any form without prior written consent of TDK-Lambda. 

·

 

Do not inject abnormal voltages into the output or signal of this product. The injection of reverse voltage or over voltage 

exceeding nominal output voltage into the output or signal terminals might cause damage to internal components. 

·

 

Operation of this product under over-current or short circuit conditions can result in damage. Failures of the product under 

these conditions have been assessed and are considered to be safe within the meaning of IEC/UL/CSA 60950-1. 

·

 

On the occasion of obtain of Safety Standard, this power supply is not considered for connect bVin terminal and 

earth.   

·

 

In order to maintain SELV output, the base-plate must be protectively earthed in the end application. Where the base-plate 

is not earthed, the output must be considered hazardous and must not be made user accessible. 

·

 

The output of this product may, under fault conditions, exceed SELV voltage limits. Therefore the output must be earthed 

in the end equipment to maintain SELV. If the output is not earthed, they must be considered hazardous and must not be 
made user accessible. 

·

 

The  application  circuits  and their  parameters  are  for reference  only.  Be  sure to  verify  effectiveness  of  these  circuits and 

their parameters before finalizing the circuit design. 

·

 

Use  an  external  fuse  to  each  module  to  ensure  safe  operation  and  compliance  with  the  Safety  Standards  to  which  it  is 

approved. Moreover, it is necessary to use fast-blow type when selecting fuse. 

Содержание PH-A280 Series

Страница 1: ...ent or shorted conditions for 30 seconds or more and out of Input Voltage Range as specification Insulation failure smoking burning or other damage might occur to the unit Do not use this product in e...

Страница 2: ...Lambda PH A280 Series INSTRUCTION MANUAL Note CE MARKING CE Marking when applied to a product covered by this handbook indicates compliance with the low voltage directive 2006 95 EC in that it compli...

Страница 3: ...1 1 TDK Lambda PH A280 Series INSTRUCTION MANUAL 1 Block Diagram 2 Sequence Time Chart...

Страница 4: ...4 Terminal Explanation Vin CNT Vin V S TRM S V Base plate can be connected to FG Frame Ground by M3 threaded holes Connect Vin Vin V V with consideration of contact resistance 1 There is no terminal...

Страница 5: ...al components according to Fig 5 1 Pay attention to the each wiring If it is connected to wrong terminal the power supply will be damaged PH A280 series employs conduction cooling method Use heat sink...

Страница 6: ...terminals Take note that in case of large equivalent series resistance especially operation at low ambient temperature Power supply output might not shut down normally Recommended Capacitor Value 22 F...

Страница 7: ...eramic capacitor as close as possible to the terminals of the power supply in order to reduce output spike noise voltage Recommended 2 2 F Take note that PCB wiring design might influence output spike...

Страница 8: ...d cause power supply damage For cases where reverse connections are possible connect a protective diode and fuse Use protective diode with higher voltage rating than the input voltage and with higher...

Страница 9: ...nsitionally Moreover maximum value and minimum value of input voltage waveform must not go beyond the limit of above input voltage range InputVotage Range Input Voltage Fig 6 1 Input Ripple Voltage 6...

Страница 10: ...nal Fig 6 2 Connection for Output Voltage Trim Down 1 3 Equation of external resistor and output voltage Radj down External adjustment resistor Output voltage change rate against nominal output voltag...

Страница 11: ...j up between TRM terminal and S terminal Fig 6 4 Connection for Output Voltage Trim Up 2 3 Equation of external resistor and output voltage Radj up External adjustment resistor Output voltage change r...

Страница 12: ...urrent of specification 3 2 External resister connecting method External resistance Rex is connected between TRM terminal and S terminal and variable resistor VR is connected between S terminal and V...

Страница 13: ...input voltage is gradually varied steady state within specified input voltage range 6 5 Maximum Load Regulation Maximum value of output voltage change when output current is gradually varied steady st...

Страница 14: ...ficiently and recycle output either by recycling the input line after dropping down to 0V or reset by ON OFF control function However take note that OTP will operate again unless the cause of abnormal...

Страница 15: ...long wiring for prevention of noise attach about 0 1uF capacitor between CNT terminal and Vin terminal 3 At L level source current from CNT terminal to Vin terminal is 0 2mA 0 3mA 4 The maximum CNT te...

Страница 16: ...ower Fig 6 13 Redundant Operation Connection Note In redundant operation the remote sensing cannot be done 6 13 Parallel Operation Parallel Operation cannot be used 6 14 Series Operation Series operat...

Страница 17: ...d at a point 10 mm or less from the power supply side Use below 85 ambient temperature Fig 6 16 Measurement Point of Fig 6 17 Derating Curve Base plate Temperature To further improve reliability it is...

Страница 18: ...f of the testing equipment when applying or when shutting down the test voltage Instead gradually increase or decrease the applied voltage Take note especially not to use the timer of the test equipme...

Страница 19: ...pply might be damaged Formula for calculating total capacitance between Output terminal and FG terminal C6 C7 5 C2 C5 21250 pF Fig 6 21 Example of connecting external application 6 21 Isolation Resist...

Страница 20: ...M3 screws and mount it to the M3 threaded holes of the power module Recommended torque is 0 54N m 2 Mounting Holes Mounting holes of the power supply are connected to base plate Connect base plate to...

Страница 21: ...en heatsink and base plate to minimize the contact thermal resistance and to enhance the heat conductivity Also use the no warped heatsink and make sure good contact between base plate and heatsink 2...

Страница 22: ...t voltage applied Are the remote sensing terminals S S correctly connected Is the measurement done at the sensing points For cases where output voltage adjustment is used is the resistor or variable r...

Страница 23: ...INSTRUCTION MANUAL 10 Option Heatsink 1 at convection cooling 10 1 For PH A280 1 HAQ 10T Convection cooling Thermal resistance 7 5 W Forced air cooling 3 3 5 Thermal resistance between Heatsink and am...